Juli New Energy JLS165M is a 165.0 W STC (141.5 W PTC) Mono-c-Si solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 12.92% efficiency, 42.0 V Voc at 25 C, and 48.56 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 165.0 W
- PTC Wattage
- 141.5 W
- Voc @ 25C
- 42.0 V
- Efficiency
- 12.92%
How Does Juli New Energy JLS165M Compare Against Peer CEC Listings?
How Juli New Energy Juli New Energy JLS165M handles rooftop heat (141.5 W PTC), 8 kW sizing, and cold winter string voltage.
Juli New Energy builds the Juli New Energy JLS165M (Mono-c-Si) as a compact residential or specialty off-grid module delivering 129.2 W/m2 (6.99 percentage points below 19.91% CEC median). Compared against Anhui Rinengzhongtian Semiconductor Development QJM165-72 (165.0 W), this model holds typical 85.8% PTC-to-STC thermal output (141.5 W real-world rating). Mid-range 42.0 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.24 A overcurrent floor served by a 15 A breaker.
Where Does Juli New Energy JLS165M Fall Across Listed CEC Models?
Where Juli New Energy JLS165M (165.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Juli New Energy JLS165M?
Percentile placement of Juli New Energy JLS165M across power density (129.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Juli New Energy JLS165M?
Four critical engineering numbers homeowners and solar installers check first when reviewing Juli New Energy JLS165M specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
165.0 W STC · Higher Than 1.4%
165.0 W STC (-220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
12.92% Aperture Efficiency
Power density 129.2 W/m2 (6.99 percentage points below 19.91% CEC median). PTC/STC ratio: 85.8% (rank #21,654).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.56 V at -10 C (582.7 V string) and 50.43 V at -20 C (11 max).
49 Panels = 8,085 W STC
Occupies 62.6 m2 (674 sq ft) producing 6,934 W PTC; NEC 690.8 OCPD floor is 8.24 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.0 * (1 + (-0.446/100) * (-10 - 25)) = 48.56 V | OCPD = 1.56 * 5.28 = 8.24 A
Inputs from CEC Modules.csv for Juli New Energy JLS165M: Voc=42.0 V, beta_Voc=-0.446%/C, Isc=5.28 A, STC=165.0 W, Area=1.277 m2.
Result: 12 panels max on 600 V (582.7 V); 49 panels for 8 kW (674 sq ft).
What Are the Published CEC Specifications for Juli New Energy JLS165M?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Juli New Energy JLS165M.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 165.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 141.5 W (85.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.0 V / 4.71 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.446 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 12.92% (1.277 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Juli New Energy JLS165M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Juli New Energy JLS165M (165.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 37 | 6.11 kW | 509 sq ft | $1,529 | $2,586 |
| 8 kW Class | 49 | 8.09 kW | 674 sq ft | $2,025 | $3,424 |
| 10 kW Class | 61 | 10.06 kW | 838 sq ft | $2,518 | $4,258 |
Which Sibling Wattage & Trim Variants Belong to This Juli New Energy Series?
All closely matched Juli New Energy wattages and cosmetic trims sharing the Juli New Energy JLS165M architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Juli New Energy JLS155M | 155.0 W | 132.6 W | 42.0 V | 35.0 V | 12.14% |
| Juli New Energy JLS160M | 160.0 W | 137.0 W | 42.0 V | 35.0 V | 12.53% |
| Juli New Energy JLS165M | 165.0 W | 141.5 W | 42.0 V | 35.0 V | 12.92% |
| Juli New Energy JLS170M | 170.0 W | 148.6 W | 42.6 V | 35.5 V | 13.32% |
How Many Juli New Energy JLS165M Modules Fit in a Cold-Weather String?
Maximum series module counts for Juli New Energy JLS165M from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.43 V | 11 panels | 554.7 V | 19 panels |
| -10 C (14 F) | 48.56 V | 12 panels | 582.7 V | 20 panels |
| 0 C (32 F) | 46.68 V | 12 panels | 560.2 V | 21 panels |
| 25 C (77 F STC) | 42.0 V | 14 panels | 588.0 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Juli New Energy JLS165M?
Alternative CEC solar modules from competing brands near Juli New Energy JLS165M (165.0 W), including Anhui Rinengzhongtian Semiconductor Development QJM165-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJM165-72 Anhui Rinengzhongtian Semiconductor Development |
165.0 W | Tie (0 W) | 42.5 V | 12.92% | 88.5% |
| PEIMAR SG165M PEIMAR |
165.0 W | Tie (0 W) | 42.5 V | 12.92% | 88.5% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B Hanwha Qcells (Qidong) Co Ltd |
165.0 W | Tie (0 W) | 44.0 V | 12.92% | 90.1% |
| JA Solar JAM5-72-165 JA Solar |
165.0 W | Tie (0 W) | 44.79 V | 12.92% | 89.7% |
What Are the Design Limits and Best-Fit Uses for Juli New Energy JLS165M?
Evaluate Juli New Energy JLS165M (165.0 W STC, 42.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Juli New Energy JLS165M reaches 50.43 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 49 panels for an 8 kW build require 674 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft).
- 2026 tax credit baseline: cash residential installs of Juli New Energy JLS165M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Juli New Energy JLS165M 8 kW Residential Fit
Needs 49 modules (674 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM165-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 141.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Juli New Energy JLS165M by Juli New Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Juli New Energy JLS165M?
Multiplying Juli New Energy JLS165M's 5.28 A short-circuit current by 1.56 equals 8.24 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Juli New Energy JLS165M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 48.56 V cold Voc at 14 F and handles 5.28 A Isc; string inverters cap Juli New Energy JLS165M at 12 panels on 600 V.
Is Juli New Energy JLS165M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Juli New Energy JLS165M rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)