Skip to main content
WireAndSun
Calculators
CEC PV Module

Enp Sonne Solar Technikk ENP-M170MO — CEC Solar Module Specifications

Manufacturer: Enp Sonne Solar Technikk Registry: CEC Verified Engineering Specification

Enp Sonne Solar Technikk ENP-M170MO is a 170.0 W STC (151.8 W PTC) Mono-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 13.29% efficiency, 44.2 V Voc at 25 C, and 50.06 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
170.0 W
PTC Wattage
151.8 W
Voc @ 25C
44.2 V
Efficiency
13.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Enp Sonne Solar Technikk ENP-M170MO Compare Against Peer CEC Listings?

How Enp Sonne Solar Technikk Enp Sonne Solar Technikk ENP-M170MO handles rooftop heat (151.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Enp Sonne Solar Technikk ENP-M170MO exhibits 5.15 A short-circuit current, requiring a 8.03 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,323 of 21,677 (240.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 61.4 m2 for an 8 kW system (59 panels for 10 kW). Mid-range 44.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Enp Sonne Solar Technikk ENP-M170MO Fall Across Listed CEC Models?

Where Enp Sonne Solar Technikk ENP-M170MO (170.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Enp Sonne Solar Technikk ENP-M170MO (170.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCEnp Sonne Solar Te: 170.0 W

What Dataset Percentiles Define Enp Sonne Solar Technikk ENP-M170MO?

Percentile placement of Enp Sonne Solar Technikk ENP-M170MO across power density (132.9 W/m2), thermal retention, and nameplate STC wattage.

Enp Sonne Solar Technikk ENP-M170MO Engineering BenchmarksPercentile comparison of Enp Sonne Solar Technikk ENP-M170MO wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage170.0 WPTC/STC Retention89.3%Module Efficiency13.29%

What Do the Dataset Ranks Show for Enp Sonne Solar Technikk ENP-M170MO?

Four critical engineering numbers homeowners and solar installers check first when reviewing Enp Sonne Solar Technikk ENP-M170MO specifications.

Rank #21,323 / 21,677

170.0 W STC · Higher Than 1.5%

170.0 W STC (-215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,324

13.29% Aperture Efficiency

Power density 132.9 W/m2 (6.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.06 V at -10 C (550.7 V string) and 51.74 V at -20 C (11 max).

8 kW Reference Array

48 Panels = 8,160 W STC

Occupies 61.4 m2 (661 sq ft) producing 7,286 W PTC; NEC 690.8 OCPD floor is 8.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.2 * (1 + (-0.379/100) * (-10 - 25)) = 50.06 V | OCPD = 1.56 * 5.15 = 8.03 A

Inputs from CEC Modules.csv for Enp Sonne Solar Technikk ENP-M170MO: Voc=44.2 V, beta_Voc=-0.379%/C, Isc=5.15 A, STC=170.0 W, Area=1.279 m2.

Result: 11 panels max on 600 V (550.7 V); 48 panels for 8 kW (661 sq ft).

What Are the Published CEC Specifications for Enp Sonne Solar Technikk ENP-M170MO?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Enp Sonne Solar Technikk ENP-M170MO.

Official California Energy Commission (NREL SAM) test parameters for Enp Sonne Solar Technikk ENP-M170MO.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 170.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 151.8 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.15 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.0 V / 4.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.379 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.29% (1.279 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Enp Sonne Solar Technikk ENP-M170MO Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Enp Sonne Solar Technikk ENP-M170MO (170.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 36 6.12 kW 496 sq ft $1,532 $2,590
8 kW Class 48 8.16 kW 661 sq ft $2,042 $3,454
10 kW Class 59 10.03 kW 812 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This Enp Sonne Solar Technikk Series?

All closely matched Enp Sonne Solar Technikk wattages and cosmetic trims sharing the Enp Sonne Solar Technikk ENP-M170MO architecture.

Sibling CEC listings grouped into the Enp Sonne Solar Technikk ENP-M170MO wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Enp Sonne Solar Technikk ENP-M165MO 165.0 W 147.3 W 43.6 V 35.4 V 12.9%
Enp Sonne Solar Technikk ENP-M170MO 170.0 W 151.8 W 44.2 V 35.0 V 13.29%

How Many Enp Sonne Solar Technikk ENP-M170MO Modules Fit in a Cold-Weather String?

Maximum series module counts for Enp Sonne Solar Technikk ENP-M170MO from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.2V and beta_Voc=-0.379%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.74 V 11 panels 569.1 V 19 panels
-10 C (14 F) 50.06 V 11 panels 550.7 V 19 panels
0 C (32 F) 48.39 V 12 panels 580.7 V 20 panels
25 C (77 F STC) 44.2 V 13 panels 574.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Enp Sonne Solar Technikk ENP-M170MO?

Alternative CEC solar modules from competing brands near Enp Sonne Solar Technikk ENP-M170MO (170.0 W), including Hanwha Qcells (Qidong) Co Ltd SF160-24-P170.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd SF160-24-P170
Hanwha Qcells (Qidong) Co Ltd
170.0 W Tie (0 W) 44.1 V 13.32% 88.2%
Jiangyin Hareon Power HR-170W/24V
Jiangyin Hareon Power
170.0 W Tie (0 W) 43.8 V 13.32% 89.8%
Suntech Power STP170S-24/Ad+
Suntech Power
170.0 W Tie (0 W) 43.8 V 13.32% 89.1%
Suntech Power STP170S-24/Adb+
Suntech Power
170.0 W Tie (0 W) 43.8 V 13.32% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Enp Sonne Solar Technikk ENP-M170MO?

Evaluate Enp Sonne Solar Technikk ENP-M170MO (170.0 W STC, 44.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Enp Sonne Solar Technikk ENP-M170MO reaches 51.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 48 panels for an 8 kW build require 661 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (661 sq ft).
  • 2026 tax credit baseline: cash residential installs of Enp Sonne Solar Technikk ENP-M170MO carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Enp Sonne Solar Technikk ENP-M170MO 8 kW Residential Fit

Needs 48 modules (661 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF160-24-P170.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 151.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Enp Sonne Solar Technikk ENP-M170MO by Enp Sonne Solar Technikk grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Enp Sonne Solar Technikk ENP-M170MO PTC wattage (151.8 W) lower than STC (170.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 151.8 W PTC (89.3% retention) across Enp Sonne Solar Technikk ENP-M170MO's 1.279 m2 aperture.

Who should skip Enp Sonne Solar Technikk ENP-M170MO on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 48 Enp Sonne Solar Technikk ENP-M170MO panels (661 sq ft) leave unusable roof gaps vs. Hanwha Qcells (Qidong) Co Ltd SF160-24-P170.

What is the 1,000 V commercial string limit for Enp Sonne Solar Technikk ENP-M170MO?

On 1,000 V commercial inverters at -10 C (50.06 V cold Voc), Enp Sonne Solar Technikk ENP-M170MO fits up to 19 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.