JA Solar JAM66D45-595/LB is a 595.0 W STC (558.6 W PTC) Mono-c-Si solar module ranking #1,462 of 21,677 CEC listings (top 7.4%; higher than 92.6% of peers). It delivers 22.54% efficiency, 47.5 V Voc at 25 C, and 51.61 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 595.0 W
- PTC Wattage
- 558.6 W
- Voc @ 25C
- 47.5 V
- Efficiency
- 22.54%
How Does JA Solar JAM66D45-595/LB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM66D45-595/LB (Mono-c-Si) residential solar systems.
Homeowners evaluating JA Solar JAM66D45-595/LB need 11 panels for 6 kW or 14 panels (398 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.247%/C) pushes open-circuit voltage to 51.61 V at 14 F and 52.78 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does JA Solar JAM66D45-595/LB Fall Across Listed CEC Models?
Comparison of JA Solar JAM66D45-595/LB (595.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAM66D45-595/LB?
Relative ranking of JA Solar JAM66D45-595/LB across nameplate watts, 93.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAM66D45-595/LB?
Summary of JA Solar JAM66D45-595/LB output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.
Top 7.4% STC Output
595.0 W STC (+210.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.54% Aperture Efficiency
Power density 225.4 W/m2 (2.63 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.61 V at -10 C (567.7 V string) and 52.78 V at -20 C (11 max).
14 Panels = 8,330 W STC
Occupies 37.0 m2 (398 sq ft) producing 7,820 W PTC; NEC 690.8 OCPD floor is 24.8 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.5 * (1 + (-0.247/100) * (-10 - 25)) = 51.61 V | OCPD = 1.56 * 15.9 = 24.8 A
Inputs from CEC Modules.csv for JA Solar JAM66D45-595/LB: Voc=47.5 V, beta_Voc=-0.247%/C, Isc=15.9 A, STC=595.0 W, Area=2.64 m2.
Result: 11 panels max on 600 V (567.7 V); 14 panels for 8 kW (398 sq ft).
What Are the Published CEC Specifications for JA Solar JAM66D45-595/LB?
Complete CEC test sheet for JA Solar JAM66D45-595/LB including Isc (15.9 A), Voc (47.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 595.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 558.6 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.27 V / 15.15 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.54% (2.64 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many JA Solar JAM66D45-595/LB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM66D45-595/LB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.54 kW | 313 sq ft | $1,637 | $2,768 |
| 8 kW Class | 14 | 8.33 kW | 398 sq ft | $2,085 | $3,525 |
| 10 kW Class | 17 | 10.12 kW | 483 sq ft | $2,533 | $4,283 |
How Many JA Solar JAM66D45-595/LB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAM66D45-595/LB (47.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.78 V | 11 panels | 580.6 V | 18 panels |
| -10 C (14 F) | 51.61 V | 11 panels | 567.7 V | 19 panels |
| 0 C (32 F) | 50.43 V | 11 panels | 554.7 V | 19 panels |
| 25 C (77 F STC) | 47.5 V | 12 panels | 570.0 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM66D45-595/LB?
Four comparable CEC modules such as CSI Solar Co Ltd CS62-66TB-595HP (595.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS62-66TB-595HP CSI Solar Co Ltd |
595.0 W | Tie (0 W) | 47.4 V | 22.71% | 95.0% |
| Boviet Solar Technology Co Ltd BVM8611M-595R-H-HC-BF Boviet Solar Technology Co Ltd |
595.0 W | Tie (0 W) | 47.65 V | 23.61% | 95.3% |
| Boviet Solar Technology Co Ltd BVM8611M-595R-H-HC-BF-DG Boviet Solar Technology Co Ltd |
595.0 W | Tie (0 W) | 47.65 V | 23.61% | 95.3% |
| CSI Solar Co Ltd CS62-66TB-590H CSI Solar Co Ltd |
590.0 W | -5.0 W | 47.2 V | 22.52% | 95.0% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM66D45-595/LB?
Evaluate JA Solar JAM66D45-595/LB (595.0 W STC, 47.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM66D45-595/LB reaches 52.78 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 398 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM66D45-595/LB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM66D45-595/LB 8 kW Residential Fit
Needs 14 modules (398 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS62-66TB-595HP.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 558.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM66D45-595/LB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAM66D45-595/LB PTC wattage (558.6 W) lower than STC (595.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 558.6 W PTC (93.9% retention) across JA Solar JAM66D45-595/LB's 2.64 m2 aperture.
Who should skip JA Solar JAM66D45-595/LB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 JA Solar JAM66D45-595/LB panels (398 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS62-66TB-595HP.
What is the 1,000 V commercial string limit for JA Solar JAM66D45-595/LB?
On 1,000 V commercial inverters at -10 C (51.61 V cold Voc), JA Solar JAM66D45-595/LB fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM66D45-595/LB.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)