Advance Power API-P215 is a 215.0 W STC (191.3 W PTC) Multi-c-Si solar module ranking #20,859 of 21,677 CEC listings (below all-CEC median; higher than 3.5% of peers). It delivers 13.13% efficiency, 36.0 V Voc at 25 C, and 40.21 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 215.0 W
- PTC Wattage
- 191.3 W
- Voc @ 25C
- 36.0 V
- Efficiency
- 13.13%
How Does Advance Power API-P215 Compare Against Peer CEC Listings?
Engineering position of Advance Power API-P215 (215.0 W STC) vs. Auxin Solar AXN6P610T215 across 1,407 CEC Multi-c-Si solar modules.
Ranking #20,859 across 21,677 CEC solar panels (below all-CEC median; higher than 3.5% of peers), Advance Power API-P215 operates as a compact residential or specialty off-grid module sitting 63.8 W below the 278.8 W Multi-c-Si median. Lower 36.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 89.0% PTC-to-STC thermal output (191.3 W real-world rating), 38 panels occupy 670 sq ft and offset roughly $2,045/yr at average US rates (or $3,458/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Advance Power API-P215 Fall Across Listed CEC Models?
Plots Advance Power API-P215 at 215.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Advance Power API-P215?
Benchmarks Advance Power API-P215 on STC wattage, thermal PTC/STC retention, and 13.13 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Advance Power API-P215?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Advance Power API-P215 by Advance Power.
215.0 W STC · Higher Than 3.5%
215.0 W STC (-170.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.13% Aperture Efficiency
Power density 131.3 W/m2 (6.78 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.21 V at -10 C (562.9 V string) and 41.41 V at -20 C (14 max).
38 Panels = 8,170 W STC
Occupies 62.2 m2 (670 sq ft) producing 7,269 W PTC; NEC 690.8 OCPD floor is 12.21 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.0 * (1 + (-0.334/100) * (-10 - 25)) = 40.21 V | OCPD = 1.56 * 7.83 = 12.21 A
Inputs from CEC Modules.csv for Advance Power API-P215: Voc=36.0 V, beta_Voc=-0.334%/C, Isc=7.83 A, STC=215.0 W, Area=1.638 m2.
Result: 14 panels max on 600 V (562.9 V); 38 panels for 8 kW (670 sq ft).
What Are the Published CEC Specifications for Advance Power API-P215?
Laboratory test ratings recorded for Advance Power API-P215 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 215.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 191.3 W (89.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.94 V / 7.18 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.334 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.13% (1.638 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Advance Power API-P215 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (670 sq ft at 8 kW), and estimated Year-1 electric bill offset for Advance Power API-P215.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.02 kW | 494 sq ft | $1,507 | $2,548 |
| 8 kW Class | 38 | 8.17 kW | 670 sq ft | $2,045 | $3,458 |
| 10 kW Class | 47 | 10.11 kW | 829 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Advance Power Series?
Sibling wattage bins and frame colors grouped with Advance Power API-P215 under Advance Power to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Advance Power API-P210 | 210.0 W | 186.8 W | 35.94 V | 29.64 V | 12.82% |
| Advance Power API-P215 | 215.0 W | 191.3 W | 36.0 V | 29.94 V | 13.13% |
| Advance Power API-P220 | 220.0 W | 195.9 W | 36.06 V | 30.12 V | 13.43% |
How Many Advance Power API-P215 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Advance Power API-P215 (beta_Voc -0.334%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.41 V | 14 panels | 579.7 V | 24 panels |
| -10 C (14 F) | 40.21 V | 14 panels | 562.9 V | 24 panels |
| 0 C (32 F) | 39.01 V | 15 panels | 585.1 V | 25 panels |
| 25 C (77 F STC) | 36.0 V | 16 panels | 576.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Advance Power API-P215?
Closest cross-brand CEC competitors to Advance Power API-P215 matched near 215.0 W STC and 36.0 V Voc, led by Auxin Solar AXN6P610T215.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6P610T215 Auxin Solar |
215.0 W | Tie (0 W) | 36.0 V | 13.13% | 89.0% |
| Anji Dasol Solar Energy Science & Technology DS-A4-215 Anji Dasol Solar Energy Science & Technology |
215.0 W | Tie (0 W) | 36.3 V | 13.06% | 87.1% |
| Anhui Rinengzhongtian Semiconductor Development QJP215-60 Anhui Rinengzhongtian Semiconductor Development |
215.0 W | Tie (0 W) | 35.4 V | 13.22% | 89.1% |
| APOS Energy AP215 APOS Energy |
215.0 W | Tie (0 W) | 36.79 V | 12.96% | 88.8% |
What Are the Design Limits and Best-Fit Uses for Advance Power API-P215?
Evaluate Advance Power API-P215 (215.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Advance Power API-P215 reaches 41.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 38 panels for an 8 kW build require 670 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (670 sq ft).
- 2026 tax credit baseline: cash residential installs of Advance Power API-P215 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Advance Power API-P215 8 kW Residential Fit
Needs 38 modules (670 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN6P610T215.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 191.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Advance Power API-P215 by Advance Power grounded in CEC test data and NEC 690.7/690.8 limits.
How many Advance Power API-P215 panels fit on a 600 V winter solar string?
At -10 C (14 F), Advance Power API-P215 cold Voc rises from 36.0 V to 40.21 V (beta_Voc -0.334%/C), capping a 600 V string at 14 panels (562.9 V).
How much roof area does an 8 kW array of Advance Power API-P215 need?
An 8 kW DC system uses 38 Advance Power API-P215 modules (8,170 W STC / 7,269 W PTC), covering roughly 670 sq ft and saving ~$2,045/yr at 18.54 c/kWh.
How does Advance Power API-P215 compare against Auxin Solar AXN6P610T215?
Advance Power API-P215 outputs 215.0 W STC (36.0 V Voc, rank #20,859 of 21,677), while Auxin Solar AXN6P610T215 delivers 215.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)