Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM66D45-610/LB is a 610.0 W STC (573.0 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 23.11% efficiency, 48.1 V Voc at 25 C, and 52.26 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
610.0 W
PTC Wattage
573.0 W
Voc @ 25C
48.1 V
Efficiency
23.11%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM66D45-610/LB Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM66D45-610/LB (Mono-c-Si) residential solar systems.

JA Solar JAM66D45-610/LB delivers 231.1 W/m2 (3.20 percentage points above 19.91% CEC median) and strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 53.45 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with CSI Solar Co Ltd CS62-66TB-610H (610.0 W).

Where Does JA Solar JAM66D45-610/LB Fall Across Listed CEC Models?

Comparison of JA Solar JAM66D45-610/LB (610.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM66D45-610/LB (610.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM66D45-: 610.0 W

What Dataset Percentiles Define JA Solar JAM66D45-610/LB?

Relative ranking of JA Solar JAM66D45-610/LB across nameplate watts, 93.9% PTC thermal ratio, and module aperture efficiency.

JA Solar JAM66D45-610/LB Engineering BenchmarksPercentile comparison of JA Solar JAM66D45-610/LB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage610.0 WPTC/STC Retention93.9%Module Efficiency23.11%

What Do the Dataset Ranks Show for JA Solar JAM66D45-610/LB?

Summary of JA Solar JAM66D45-610/LB output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,104 / 21,677

Top 5.6% STC Output

610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #970

23.11% Aperture Efficiency

Power density 231.1 W/m2 (3.20 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.26 V at -10 C (574.9 V string) and 53.45 V at -20 C (11 max).

8 kW Reference Array

14 Panels = 8,540 W STC

Occupies 37.0 m2 (398 sq ft) producing 8,022 W PTC; NEC 690.8 OCPD floor is 25.04 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.1 * (1 + (-0.247/100) * (-10 - 25)) = 52.26 V | OCPD = 1.56 * 16.05 = 25.04 A

Inputs from CEC Modules.csv for JA Solar JAM66D45-610/LB: Voc=48.1 V, beta_Voc=-0.247%/C, Isc=16.05 A, STC=610.0 W, Area=2.64 m2.

Result: 11 panels max on 600 V (574.9 V); 14 panels for 8 kW (398 sq ft).

What Are the Published CEC Specifications for JA Solar JAM66D45-610/LB?

Complete CEC test sheet for JA Solar JAM66D45-610/LB including Isc (16.05 A), Voc (48.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM66D45-610/LB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 610.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 573.0 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 16.05 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.77 V / 15.34 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.247 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.11% (2.64 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many JA Solar JAM66D45-610/LB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM66D45-610/LB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.1 kW 284 sq ft $1,527 $2,582
8 kW Class 14 8.54 kW 398 sq ft $2,137 $3,614
10 kW Class 17 10.37 kW 483 sq ft $2,596 $4,389

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM66D45-610/LB series guide.

Sibling CEC listings grouped into the JA Solar JAM66D45-610/LB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM66D45-600/LB 600.0 W 563.4 W 47.7 V 39.44 V 22.73%
JA Solar JAM66D45-605/LB 605.0 W 568.2 W 47.9 V 39.6 V 22.92%
JA Solar JAM66D45-610/LB 610.0 W 573.0 W 48.1 V 39.77 V 23.11%
JA Solar JAM66D45-615/LB 615.0 W 577.9 W 48.3 V 39.96 V 23.3%
JA Solar JAM66D45-620/LB 620.0 W 582.7 W 48.5 V 40.21 V 23.48%

How Many JA Solar JAM66D45-610/LB Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAM66D45-610/LB (48.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.1V and beta_Voc=-0.247%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.45 V 11 panels 588.0 V 18 panels
-10 C (14 F) 52.26 V 11 panels 574.9 V 19 panels
0 C (32 F) 51.07 V 11 panels 561.8 V 19 panels
25 C (77 F STC) 48.1 V 12 panels 577.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM66D45-610/LB?

Four comparable CEC modules such as CSI Solar Co Ltd CS62-66TB-610H (610.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS62-66TB-610H
CSI Solar Co Ltd
610.0 W Tie (0 W) 48.0 V 23.28% 95.1%
CSI Solar Co Ltd CS62-66TB-610HP
CSI Solar Co Ltd
610.0 W Tie (0 W) 48.0 V 23.28% 95.1%
Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF
Boviet Solar Technology Co Ltd
610.0 W Tie (0 W) 48.25 V 24.21% 95.3%
Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF-DG
Boviet Solar Technology Co Ltd
610.0 W Tie (0 W) 48.25 V 24.21% 95.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM66D45-610/LB?

Evaluate JA Solar JAM66D45-610/LB (610.0 W STC, 48.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM66D45-610/LB reaches 53.45 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 398 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM66D45-610/LB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM66D45-610/LB 8 kW Residential Fit

Needs 14 modules (398 sq ft) with a 30 A string OCPD, offsetting ~$2,137/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS62-66TB-610H.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 573.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM66D45-610/LB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM66D45-610/LB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM66D45-610/LB cold Voc rises from 48.1 V to 52.26 V (beta_Voc -0.247%/C), capping a 600 V string at 11 panels (574.9 V).

How much roof area does an 8 kW array of JA Solar JAM66D45-610/LB need?

An 8 kW DC system uses 14 JA Solar JAM66D45-610/LB modules (8,540 W STC / 8,022 W PTC), covering roughly 398 sq ft and saving ~$2,137/yr at 18.54 c/kWh.

How does JA Solar JAM66D45-610/LB compare against CSI Solar Co Ltd CS62-66TB-610H?

JA Solar JAM66D45-610/LB outputs 610.0 W STC (48.1 V Voc, rank #1,104 of 21,677), while CSI Solar Co Ltd CS62-66TB-610H delivers 610.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.