NEXTRACKER LLC: NXPCS3340K-HUD {800V} — CEC Inverter Specifications

Manufacturer: NEXTRACKER LLC Registry: CEC Verified Engineering Specification

NEXTRACKER LLC: NXPCS3340K-HUD {800V} outputs 3,347,800 W AC at 800 V, 3-phase (2416.1 A continuous, 3,050 A OCPD), ranking #238 of 2,343 CEC inverters at 98.21% efficiency with a 1,200-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,347,800 W
AC Voltage
800 V, 3-phase
Min PV Breaker
3,050 A (parallel Cu feeders)
CEC Efficiency
98.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does NEXTRACKER LLC: NXPCS3340K-HUD {800V} Compare Against Peer CEC Listings?

Breaker sizing (3,050 A), parallel Cu feeders wire rules, and DC input limits for NEXTRACKER LLC: NXPCS3340K-HUD {800V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), NEXTRACKER LLC: NXPCS3340K-HUD {800V} requires 3020.1 A design capacity -> 3,050 A breaker using parallel Cu feeders copper at 75 C terminals. Weighted efficiency sits at 98.21% (+1.39 pts vs overall CEC median) across 2,343 CEC models, while commercial 800 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (800v) or nec 705.11 supply-side tap.

Where Does NEXTRACKER LLC: NXPCS3340K-HUD {800V} Fall Across Listed CEC Models?

Output power comparison showing where NEXTRACKER LLC: NXPCS3340K-HUD {800V} sits among all 2,343 CEC-listed grid-support inverters. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where NEXTRACKER LLC: NXPCS3340K-HUD {800V} (3,347,800 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACNEXTRACKER LLC: NX: 3,347,800 W

What Dataset Percentiles Define NEXTRACKER LLC: NXPCS3340K-HUD {800V}?

Relative ranking of NEXTRACKER LLC: NXPCS3340K-HUD {800V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

NEXTRACKER LLC: NXPCS3340K-HUD {800V} Technical ThresholdsPercentile comparison for NEXTRACKER LLC: NXPCS3340K-HUD {800V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,347,800 WCEC Efficiency98.21%Backfeed Breaker3,050 A

What Do the Dataset Ranks Show for NEXTRACKER LLC: NXPCS3340K-HUD {800V}?

Snapshot of NEXTRACKER LLC: NXPCS3340K-HUD {800V} efficiency rank (#238), OCPD breaker size, MPPT span, and busbar verdict. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Eff #238 / 2,343

98.21% CEC Weighted Efficiency

-0.09 pts vs the 98.3% 800 V median; overall power rank #33 (3,347,800 W, top 1.4%; higher than 98.6% of peers).

NEC 705.12 Check

3,050 A Required Backfeed OCPD

125% x 2416.1 A = 3020.1 A -> 3,050 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,200 V - 1,500 V (Max 1,500 V DC)

Tracking span of 300.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3347800.0W / 800 V 3-phase -> 2416.1 A | Breaker >= 1.25 * 2416.1 = 3020.1 A -> 3,050 A

CEC Inverters.csv for NEXTRACKER LLC: NXPCS3340K-HUD {800V}: Paco=3347800.0 W, Vac=800 V, Vdcmax=1500.0 V, Eff=98.21%.

Result: Min 3,050 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (800V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for NEXTRACKER LLC: NXPCS3340K-HUD {800V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for NEXTRACKER LLC: NXPCS3340K-HUD {800V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for NEXTRACKER LLC: NXPCS3340K-HUD {800V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,347,800 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 800 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,200 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 2525.18 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.21% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to NEXTRACKER LLC: NXPCS3340K-HUD {800V} (800 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for NEXTRACKER LLC: NXPCS3340K-HUD {800V} at 800 V, 3-phase. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Evaluates NEXTRACKER LLC: NXPCS3340K-HUD {800V} (3050 A required OCPD at 800 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (800V) 40 A 3,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (800V) 80 A 3,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (800V) 120 A 3,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (800V) 160 A 3,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (800V) 240 A 3,050 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to NEXTRACKER LLC: NXPCS3340K-HUD {800V}?

Peer 800 V, 3-phase CEC inverters near 3,347,800 W AC output such as Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V}
Sichuan Clou Energy Electric Co Ltd
2,299,960 W -1047840 W 800.0 V 1500.0 V 98.5%
Sungrow Power Supply Co Ltd: SC2000UD-US {800V}
Sungrow Power Supply Co Ltd
2,014,870 W -1332930 W 800.0 V 1500.0 V 97.8%
DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}
DYNAPOWER COMPANY LLC
1,294,180 W -2053620 W 800.0 V 1500.0 V 98.82%
Delta Electronics: DP350U-US-XX {800V}
Delta Electronics
352,401 W -2995399 W 800.0 V 1330.0 V 98.48%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for NEXTRACKER LLC: NXPCS3340K-HUD {800V}?

Check NEXTRACKER LLC: NXPCS3340K-HUD {800V} (3,347,800 W AC, 3,050 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on NEXTRACKER LLC: NXPCS3340K-HUD {800V}.

NEXTRACKER LLC: NXPCS3340K-HUD {800V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 3,050 A OCPD breaker (2416.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.21%) and MPPT window (1,200-1,500 V) directly against Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V} (2,299,960 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for NEXTRACKER LLC: NXPCS3340K-HUD {800V} by NEXTRACKER LLC covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.

What breaker and wire size does NEXTRACKER LLC: NXPCS3340K-HUD {800V} require?

At 3,347,800 W continuous AC (800 V, 3-phase), continuous current is 2416.1 A; 125% NEC 690.8/705.12 sizing requires a 3,050 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does NEXTRACKER LLC: NXPCS3340K-HUD {800V} require?

At 3,347,800 W AC and 800 V, 3-phase, continuous line current is 2416.1 A, requiring a 3,050 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.

How does NEXTRACKER LLC: NXPCS3340K-HUD {800V} compare to Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V}?

NEXTRACKER LLC: NXPCS3340K-HUD {800V} delivers 3,347,800 W AC at 98.21% CEC efficiency with a 1,500 V DC ceiling, while Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V} outputs 2,299,960 W at 800 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.