Manufacturer: DYNAPOWER COMPANY LLC Registry: CEC Verified Engineering Specification

DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} outputs 1,294,180 W AC at 800 V, 3-phase (934.0 A continuous, 1,200 A OCPD), ranking #21 of 2,343 CEC inverters at 98.82% efficiency with a 1,020-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,294,180 W
AC Voltage
800 V, 3-phase
Min PV Breaker
1,200 A (parallel Cu feeders)
CEC Efficiency
98.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 800 V, 3-phase grid-support overview for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}.

Rated at 1,294,180 W AC (934.0 A continuous), DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} ranks #21 of 2,343 CEC units at 98.82% efficiency (+0.52 pts vs the 98.3% 800 V median). Minimum 75 C copper conductor sizing for its 1,200 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 1,500 V DC at record local winter lows.

Where Does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} Fall Across Listed CEC Models?

Marks DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (1,294,180 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (1,294,180 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDYNAPOWER COMPANY : 1,294,180 W

What Dataset Percentiles Define DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?

Benchmarks DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} continuous AC output, 98.82% CEC weighted efficiency, and 1,200 A OCPD breaker demand.

DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} Technical ThresholdsPercentile comparison for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,294,180 WCEC Efficiency98.82%Backfeed Breaker1,200 A

What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?

Four key NEC 705.12 and California Energy Commission metrics defining DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} by DYNAPOWER COMPANY LLC.

Eff #21 / 2,343

98.82% CEC Weighted Efficiency

+0.52 pts vs the 98.3% 800 V median; overall power rank #144 (1,294,180 W, top 6.1%; higher than 93.9% of peers).

NEC 705.12 Check

1,200 A Required Backfeed OCPD

125% x 934.0 A = 1167.5 A -> 1,200 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,020 V - 1,500 V (Max 1,500 V DC)

Tracking span of 480.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1294180.0W / 800 V 3-phase -> 934.0 A | Breaker >= 1.25 * 934.0 = 1167.5 A -> 1,200 A

CEC Inverters.csv for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}: Paco=1294180.0 W, Vac=800 V, Vdcmax=1500.0 V, Eff=98.82%.

Result: Min 1,200 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (800V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}.

Official California Energy Commission (NREL SAM) test parameters for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,294,180 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 800 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,020 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1047.75 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.82% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (800 V, 3-phase)?

Evaluates DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (1,200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (1200 A required OCPD at 800 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (800V) 40 A 1,200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (800V) 80 A 1,200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (800V) 120 A 1,200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (800V) 160 A 1,200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (800V) 240 A 1,200 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?

Sample PV string lengths aligned within 1,020-1,500 V MPPT and 1,500 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 1020.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 24 to 26 panels 15.34 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 31 to 35 panels 15.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 30 to 33 panels 14.03 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 36 panels (fixed) 7.2 kW

Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?

Competing CEC grid-support inverters near 1,294,180 W AC and 800 V, 3-phase, led by NEXTRACKER LLC: NXPCS1670K-HUD {800V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
NEXTRACKER LLC: NXPCS1670K-HUD {800V}
NEXTRACKER LLC
1,673,400 W +379220 W 800.0 V 1500.0 V 98.11%
NEXTRACKER LLC: NXPCS800K-HUD {800V}
NEXTRACKER LLC
801,420 W -492760 W 800.0 V 1500.0 V 97.97%
Sungrow Power Supply Co Ltd: SC2000UD-US {800V}
Sungrow Power Supply Co Ltd
2,014,870 W +720690 W 800.0 V 1500.0 V 97.8%
Delta Electronics: DP350U-US-XX {800V}
Delta Electronics
352,401 W -941779 W 800.0 V 1330.0 V 98.48%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?

Check DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (1,294,180 W AC, 1,200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}.

DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,200 A OCPD breaker (934.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.82%) and MPPT window (1,020-1,500 V) directly against NEXTRACKER LLC: NXPCS1670K-HUD {800V} (1,673,400 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.

What breaker and wire size does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} require?

At 1,294,180 W continuous AC (800 V, 3-phase), continuous current is 934.0 A; 125% NEC 690.8/705.12 sizing requires a 1,200 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} require?

At 1,294,180 W AC and 800 V, 3-phase, continuous line current is 934.0 A, requiring a 1,200 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.

How does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} compare to NEXTRACKER LLC: NXPCS1670K-HUD {800V}?

DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} delivers 1,294,180 W AC at 98.82% CEC efficiency with a 1,500 V DC ceiling, while NEXTRACKER LLC: NXPCS1670K-HUD {800V} outputs 1,673,400 W at 800 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.