NEXTRACKER LLC: NXPCS1670K-HUD {800V} outputs 1,673,400 W AC at 800 V, 3-phase (1207.7 A continuous, 1,550 A OCPD), ranking #290 of 2,343 CEC inverters at 98.11% efficiency with a 1,200-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,673,400 W
- AC Voltage
- 800 V, 3-phase
- Min PV Breaker
- 1,550 A (parallel Cu feeders)
- CEC Efficiency
- 98.11%
How Does NEXTRACKER LLC: NXPCS1670K-HUD {800V} Compare Against Peer CEC Listings?
Breaker sizing (1,550 A), parallel Cu feeders wire rules, and DC input limits for NEXTRACKER LLC: NXPCS1670K-HUD {800V}.
For NEC 705.12 solar interconnection, NEXTRACKER LLC: NXPCS1670K-HUD {800V} outputs 1207.7 A continuous AC at 800 V, 3-phase and needs a 1,550 A backfeed breaker on parallel Cu feeders (75 C). Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap. Conversion efficiency scores 98.11% (#290 of 2,343, +1.29 pts vs overall CEC median).
Where Does NEXTRACKER LLC: NXPCS1670K-HUD {800V} Fall Across Listed CEC Models?
Output power comparison showing where NEXTRACKER LLC: NXPCS1670K-HUD {800V} sits among all 2,343 CEC-listed grid-support inverters. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define NEXTRACKER LLC: NXPCS1670K-HUD {800V}?
Relative ranking of NEXTRACKER LLC: NXPCS1670K-HUD {800V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for NEXTRACKER LLC: NXPCS1670K-HUD {800V}?
Snapshot of NEXTRACKER LLC: NXPCS1670K-HUD {800V} efficiency rank (#290), OCPD breaker size, MPPT span, and busbar verdict. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
98.11% CEC Weighted Efficiency
-0.19 pts vs the 98.3% 800 V median; overall power rank #119 (1,673,400 W, top 5.1%; higher than 94.9% of peers).
1,550 A Required Backfeed OCPD
125% x 1207.7 A = 1509.6 A -> 1,550 A standard OCPD using parallel Cu feeders (75 C).
1,200 V - 1,500 V (Max 1,500 V DC)
Tracking span of 300.0 V; active in CEC directory (hybrid battery-capable inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1673400.0W / 800 V 3-phase -> 1207.7 A | Breaker >= 1.25 * 1207.7 = 1509.6 A -> 1,550 A
CEC Inverters.csv for NEXTRACKER LLC: NXPCS1670K-HUD {800V}: Paco=1673400.0 W, Vac=800 V, Vdcmax=1500.0 V, Eff=98.11%.
Result: Min 1,550 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (800V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for NEXTRACKER LLC: NXPCS1670K-HUD {800V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for NEXTRACKER LLC: NXPCS1670K-HUD {800V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,673,400 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 800 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 1,200 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1263.45 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.11% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to NEXTRACKER LLC: NXPCS1670K-HUD {800V} (800 V, 3-phase)?
NEC 705.12(B)(3)(2) backfeed compliance table for NEXTRACKER LLC: NXPCS1670K-HUD {800V} at 800 V, 3-phase. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (800V) | 40 A | 1,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (800V) | 80 A | 1,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (800V) | 120 A | 1,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (800V) | 160 A | 1,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (800V) | 240 A | 1,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which Competing Grid-Support Inverters Compare to NEXTRACKER LLC: NXPCS1670K-HUD {800V}?
Peer 800 V, 3-phase CEC inverters near 1,673,400 W AC output such as Sungrow Power Supply Co Ltd: SC2000UD-US {800V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Sungrow Power Supply Co Ltd: SC2000UD-US {800V} Sungrow Power Supply Co Ltd |
2,014,870 W | +341470 W | 800.0 V | 1500.0 V | 97.8% |
| DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V} DYNAPOWER COMPANY LLC |
1,294,180 W | -379220 W | 800.0 V | 1500.0 V | 98.82% |
| Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V} Sichuan Clou Energy Electric Co Ltd |
2,299,960 W | +626560 W | 800.0 V | 1500.0 V | 98.5% |
| Delta Electronics: DP350U-US-XX {800V} Delta Electronics |
352,401 W | -1320999 W | 800.0 V | 1330.0 V | 98.48% |
What Are the Interconnection Limits and Best-Fit Uses for NEXTRACKER LLC: NXPCS1670K-HUD {800V}?
Check NEXTRACKER LLC: NXPCS1670K-HUD {800V} (1,673,400 W AC, 1,550 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on NEXTRACKER LLC: NXPCS1670K-HUD {800V}.
NEXTRACKER LLC: NXPCS1670K-HUD {800V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 1,550 A OCPD breaker (1207.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.11%) and MPPT window (1,200-1,500 V) directly against Sungrow Power Supply Co Ltd: SC2000UD-US {800V} (2,014,870 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for NEXTRACKER LLC: NXPCS1670K-HUD {800V} by NEXTRACKER LLC covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.
What breaker and wire size does NEXTRACKER LLC: NXPCS1670K-HUD {800V} require?
At 1,673,400 W continuous AC (800 V, 3-phase), continuous current is 1207.7 A; 125% NEC 690.8/705.12 sizing requires a 1,550 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does NEXTRACKER LLC: NXPCS1670K-HUD {800V} require?
At 1,673,400 W AC and 800 V, 3-phase, continuous line current is 1207.7 A, requiring a 1,550 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.
How does NEXTRACKER LLC: NXPCS1670K-HUD {800V} compare to Sungrow Power Supply Co Ltd: SC2000UD-US {800V}?
NEXTRACKER LLC: NXPCS1670K-HUD {800V} delivers 1,673,400 W AC at 98.11% CEC efficiency with a 1,500 V DC ceiling, while Sungrow Power Supply Co Ltd: SC2000UD-US {800V} outputs 2,014,870 W at 800 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)