Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG165M is a 165.0 W STC (146.0 W PTC) Mono-c-Si solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 12.92% efficiency, 42.5 V Voc at 25 C, and 47.96 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
165.0 W
PTC Wattage
146.0 W
Voc @ 25C
42.5 V
Efficiency
12.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG165M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SG165M (Mono-c-Si) residential solar systems. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

PEIMAR SG165M delivers 129.2 W/m2 (6.99 percentage points below 19.91% CEC median) and typical 88.5% PTC-to-STC thermal output (146.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft). At -4 F (-20 C), string voltage climbs to 49.52 V per unit, capping 600 V circuits at 12 panels. Compare specs directly with Anhui Rinengzhongtian Semiconductor Development QJM165-72 (165.0 W).

Where Does PEIMAR SG165M Fall Across Listed CEC Models?

Comparison of PEIMAR SG165M (165.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG165M (165.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG165M: 165.0 W

What Dataset Percentiles Define PEIMAR SG165M?

Relative ranking of PEIMAR SG165M across nameplate watts, 88.5% PTC thermal ratio, and module aperture efficiency. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

PEIMAR SG165M Engineering BenchmarksPercentile comparison of PEIMAR SG165M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage165.0 WPTC/STC Retention88.5%Module Efficiency12.92%

What Do the Dataset Ranks Show for PEIMAR SG165M?

Summary of PEIMAR SG165M output rank, 8 kW array size (49 panels), efficiency rating, and 600 V string limit.

Rank #21,351 / 21,677

165.0 W STC · Higher Than 1.4%

165.0 W STC (-220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,422

12.92% Aperture Efficiency

Power density 129.2 W/m2 (6.99 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.96 V at -10 C (575.5 V string) and 49.52 V at -20 C (12 max).

8 kW Reference Array

49 Panels = 8,085 W STC

Occupies 62.6 m2 (674 sq ft) producing 7,154 W PTC; NEC 690.8 OCPD floor is 8.14 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.5 * (1 + (-0.367/100) * (-10 - 25)) = 47.96 V | OCPD = 1.56 * 5.22 = 8.14 A

Inputs from CEC Modules.csv for PEIMAR SG165M: Voc=42.5 V, beta_Voc=-0.367%/C, Isc=5.22 A, STC=165.0 W, Area=1.277 m2.

Result: 12 panels max on 600 V (575.5 V); 49 panels for 8 kW (674 sq ft).

What Are the Published CEC Specifications for PEIMAR SG165M?

Complete CEC test sheet for PEIMAR SG165M including Isc (5.22 A), Voc (42.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG165M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 165.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 146.0 W (88.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.22 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.4 V / 4.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.367 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.92% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SG165M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SG165M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 37 6.11 kW 509 sq ft $1,529 $2,586
8 kW Class 49 8.09 kW 674 sq ft $2,025 $3,424
10 kW Class 61 10.06 kW 838 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SG165M series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the PEIMAR SG165M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG160M 160.0 W 141.5 W 42.42 V 35.01 V 12.53%
PEIMAR SG165M 165.0 W 146.0 W 42.5 V 35.4 V 12.92%
PEIMAR SG170M 170.0 W 150.5 W 42.7 V 35.6 V 13.32%

How Many PEIMAR SG165M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PEIMAR SG165M (42.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=42.5V and beta_Voc=-0.367%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.52 V 12 panels 594.2 V 20 panels
-10 C (14 F) 47.96 V 12 panels 575.5 V 20 panels
0 C (32 F) 46.4 V 12 panels 556.8 V 21 panels
25 C (77 F STC) 42.5 V 14 panels 595.0 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG165M?

Four comparable CEC modules such as Anhui Rinengzhongtian Semiconductor Development QJM165-72 (165.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJM165-72
Anhui Rinengzhongtian Semiconductor Development
165.0 W Tie (0 W) 42.5 V 12.92% 88.5%
Juli New Energy JLS165M
Juli New Energy
165.0 W Tie (0 W) 42.0 V 12.92% 85.8%
Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B
Hanwha Qcells (Qidong) Co Ltd
165.0 W Tie (0 W) 44.0 V 12.92% 90.1%
JA Solar JAM5-72-165
JA Solar
165.0 W Tie (0 W) 44.79 V 12.92% 89.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG165M?

Evaluate PEIMAR SG165M (165.0 W STC, 42.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG165M reaches 49.52 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 49 panels for an 8 kW build require 674 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG165M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG165M 8 kW Residential Fit

Needs 49 modules (674 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM165-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 146.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG165M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

How many PEIMAR SG165M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SG165M cold Voc rises from 42.5 V to 47.96 V (beta_Voc -0.367%/C), capping a 600 V string at 12 panels (575.5 V).

How much roof area does an 8 kW array of PEIMAR SG165M need?

An 8 kW DC system uses 49 PEIMAR SG165M modules (8,085 W STC / 7,154 W PTC), covering roughly 674 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

How does PEIMAR SG165M compare against Anhui Rinengzhongtian Semiconductor Development QJM165-72?

PEIMAR SG165M outputs 165.0 W STC (42.5 V Voc, rank #21,351 of 21,677), while Anhui Rinengzhongtian Semiconductor Development QJM165-72 delivers 165.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.