DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} outputs 1,294,180 W AC at 800 V, 3-phase (934.0 A continuous, 1,200 A OCPD), ranking #21 of 2,343 CEC inverters at 98.82% efficiency with a 1,020-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,294,180 W
- AC Voltage
- 800 V, 3-phase
- Min PV Breaker
- 1,200 A (parallel Cu feeders)
- CEC Efficiency
- 98.82%
How Does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 800 V, 3-phase grid-support overview for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}.
Rated at 1,294,180 W AC (934.0 A continuous), DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} ranks #21 of 2,343 CEC units at 98.82% efficiency (+0.52 pts vs the 98.3% 800 V median). Minimum 75 C copper conductor sizing for its 1,200 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 1,500 V DC at record local winter lows.
Where Does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} Fall Across Listed CEC Models?
Marks DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (1,294,180 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?
Benchmarks DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} continuous AC output, 98.82% CEC weighted efficiency, and 1,200 A OCPD breaker demand.
What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?
Four key NEC 705.12 and California Energy Commission metrics defining DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} by DYNAPOWER COMPANY LLC.
98.82% CEC Weighted Efficiency
+0.52 pts vs the 98.3% 800 V median; overall power rank #144 (1,294,180 W, top 6.1%; higher than 93.9% of peers).
1,200 A Required Backfeed OCPD
125% x 934.0 A = 1167.5 A -> 1,200 A standard OCPD using parallel Cu feeders (75 C).
1,020 V - 1,500 V (Max 1,500 V DC)
Tracking span of 480.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1294180.0W / 800 V 3-phase -> 934.0 A | Breaker >= 1.25 * 934.0 = 1167.5 A -> 1,200 A
CEC Inverters.csv for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}: Paco=1294180.0 W, Vac=800 V, Vdcmax=1500.0 V, Eff=98.82%.
Result: Min 1,200 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (800V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,294,180 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 800 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 1,020 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1047.75 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.82% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (800 V, 3-phase)?
Evaluates DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (1,200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (800V) | 40 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (800V) | 80 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (800V) | 120 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (800V) | 160 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (800V) | 240 A | 1,200 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?
Sample PV string lengths aligned within 1,020-1,500 V MPPT and 1,500 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 24 to 26 panels | 15.34 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 31 to 35 panels | 15.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 30 to 33 panels | 14.03 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 36 panels (fixed) | 7.2 kW |
Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?
Competing CEC grid-support inverters near 1,294,180 W AC and 800 V, 3-phase, led by NEXTRACKER LLC: NXPCS1670K-HUD {800V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| NEXTRACKER LLC: NXPCS1670K-HUD {800V} NEXTRACKER LLC |
1,673,400 W | +379220 W | 800.0 V | 1500.0 V | 98.11% |
| NEXTRACKER LLC: NXPCS800K-HUD {800V} NEXTRACKER LLC |
801,420 W | -492760 W | 800.0 V | 1500.0 V | 97.97% |
| Sungrow Power Supply Co Ltd: SC2000UD-US {800V} Sungrow Power Supply Co Ltd |
2,014,870 W | +720690 W | 800.0 V | 1500.0 V | 97.8% |
| Delta Electronics: DP350U-US-XX {800V} Delta Electronics |
352,401 W | -941779 W | 800.0 V | 1330.0 V | 98.48% |
What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}?
Check DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} (1,294,180 W AC, 1,200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}.
DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 1,200 A OCPD breaker (934.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.82%) and MPPT window (1,020-1,500 V) directly against NEXTRACKER LLC: NXPCS1670K-HUD {800V} (1,673,400 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.
What breaker and wire size does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} require?
At 1,294,180 W continuous AC (800 V, 3-phase), continuous current is 934.0 A; 125% NEC 690.8/705.12 sizing requires a 1,200 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} require?
At 1,294,180 W AC and 800 V, 3-phase, continuous line current is 934.0 A, requiring a 1,200 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.
How does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} compare to NEXTRACKER LLC: NXPCS1670K-HUD {800V}?
DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} delivers 1,294,180 W AC at 98.82% CEC efficiency with a 1,500 V DC ceiling, while NEXTRACKER LLC: NXPCS1670K-HUD {800V} outputs 1,673,400 W at 800 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)