JA Solar JAM72D40-600/MB is a 600.0 W STC (562.4 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.81% efficiency, 52.79 V Voc at 25 C, and 57.35 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 600.0 W
- PTC Wattage
- 562.4 W
- Voc @ 25C
- 52.79 V
- Efficiency
- 23.81%
How Does JA Solar JAM72D40-600/MB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM72D40-600/MB (Mono-c-Si) residential solar systems.
JA Solar JAM72D40-600/MB delivers 238.1 W/m2 (3.90 percentage points above 19.91% CEC median) and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 58.66 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600 (600.0 W).
Where Does JA Solar JAM72D40-600/MB Fall Across Listed CEC Models?
Comparison of JA Solar JAM72D40-600/MB (600.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAM72D40-600/MB?
Relative ranking of JA Solar JAM72D40-600/MB across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAM72D40-600/MB?
Summary of JA Solar JAM72D40-600/MB output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.
Top 6.7% STC Output
600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.81% Aperture Efficiency
Power density 238.1 W/m2 (3.90 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.35 V at -10 C (573.5 V string) and 58.66 V at -20 C (10 max).
14 Panels = 8,400 W STC
Occupies 35.3 m2 (380 sq ft) producing 7,874 W PTC; NEC 690.8 OCPD floor is 21.9 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.79 * (1 + (-0.247/100) * (-10 - 25)) = 57.35 V | OCPD = 1.56 * 14.04 = 21.9 A
Inputs from CEC Modules.csv for JA Solar JAM72D40-600/MB: Voc=52.79 V, beta_Voc=-0.247%/C, Isc=14.04 A, STC=600.0 W, Area=2.52 m2.
Result: 10 panels max on 600 V (573.5 V); 14 panels for 8 kW (380 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72D40-600/MB?
Complete CEC test sheet for JA Solar JAM72D40-600/MB including Isc (14.04 A), Voc (52.79 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 562.4 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.79 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.95 V / 13.38 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.81% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many JA Solar JAM72D40-600/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM72D40-600/MB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.0 kW | 271 sq ft | $1,502 | $2,539 |
| 8 kW Class | 14 | 8.4 kW | 380 sq ft | $2,102 | $3,555 |
| 10 kW Class | 17 | 10.2 kW | 461 sq ft | $2,553 | $4,317 |
How Many JA Solar JAM72D40-600/MB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAM72D40-600/MB (52.79 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.66 V | 10 panels | 586.6 V | 17 panels |
| -10 C (14 F) | 57.35 V | 10 panels | 573.5 V | 17 panels |
| 0 C (32 F) | 56.05 V | 10 panels | 560.5 V | 17 panels |
| 25 C (77 F STC) | 52.79 V | 11 panels | 580.7 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D40-600/MB?
Four comparable CEC modules such as JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600 (600.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600 JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD |
600.0 W | Tie (0 W) | 52.8 V | 23.26% | 94.7% |
| CSI Solar Co Ltd CS6W-600TB-AG CSI Solar Co Ltd |
600.0 W | Tie (0 W) | 53.0 V | 23.9% | 95.0% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT600-144TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
600.0 W | Tie (0 W) | 53.05 V | 23.26% | 95.5% |
| AMPS Solar AMPS-600N-144SW AMPS Solar |
600.0 W | Tie (0 W) | 53.3 V | 23.44% | 95.0% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D40-600/MB?
Evaluate JA Solar JAM72D40-600/MB (600.0 W STC, 52.79 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D40-600/MB reaches 58.66 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 380 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72D40-600/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72D40-600/MB 8 kW Residential Fit
Needs 14 modules (380 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 562.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72D40-600/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM72D40-600/MB panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM72D40-600/MB cold Voc rises from 52.79 V to 57.35 V (beta_Voc -0.247%/C), capping a 600 V string at 10 panels (573.5 V).
How much roof area does an 8 kW array of JA Solar JAM72D40-600/MB need?
An 8 kW DC system uses 14 JA Solar JAM72D40-600/MB modules (8,400 W STC / 7,874 W PTC), covering roughly 380 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does JA Solar JAM72D40-600/MB compare against JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600?
JA Solar JAM72D40-600/MB outputs 600.0 W STC (52.79 V Voc, rank #1,320 of 21,677), while JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600 delivers 600.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)