JA Solar JAM66D45-610/LB is a 610.0 W STC (573.0 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 23.11% efficiency, 48.1 V Voc at 25 C, and 52.26 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 610.0 W
- PTC Wattage
- 573.0 W
- Voc @ 25C
- 48.1 V
- Efficiency
- 23.11%
How Does JA Solar JAM66D45-610/LB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM66D45-610/LB (Mono-c-Si) residential solar systems.
JA Solar JAM66D45-610/LB delivers 231.1 W/m2 (3.20 percentage points above 19.91% CEC median) and strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 53.45 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with CSI Solar Co Ltd CS62-66TB-610H (610.0 W).
Where Does JA Solar JAM66D45-610/LB Fall Across Listed CEC Models?
Comparison of JA Solar JAM66D45-610/LB (610.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAM66D45-610/LB?
Relative ranking of JA Solar JAM66D45-610/LB across nameplate watts, 93.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAM66D45-610/LB?
Summary of JA Solar JAM66D45-610/LB output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.
Top 5.6% STC Output
610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.11% Aperture Efficiency
Power density 231.1 W/m2 (3.20 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.26 V at -10 C (574.9 V string) and 53.45 V at -20 C (11 max).
14 Panels = 8,540 W STC
Occupies 37.0 m2 (398 sq ft) producing 8,022 W PTC; NEC 690.8 OCPD floor is 25.04 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.1 * (1 + (-0.247/100) * (-10 - 25)) = 52.26 V | OCPD = 1.56 * 16.05 = 25.04 A
Inputs from CEC Modules.csv for JA Solar JAM66D45-610/LB: Voc=48.1 V, beta_Voc=-0.247%/C, Isc=16.05 A, STC=610.0 W, Area=2.64 m2.
Result: 11 panels max on 600 V (574.9 V); 14 panels for 8 kW (398 sq ft).
What Are the Published CEC Specifications for JA Solar JAM66D45-610/LB?
Complete CEC test sheet for JA Solar JAM66D45-610/LB including Isc (16.05 A), Voc (48.1 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 610.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 573.0 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 16.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.77 V / 15.34 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.11% (2.64 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many JA Solar JAM66D45-610/LB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM66D45-610/LB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.1 kW | 284 sq ft | $1,527 | $2,582 |
| 8 kW Class | 14 | 8.54 kW | 398 sq ft | $2,137 | $3,614 |
| 10 kW Class | 17 | 10.37 kW | 483 sq ft | $2,596 | $4,389 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM66D45-610/LB series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM66D45-600/LB | 600.0 W | 563.4 W | 47.7 V | 39.44 V | 22.73% |
| JA Solar JAM66D45-605/LB | 605.0 W | 568.2 W | 47.9 V | 39.6 V | 22.92% |
| JA Solar JAM66D45-610/LB | 610.0 W | 573.0 W | 48.1 V | 39.77 V | 23.11% |
| JA Solar JAM66D45-615/LB | 615.0 W | 577.9 W | 48.3 V | 39.96 V | 23.3% |
| JA Solar JAM66D45-620/LB | 620.0 W | 582.7 W | 48.5 V | 40.21 V | 23.48% |
How Many JA Solar JAM66D45-610/LB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAM66D45-610/LB (48.1 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.45 V | 11 panels | 588.0 V | 18 panels |
| -10 C (14 F) | 52.26 V | 11 panels | 574.9 V | 19 panels |
| 0 C (32 F) | 51.07 V | 11 panels | 561.8 V | 19 panels |
| 25 C (77 F STC) | 48.1 V | 12 panels | 577.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM66D45-610/LB?
Four comparable CEC modules such as CSI Solar Co Ltd CS62-66TB-610H (610.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS62-66TB-610H CSI Solar Co Ltd |
610.0 W | Tie (0 W) | 48.0 V | 23.28% | 95.1% |
| CSI Solar Co Ltd CS62-66TB-610HP CSI Solar Co Ltd |
610.0 W | Tie (0 W) | 48.0 V | 23.28% | 95.1% |
| Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF Boviet Solar Technology Co Ltd |
610.0 W | Tie (0 W) | 48.25 V | 24.21% | 95.3% |
| Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF-DG Boviet Solar Technology Co Ltd |
610.0 W | Tie (0 W) | 48.25 V | 24.21% | 95.3% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM66D45-610/LB?
Evaluate JA Solar JAM66D45-610/LB (610.0 W STC, 48.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM66D45-610/LB reaches 53.45 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 398 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM66D45-610/LB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM66D45-610/LB 8 kW Residential Fit
Needs 14 modules (398 sq ft) with a 30 A string OCPD, offsetting ~$2,137/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS62-66TB-610H.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 573.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM66D45-610/LB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM66D45-610/LB panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM66D45-610/LB cold Voc rises from 48.1 V to 52.26 V (beta_Voc -0.247%/C), capping a 600 V string at 11 panels (574.9 V).
How much roof area does an 8 kW array of JA Solar JAM66D45-610/LB need?
An 8 kW DC system uses 14 JA Solar JAM66D45-610/LB modules (8,540 W STC / 8,022 W PTC), covering roughly 398 sq ft and saving ~$2,137/yr at 18.54 c/kWh.
How does JA Solar JAM66D45-610/LB compare against CSI Solar Co Ltd CS62-66TB-610H?
JA Solar JAM66D45-610/LB outputs 610.0 W STC (48.1 V Voc, rank #1,104 of 21,677), while CSI Solar Co Ltd CS62-66TB-610H delivers 610.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)