Delta Electronics: DP350U-US-XX {800V} outputs 352,401 W AC at 800 V, 3-phase (254.3 A continuous, 400 A OCPD), ranking #81 of 2,343 CEC inverters at 98.48% efficiency with a 850-1,330 V MPPT window and 1,330 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 352,401 W
- AC Voltage
- 800 V, 3-phase
- Min PV Breaker
- 400 A (parallel Cu feeders)
- CEC Efficiency
- 98.48%
How Does Delta Electronics: DP350U-US-XX {800V} Compare Against Peer CEC Listings?
How Delta Electronics Delta Electronics: DP350U-US-XX {800V} compares on 98.48% efficiency, MPPT span, and 120% busbar interconnection. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
With a 850-1,330 V MPPT tracking band and 1,330 V DC ceiling, Delta Electronics: DP350U-US-XX {800V} handles 352,401 W continuous AC (32,401 W above the 320,000 W 800 V median). Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap. Installers comparing Delta Electronics against Chint Power Systems America: CPS SCH350KTL-DO/US-800 {800V} (350,000 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does Delta Electronics: DP350U-US-XX {800V} Fall Across Listed CEC Models?
Position of Delta Electronics: DP350U-US-XX {800V} (352,401 W AC) relative to the 7,680 W CEC median inverter. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Delta Electronics: DP350U-US-XX {800V}?
Percentile placement of Delta Electronics: DP350U-US-XX {800V} across AC power class, conversion efficiency, and backfeed breaker size. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Delta Electronics: DP350U-US-XX {800V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Delta Electronics: DP350U-US-XX {800V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
98.48% CEC Weighted Efficiency
+0.18 pts vs the 98.3% 800 V median; overall power rank #208 (352,401 W, top 8.9%; higher than 91.1% of peers).
400 A Required Backfeed OCPD
125% x 254.3 A = 317.9 A -> 400 A standard OCPD using parallel Cu feeders (75 C).
850 V - 1,330 V (Max 1,330 V DC)
Tracking span of 480.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 352401.0W / 800 V 3-phase -> 254.3 A | Breaker >= 1.25 * 254.3 = 317.9 A -> 400 A
CEC Inverters.csv for Delta Electronics: DP350U-US-XX {800V}: Paco=352401.0 W, Vac=800 V, Vdcmax=1330.0 V, Eff=98.48%.
Result: Min 400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (800V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for Delta Electronics: DP350U-US-XX {800V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Delta Electronics: DP350U-US-XX {800V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 352,401 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 800 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,330 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 850 V - 1,330 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 311.168 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.48% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Delta Electronics: DP350U-US-XX {800V} (800 V, 3-phase)?
Check whether Delta Electronics: DP350U-US-XX {800V} (400 A breaker) fits without main breaker derate or supply-side taps. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (800V) | 40 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (800V) | 80 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (800V) | 120 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (800V) | 160 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (800V) | 240 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With Delta Electronics: DP350U-US-XX {800V}?
Verified cold-weather (-10 C) series module counts matched to Delta Electronics: DP350U-US-XX {800V}'s 1,330 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 20 to 23 panels | 13.57 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 26 to 31 panels | 13.64 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 25 to 29 panels | 12.32 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 30 to 32 panels | 6.4 kW |
Which Competing Grid-Support Inverters Compare to Delta Electronics: DP350U-US-XX {800V}?
Alternative CEC inverters comparable to Delta Electronics: DP350U-US-XX {800V}, including Chint Power Systems America: CPS SCH350KTL-DO/US-800 {800V} (350,000 W) at 800 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: CPS SCH350KTL-DO/US-800 {800V} Chint Power Systems America |
350,000 W | -2401 W | 800.0 V | 1300.0 V | 98.38% |
| Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V} Ginlong Technologies Co Ltd |
348,488 W | -3913 W | 800.0 V | 1300.0 V | 98.47% |
| Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V} Ginlong Technologies Co Ltd |
348,153 W | -4248 W | 800.0 V | 1300.0 V | 98.47% |
| Sungrow Power Supply Co Ltd: SG350HX-US {800V} Sungrow Power Supply Co Ltd |
320,865 W | -31536 W | 800.0 V | 1330.0 V | 98.28% |
What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: DP350U-US-XX {800V}?
Check Delta Electronics: DP350U-US-XX {800V} (352,401 W AC, 400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,330 V DC on Delta Electronics: DP350U-US-XX {800V}.
Delta Electronics: DP350U-US-XX {800V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 400 A OCPD breaker (254.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.48%) and MPPT window (850-1,330 V) directly against Chint Power Systems America: CPS SCH350KTL-DO/US-800 {800V} (350,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Delta Electronics: DP350U-US-XX {800V} by Delta Electronics covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.
What breaker and wire size does Delta Electronics: DP350U-US-XX {800V} require?
At 352,401 W continuous AC (800 V, 3-phase), continuous current is 254.3 A; 125% NEC 690.8/705.12 sizing requires a 400 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does Delta Electronics: DP350U-US-XX {800V} require?
At 352,401 W AC and 800 V, 3-phase, continuous line current is 254.3 A, requiring a 400 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.
How does Delta Electronics: DP350U-US-XX {800V} compare to Chint Power Systems America: CPS SCH350KTL-DO/US-800 {800V}?
Delta Electronics: DP350U-US-XX {800V} delivers 352,401 W AC at 98.48% CEC efficiency with a 1,330 V DC ceiling, while Chint Power Systems America: CPS SCH350KTL-DO/US-800 {800V} outputs 350,000 W at 800 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)