Skip to main content
WireAndSun
Calculators
CEC PV Module

Anhui Rinengzhongtian Semiconductor Development QJM165-72 — CEC Solar Module Specifications

Manufacturer: Anhui Rinengzhongtian Semiconductor Development Registry: CEC Verified Engineering Specification

Anhui Rinengzhongtian Semiconductor Development QJM165-72 is a 165.0 W STC (146.0 W PTC) Mono-c-Si solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 12.92% efficiency, 42.5 V Voc at 25 C, and 47.96 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
165.0 W
PTC Wattage
146.0 W
Voc @ 25C
42.5 V
Efficiency
12.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Anhui Rinengzhongtian Semiconductor Development QJM165-72 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Anhui Rinengzhongtian Semiconductor Development QJM165-72 (Mono-c-Si) residential solar systems.

Homeowners evaluating Anhui Rinengzhongtian Semiconductor Development QJM165-72 need 37 panels for 6 kW or 49 panels (674 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft). Under NEC 690.7(A), beta_Voc (-0.367%/C) pushes open-circuit voltage to 47.96 V at 14 F and 49.52 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Anhui Rinengzhongtian Semiconductor Development QJM165-72 Fall Across Listed CEC Models?

Comparison of Anhui Rinengzhongtian Semiconductor Development QJM165-72 (165.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Anhui Rinengzhongtian Semiconductor Development QJM165-72 (165.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAnhui Rinengzhongt: 165.0 W

What Dataset Percentiles Define Anhui Rinengzhongtian Semiconductor Development QJM165-72?

Relative ranking of Anhui Rinengzhongtian Semiconductor Development QJM165-72 across nameplate watts, 88.5% PTC thermal ratio, and module aperture efficiency.

Anhui Rinengzhongtian Semiconductor Development QJM165-72 Engineering BenchmarksPercentile comparison of Anhui Rinengzhongtian Semiconductor Development QJM165-72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage165.0 WPTC/STC Retention88.5%Module Efficiency12.92%

What Do the Dataset Ranks Show for Anhui Rinengzhongtian Semiconductor Development QJM165-72?

Summary of Anhui Rinengzhongtian Semiconductor Development QJM165-72 output rank, 8 kW array size (49 panels), efficiency rating, and 600 V string limit.

Rank #21,351 / 21,677

165.0 W STC · Higher Than 1.4%

165.0 W STC (-220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,422

12.92% Aperture Efficiency

Power density 129.2 W/m2 (6.99 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.96 V at -10 C (575.5 V string) and 49.52 V at -20 C (12 max).

8 kW Reference Array

49 Panels = 8,085 W STC

Occupies 62.6 m2 (674 sq ft) producing 7,154 W PTC; NEC 690.8 OCPD floor is 8.14 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.5 * (1 + (-0.367/100) * (-10 - 25)) = 47.96 V | OCPD = 1.56 * 5.22 = 8.14 A

Inputs from CEC Modules.csv for Anhui Rinengzhongtian Semiconductor Development QJM165-72: Voc=42.5 V, beta_Voc=-0.367%/C, Isc=5.22 A, STC=165.0 W, Area=1.277 m2.

Result: 12 panels max on 600 V (575.5 V); 49 panels for 8 kW (674 sq ft).

What Are the Published CEC Specifications for Anhui Rinengzhongtian Semiconductor Development QJM165-72?

Complete CEC test sheet for Anhui Rinengzhongtian Semiconductor Development QJM165-72 including Isc (5.22 A), Voc (42.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Anhui Rinengzhongtian Semiconductor Development QJM165-72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 165.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 146.0 W (88.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.22 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.4 V / 4.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.367 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.92% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Anhui Rinengzhongtian Semiconductor Development QJM165-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Anhui Rinengzhongtian Semiconductor Development QJM165-72.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 37 6.11 kW 509 sq ft $1,529 $2,586
8 kW Class 49 8.09 kW 674 sq ft $2,025 $3,424
10 kW Class 61 10.06 kW 838 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This Anhui Rinengzhongtian Semiconductor Development Series?

Related Anhui Rinengzhongtian Semiconductor Development power steps and black/silver trims consolidated into this Anhui Rinengzhongtian Semiconductor Development QJM165-72 series guide.

Sibling CEC listings grouped into the Anhui Rinengzhongtian Semiconductor Development QJM165-72 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Anhui Rinengzhongtian Semiconductor Development QJM160-72 160.0 W 141.5 W 42.42 V 35.01 V 12.53%
Anhui Rinengzhongtian Semiconductor Development QJM165-72 165.0 W 146.0 W 42.5 V 35.4 V 12.92%
Anhui Rinengzhongtian Semiconductor Development QJM170-72 170.0 W 150.5 W 42.7 V 35.6 V 13.32%

How Many Anhui Rinengzhongtian Semiconductor Development QJM165-72 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Anhui Rinengzhongtian Semiconductor Development QJM165-72 (42.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=42.5V and beta_Voc=-0.367%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.52 V 12 panels 594.2 V 20 panels
-10 C (14 F) 47.96 V 12 panels 575.5 V 20 panels
0 C (32 F) 46.4 V 12 panels 556.8 V 21 panels
25 C (77 F STC) 42.5 V 14 panels 595.0 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Anhui Rinengzhongtian Semiconductor Development QJM165-72?

Four comparable CEC modules such as PEIMAR SG165M (165.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
PEIMAR SG165M
PEIMAR
165.0 W Tie (0 W) 42.5 V 12.92% 88.5%
Juli New Energy JLS165M
Juli New Energy
165.0 W Tie (0 W) 42.0 V 12.92% 85.8%
Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B
Hanwha Qcells (Qidong) Co Ltd
165.0 W Tie (0 W) 44.0 V 12.92% 90.1%
JA Solar JAM5-72-165
JA Solar
165.0 W Tie (0 W) 44.79 V 12.92% 89.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Anhui Rinengzhongtian Semiconductor Development QJM165-72?

Evaluate Anhui Rinengzhongtian Semiconductor Development QJM165-72 (165.0 W STC, 42.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Anhui Rinengzhongtian Semiconductor Development QJM165-72 reaches 49.52 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 49 panels for an 8 kW build require 674 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft).
  • 2026 tax credit baseline: cash residential installs of Anhui Rinengzhongtian Semiconductor Development QJM165-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Anhui Rinengzhongtian Semiconductor Development QJM165-72 8 kW Residential Fit

Needs 49 modules (674 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare PEIMAR SG165M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 146.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Anhui Rinengzhongtian Semiconductor Development QJM165-72 by Anhui Rinengzhongtian Semiconductor Development grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Anhui Rinengzhongtian Semiconductor Development QJM165-72 PTC wattage (146.0 W) lower than STC (165.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 146.0 W PTC (88.5% retention) across Anhui Rinengzhongtian Semiconductor Development QJM165-72's 1.277 m2 aperture.

Who should skip Anhui Rinengzhongtian Semiconductor Development QJM165-72 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 49 Anhui Rinengzhongtian Semiconductor Development QJM165-72 panels (674 sq ft) leave unusable roof gaps vs. PEIMAR SG165M.

What is the 1,000 V commercial string limit for Anhui Rinengzhongtian Semiconductor Development QJM165-72?

On 1,000 V commercial inverters at -10 C (47.96 V cold Voc), Anhui Rinengzhongtian Semiconductor Development QJM165-72 fits up to 20 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.