JA Solar JAM5-72-165 — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM5-72-165 is a 165.0 W STC (148.0 W PTC) Mono-c-Si solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 12.92% efficiency, 44.79 V Voc at 25 C, and 49.81 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
165.0 W
PTC Wattage
148.0 W
Voc @ 25C
44.79 V
Efficiency
12.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM5-72-165 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM5-72-165 (Mono-c-Si) residential solar systems.

Homeowners evaluating JA Solar JAM5-72-165 need 37 panels for 6 kW or 49 panels (674 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft). Under NEC 690.7(A), beta_Voc (-0.32%/C) pushes open-circuit voltage to 49.81 V at 14 F and 51.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does JA Solar JAM5-72-165 Fall Across Listed CEC Models?

Comparison of JA Solar JAM5-72-165 (165.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM5-72-165 (165.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM5-72-1: 165.0 W

What Dataset Percentiles Define JA Solar JAM5-72-165?

Relative ranking of JA Solar JAM5-72-165 across nameplate watts, 89.7% PTC thermal ratio, and module aperture efficiency. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

JA Solar JAM5-72-165 Engineering BenchmarksPercentile comparison of JA Solar JAM5-72-165 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage165.0 WPTC/STC Retention89.7%Module Efficiency12.92%

What Do the Dataset Ranks Show for JA Solar JAM5-72-165?

Summary of JA Solar JAM5-72-165 output rank, 8 kW array size (49 panels), efficiency rating, and 600 V string limit.

Rank #21,351 / 21,677

165.0 W STC · Higher Than 1.4%

165.0 W STC (-220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,422

12.92% Aperture Efficiency

Power density 129.2 W/m2 (6.99 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.81 V at -10 C (597.7 V string) and 51.24 V at -20 C (11 max).

8 kW Reference Array

49 Panels = 8,085 W STC

Occupies 62.6 m2 (674 sq ft) producing 7,252 W PTC; NEC 690.8 OCPD floor is 7.85 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.79 * (1 + (-0.32/100) * (-10 - 25)) = 49.81 V | OCPD = 1.56 * 5.03 = 7.85 A

Inputs from CEC Modules.csv for JA Solar JAM5-72-165: Voc=44.79 V, beta_Voc=-0.32%/C, Isc=5.03 A, STC=165.0 W, Area=1.277 m2.

Result: 12 panels max on 600 V (597.7 V); 49 panels for 8 kW (674 sq ft).

What Are the Published CEC Specifications for JA Solar JAM5-72-165?

Complete CEC test sheet for JA Solar JAM5-72-165 including Isc (5.03 A), Voc (44.79 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM5-72-165.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 165.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 148.0 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.79 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.03 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.2 V / 4.56 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.92% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM5-72-165 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM5-72-165.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 37 6.11 kW 509 sq ft $1,529 $2,586
8 kW Class 49 8.09 kW 674 sq ft $2,025 $3,424
10 kW Class 61 10.06 kW 838 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM5-72-165 series guide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the JA Solar JAM5-72-165 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM5-72-165 165.0 W 148.0 W 44.79 V 36.2 V 12.92%
JA Solar JAM5-72-170 170.0 W 152.6 W 44.96 V 36.4 V 13.32%

How Many JA Solar JAM5-72-165 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAM5-72-165 (44.79 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.79V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.24 V 11 panels 563.6 V 19 panels
-10 C (14 F) 49.81 V 12 panels 597.7 V 20 panels
0 C (32 F) 48.37 V 12 panels 580.4 V 20 panels
25 C (77 F STC) 44.79 V 13 panels 582.3 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM5-72-165?

Four comparable CEC modules such as Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B (165.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B
Hanwha Qcells (Qidong) Co Ltd
165.0 W Tie (0 W) 44.0 V 12.92% 90.1%
Enp Sonne Solar Technikk ENP-M170MO
Enp Sonne Solar Technikk
170.0 W +5.0 W 44.2 V 13.29% 89.3%
Hanwha Qcells (Qidong) Co Ltd SF160-24-P170
Hanwha Qcells (Qidong) Co Ltd
170.0 W +5.0 W 44.1 V 13.32% 88.2%
Jiangyin Hareon Power HR-170W/24V
Jiangyin Hareon Power
170.0 W +5.0 W 43.8 V 13.32% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM5-72-165?

Evaluate JA Solar JAM5-72-165 (165.0 W STC, 44.79 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM5-72-165 reaches 51.24 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 49 panels for an 8 kW build require 674 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM5-72-165 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM5-72-165 8 kW Residential Fit

Needs 49 modules (674 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 148.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM5-72-165 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is JA Solar JAM5-72-165 PTC wattage (148.0 W) lower than STC (165.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 148.0 W PTC (89.7% retention) across JA Solar JAM5-72-165's 1.277 m2 aperture.

Who should skip JA Solar JAM5-72-165 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 49 JA Solar JAM5-72-165 panels (674 sq ft) leave unusable roof gaps vs. Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B.

What is the 1,000 V commercial string limit for JA Solar JAM5-72-165?

On 1,000 V commercial inverters at -10 C (49.81 V cold Voc), JA Solar JAM5-72-165 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM5-72-165.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.