PEIMAR SF360M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SF360M is a 360.0 W STC (336.6 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 20.57% efficiency, 41.2 V Voc at 25 C, and 45.04 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
336.6 W
Voc @ 25C
41.2 V
Efficiency
20.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SF360M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SF360M (Mono-c-Si) residential solar systems. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Homeowners evaluating PEIMAR SF360M need 17 panels for 6 kW or 23 panels (433 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (433 sq ft). Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 45.04 V at 14 F and 46.13 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PEIMAR SF360M Fall Across Listed CEC Models?

Comparison of PEIMAR SF360M (360.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SF360M (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SF360M: 360.0 W

What Dataset Percentiles Define PEIMAR SF360M?

Relative ranking of PEIMAR SF360M across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

PEIMAR SF360M Engineering BenchmarksPercentile comparison of PEIMAR SF360M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention93.5%Module Efficiency20.57%

What Do the Dataset Ranks Show for PEIMAR SF360M?

Summary of PEIMAR SF360M output rank, 8 kW array size (23 panels), efficiency rating, and 600 V string limit.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,219

20.57% Aperture Efficiency

Power density 205.7 W/m2 (0.66 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.04 V at -10 C (585.5 V string) and 46.13 V at -20 C (13 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 40.2 m2 (433 sq ft) producing 7,742 W PTC; NEC 690.8 OCPD floor is 17.35 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.2 * (1 + (-0.266/100) * (-10 - 25)) = 45.04 V | OCPD = 1.56 * 11.12 = 17.35 A

Inputs from CEC Modules.csv for PEIMAR SF360M: Voc=41.2 V, beta_Voc=-0.266%/C, Isc=11.12 A, STC=360.0 W, Area=1.75 m2.

Result: 13 panels max on 600 V (585.5 V); 23 panels for 8 kW (433 sq ft).

What Are the Published CEC Specifications for PEIMAR SF360M?

Complete CEC test sheet for PEIMAR SF360M including Isc (11.12 A), Voc (41.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SF360M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 336.6 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.12 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.3 V / 10.5 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.57% (1.75 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SF360M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SF360M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 320 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 433 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 527 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SF360M series guide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the PEIMAR SF360M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SF350M 350.0 W 327.0 W 40.7 V 33.9 V 20.0%
PEIMAR SF355M 355.0 W 331.8 W 40.92 V 34.1 V 20.29%
PEIMAR SF360M 360.0 W 336.6 W 41.2 V 34.3 V 20.57%
PEIMAR SF365M 365.0 W 341.4 W 42.09 V 34.5 V 20.86%

How Many PEIMAR SF360M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PEIMAR SF360M (41.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.2V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.13 V 13 panels 599.7 V 21 panels
-10 C (14 F) 45.04 V 13 panels 585.5 V 22 panels
0 C (32 F) 43.94 V 13 panels 571.2 V 22 panels
25 C (77 F STC) 41.2 V 14 panels 576.8 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SF360M?

Four comparable CEC modules such as DualSun SAS DualSun 360M-120-00 (360.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 360M-120-00
DualSun SAS
360.0 W Tie (0 W) 40.9 V 19.89% 93.3%
DualSun SAS DualSun 360M-120-01
DualSun SAS
360.0 W Tie (0 W) 40.9 V 19.89% 93.2%
CSI Solar Co Ltd CS3L-360P
CSI Solar Co Ltd
360.0 W Tie (0 W) 40.6 V 20.11% 92.4%
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W Tie (0 W) 40.5 V 20.0% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SF360M?

Evaluate PEIMAR SF360M (360.0 W STC, 41.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SF360M reaches 46.13 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 433 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (433 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SF360M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SF360M 8 kW Residential Fit

Needs 23 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 360M-120-00.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 336.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SF360M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Why is PEIMAR SF360M PTC wattage (336.6 W) lower than STC (360.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 336.6 W PTC (93.5% retention) across PEIMAR SF360M's 1.75 m2 aperture.

Who should skip PEIMAR SF360M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 PEIMAR SF360M panels (433 sq ft) leave unusable roof gaps vs. DualSun SAS DualSun 360M-120-00.

What is the 1,000 V commercial string limit for PEIMAR SF360M?

On 1,000 V commercial inverters at -10 C (45.04 V cold Voc), PEIMAR SF360M fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SF360M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.