Anhui Rinengzhongtian Semiconductor Development QJP215-60 is a 215.0 W STC (191.5 W PTC) Multi-c-Si solar module ranking #20,859 of 21,677 CEC listings (below all-CEC median; higher than 3.5% of peers). It delivers 13.22% efficiency, 35.4 V Voc at 25 C, and 39.87 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 215.0 W
- PTC Wattage
- 191.5 W
- Voc @ 25C
- 35.4 V
- Efficiency
- 13.22%
How Does Anhui Rinengzhongtian Semiconductor Development QJP215-60 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Anhui Rinengzhongtian Semiconductor Development QJP215-60 (Multi-c-Si) residential solar systems.
Anhui Rinengzhongtian Semiconductor Development QJP215-60 delivers 132.1 W/m2 (6.69 percentage points below 19.91% CEC median) and typical 89.1% PTC-to-STC thermal output (191.5 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (665 sq ft). At -4 F (-20 C), string voltage climbs to 41.15 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Advance Power API-P215 (215.0 W).
Where Does Anhui Rinengzhongtian Semiconductor Development QJP215-60 Fall Across Listed CEC Models?
Comparison of Anhui Rinengzhongtian Semiconductor Development QJP215-60 (215.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Anhui Rinengzhongtian Semiconductor Development QJP215-60?
Relative ranking of Anhui Rinengzhongtian Semiconductor Development QJP215-60 across nameplate watts, 89.1% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Anhui Rinengzhongtian Semiconductor Development QJP215-60?
Summary of Anhui Rinengzhongtian Semiconductor Development QJP215-60 output rank, 8 kW array size (38 panels), efficiency rating, and 600 V string limit.
215.0 W STC · Higher Than 3.5%
215.0 W STC (-170.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.22% Aperture Efficiency
Power density 132.1 W/m2 (6.69 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 39.87 V at -10 C (598.0 V string) and 41.15 V at -20 C (14 max).
38 Panels = 8,170 W STC
Occupies 61.8 m2 (665 sq ft) producing 7,277 W PTC; NEC 690.8 OCPD floor is 12.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 35.4 * (1 + (-0.361/100) * (-10 - 25)) = 39.87 V | OCPD = 1.56 * 8.16 = 12.73 A
Inputs from CEC Modules.csv for Anhui Rinengzhongtian Semiconductor Development QJP215-60: Voc=35.4 V, beta_Voc=-0.361%/C, Isc=8.16 A, STC=215.0 W, Area=1.627 m2.
Result: 15 panels max on 600 V (598.0 V); 38 panels for 8 kW (665 sq ft).
What Are the Published CEC Specifications for Anhui Rinengzhongtian Semiconductor Development QJP215-60?
Complete CEC test sheet for Anhui Rinengzhongtian Semiconductor Development QJP215-60 including Isc (8.16 A), Voc (35.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 215.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 191.5 W (89.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 35.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.5 V / 7.29 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.361 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.22% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Anhui Rinengzhongtian Semiconductor Development QJP215-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Anhui Rinengzhongtian Semiconductor Development QJP215-60.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.02 kW | 490 sq ft | $1,507 | $2,548 |
| 8 kW Class | 38 | 8.17 kW | 665 sq ft | $2,045 | $3,458 |
| 10 kW Class | 47 | 10.11 kW | 823 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Anhui Rinengzhongtian Semiconductor Development Series?
Related Anhui Rinengzhongtian Semiconductor Development power steps and black/silver trims consolidated into this Anhui Rinengzhongtian Semiconductor Development QJP215-60 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJP205-60 | 205.0 W | 182.3 W | 35.1 V | 29.3 V | 12.6% |
| Anhui Rinengzhongtian Semiconductor Development QJP210-60 | 210.0 W | 186.9 W | 35.2 V | 29.4 V | 12.91% |
| Anhui Rinengzhongtian Semiconductor Development QJP215-60 | 215.0 W | 191.5 W | 35.4 V | 29.5 V | 13.22% |
| Anhui Rinengzhongtian Semiconductor Development QJP220-60 | 220.0 W | 196.0 W | 35.4 V | 29.5 V | 13.52% |
How Many Anhui Rinengzhongtian Semiconductor Development QJP215-60 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Anhui Rinengzhongtian Semiconductor Development QJP215-60 (35.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.15 V | 14 panels | 576.1 V | 24 panels |
| -10 C (14 F) | 39.87 V | 15 panels | 598.0 V | 25 panels |
| 0 C (32 F) | 38.59 V | 15 panels | 578.9 V | 25 panels |
| 25 C (77 F STC) | 35.4 V | 16 panels | 566.4 V | 28 panels |
Which Cross-Brand Solar Modules Compare Closest to Anhui Rinengzhongtian Semiconductor Development QJP215-60?
Four comparable CEC modules such as Advance Power API-P215 (215.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P215 Advance Power |
215.0 W | Tie (0 W) | 36.0 V | 13.13% | 89.0% |
| Auxin Solar AXN6P610T215 Auxin Solar |
215.0 W | Tie (0 W) | 36.0 V | 13.13% | 89.0% |
| Anji Dasol Solar Energy Science & Technology DS-A4-215 Anji Dasol Solar Energy Science & Technology |
215.0 W | Tie (0 W) | 36.3 V | 13.06% | 87.1% |
| APOS Energy AP215 APOS Energy |
215.0 W | Tie (0 W) | 36.79 V | 12.96% | 88.8% |
What Are the Design Limits and Best-Fit Uses for Anhui Rinengzhongtian Semiconductor Development QJP215-60?
Evaluate Anhui Rinengzhongtian Semiconductor Development QJP215-60 (215.0 W STC, 35.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Anhui Rinengzhongtian Semiconductor Development QJP215-60 reaches 41.15 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 38 panels for an 8 kW build require 665 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (665 sq ft).
- 2026 tax credit baseline: cash residential installs of Anhui Rinengzhongtian Semiconductor Development QJP215-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Anhui Rinengzhongtian Semiconductor Development QJP215-60 8 kW Residential Fit
Needs 38 modules (665 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare Advance Power API-P215.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 191.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Anhui Rinengzhongtian Semiconductor Development QJP215-60 by Anhui Rinengzhongtian Semiconductor Development grounded in CEC test data and NEC 690.7/690.8 limits.
How many Anhui Rinengzhongtian Semiconductor Development QJP215-60 panels fit on a 600 V winter solar string?
At -10 C (14 F), Anhui Rinengzhongtian Semiconductor Development QJP215-60 cold Voc rises from 35.4 V to 39.87 V (beta_Voc -0.361%/C), capping a 600 V string at 15 panels (598.0 V).
How much roof area does an 8 kW array of Anhui Rinengzhongtian Semiconductor Development QJP215-60 need?
An 8 kW DC system uses 38 Anhui Rinengzhongtian Semiconductor Development QJP215-60 modules (8,170 W STC / 7,277 W PTC), covering roughly 665 sq ft and saving ~$2,045/yr at 18.54 c/kWh.
How does Anhui Rinengzhongtian Semiconductor Development QJP215-60 compare against Advance Power API-P215?
Anhui Rinengzhongtian Semiconductor Development QJP215-60 outputs 215.0 W STC (35.4 V Voc, rank #20,859 of 21,677), while Advance Power API-P215 delivers 215.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)