Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN6P610T215 — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN6P610T215 is a 215.0 W STC (191.3 W PTC) Multi-c-Si solar module ranking #20,859 of 21,677 CEC listings (below all-CEC median; higher than 3.5% of peers). It delivers 13.13% efficiency, 36.0 V Voc at 25 C, and 40.21 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
215.0 W
PTC Wattage
191.3 W
Voc @ 25C
36.0 V
Efficiency
13.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN6P610T215 Compare Against Peer CEC Listings?

Engineering position of Auxin Solar AXN6P610T215 (215.0 W STC) vs. Advance Power API-P215 across 1,407 CEC Multi-c-Si solar modules.

Ranking #20,859 across 21,677 CEC solar panels (below all-CEC median; higher than 3.5% of peers), Auxin Solar AXN6P610T215 operates as a compact residential or specialty off-grid module sitting 63.8 W below the 278.8 W Multi-c-Si median. Lower 36.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 89.0% PTC-to-STC thermal output (191.3 W real-world rating), 38 panels occupy 670 sq ft and offset roughly $2,045/yr at average US rates (or $3,458/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Auxin Solar AXN6P610T215 Fall Across Listed CEC Models?

Plots Auxin Solar AXN6P610T215 at 215.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN6P610T215 (215.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN6P6: 215.0 W

What Dataset Percentiles Define Auxin Solar AXN6P610T215?

Benchmarks Auxin Solar AXN6P610T215 on STC wattage, thermal PTC/STC retention, and 13.13 aperture conversion efficiency against CEC peers.

Auxin Solar AXN6P610T215 Engineering BenchmarksPercentile comparison of Auxin Solar AXN6P610T215 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage215.0 WPTC/STC Retention89.0%Module Efficiency13.13%

What Do the Dataset Ranks Show for Auxin Solar AXN6P610T215?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN6P610T215 by Auxin Solar.

Rank #20,859 / 21,677

215.0 W STC · Higher Than 3.5%

215.0 W STC (-170.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,376

13.13% Aperture Efficiency

Power density 131.3 W/m2 (6.78 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.21 V at -10 C (562.9 V string) and 41.41 V at -20 C (14 max).

8 kW Reference Array

38 Panels = 8,170 W STC

Occupies 62.2 m2 (670 sq ft) producing 7,269 W PTC; NEC 690.8 OCPD floor is 12.21 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.0 * (1 + (-0.334/100) * (-10 - 25)) = 40.21 V | OCPD = 1.56 * 7.83 = 12.21 A

Inputs from CEC Modules.csv for Auxin Solar AXN6P610T215: Voc=36.0 V, beta_Voc=-0.334%/C, Isc=7.83 A, STC=215.0 W, Area=1.638 m2.

Result: 14 panels max on 600 V (562.9 V); 38 panels for 8 kW (670 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN6P610T215?

Laboratory test ratings recorded for Auxin Solar AXN6P610T215 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN6P610T215.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 215.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 191.3 W (89.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.83 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.94 V / 7.18 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.334 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.13% (1.638 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Auxin Solar AXN6P610T215 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (670 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN6P610T215.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 28 6.02 kW 494 sq ft $1,507 $2,548
8 kW Class 38 8.17 kW 670 sq ft $2,045 $3,458
10 kW Class 47 10.11 kW 829 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Sibling wattage bins and frame colors grouped with Auxin Solar AXN6P610T215 under Auxin Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Auxin Solar AXN6P610T215 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN6P610T210 210.0 W 186.8 W 35.94 V 29.64 V 12.82%
Auxin Solar AXN6P610T215 215.0 W 191.3 W 36.0 V 29.94 V 13.13%
Auxin Solar AXN6P610T220 220.0 W 195.9 W 36.06 V 30.12 V 13.43%

How Many Auxin Solar AXN6P610T215 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Auxin Solar AXN6P610T215 (beta_Voc -0.334%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.0V and beta_Voc=-0.334%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.41 V 14 panels 579.7 V 24 panels
-10 C (14 F) 40.21 V 14 panels 562.9 V 24 panels
0 C (32 F) 39.01 V 15 panels 585.1 V 25 panels
25 C (77 F STC) 36.0 V 16 panels 576.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6P610T215?

Closest cross-brand CEC competitors to Auxin Solar AXN6P610T215 matched near 215.0 W STC and 36.0 V Voc, led by Advance Power API-P215.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P215
Advance Power
215.0 W Tie (0 W) 36.0 V 13.13% 89.0%
Anji Dasol Solar Energy Science & Technology DS-A4-215
Anji Dasol Solar Energy Science & Technology
215.0 W Tie (0 W) 36.3 V 13.06% 87.1%
Anhui Rinengzhongtian Semiconductor Development QJP215-60
Anhui Rinengzhongtian Semiconductor Development
215.0 W Tie (0 W) 35.4 V 13.22% 89.1%
APOS Energy AP215
APOS Energy
215.0 W Tie (0 W) 36.79 V 12.96% 88.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6P610T215?

Evaluate Auxin Solar AXN6P610T215 (215.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6P610T215 reaches 41.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 38 panels for an 8 kW build require 670 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (670 sq ft).
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6P610T215 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN6P610T215 8 kW Residential Fit

Needs 38 modules (670 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Advance Power API-P215.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 191.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN6P610T215 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Auxin Solar AXN6P610T215 panels fit on a 600 V winter solar string?

At -10 C (14 F), Auxin Solar AXN6P610T215 cold Voc rises from 36.0 V to 40.21 V (beta_Voc -0.334%/C), capping a 600 V string at 14 panels (562.9 V).

How much roof area does an 8 kW array of Auxin Solar AXN6P610T215 need?

An 8 kW DC system uses 38 Auxin Solar AXN6P610T215 modules (8,170 W STC / 7,269 W PTC), covering roughly 670 sq ft and saving ~$2,045/yr at 18.54 c/kWh.

How does Auxin Solar AXN6P610T215 compare against Advance Power API-P215?

Auxin Solar AXN6P610T215 outputs 215.0 W STC (36.0 V Voc, rank #20,859 of 21,677), while Advance Power API-P215 delivers 215.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.