Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Sungrow Power Supply Co Ltd: SC2000UD-US {800V} — CEC Inverter Specifications

Manufacturer: Sungrow Power Supply Co Ltd Registry: CEC Verified Engineering Specification

Sungrow Power Supply Co Ltd: SC2000UD-US {800V} outputs 2,014,870 W AC at 800 V, 3-phase (1454.1 A continuous, 1,850 A OCPD), ranking #422 of 2,343 CEC inverters at 97.8% efficiency with a 1,150-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,014,870 W
AC Voltage
800 V, 3-phase
Min PV Breaker
1,850 A (parallel Cu feeders)
CEC Efficiency
97.8%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sungrow Power Supply Co Ltd: SC2000UD-US {800V} Compare Against Peer CEC Listings?

CEC efficiency rank (#422), 1,150-1,500 V MPPT tracking, and panel fit for Sungrow Power Supply Co Ltd: SC2000UD-US {800V}.

Sungrow Power Supply Co Ltd: SC2000UD-US {800V} from Sungrow Power Supply Co Ltd outputs 1454.1 A continuous AC at 800 V, 3-phase (2,014,870 W AC, rank #101). Paired with parallel Cu feeders conductors and a 1,850 A OCPD, its 97.8% CEC efficiency compares closely with Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V} (2,299,960 W). Keep NEC 690.7 winter string Voc below 1,500 V DC.

Where Does Sungrow Power Supply Co Ltd: SC2000UD-US {800V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Sungrow Power Supply Co Ltd: SC2000UD-US {800V} at 2,014,870 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sungrow Power Supply Co Ltd: SC2000UD-US {800V} (2,014,870 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSungrow Power Supp: 2,014,870 W

What Dataset Percentiles Define Sungrow Power Supply Co Ltd: SC2000UD-US {800V}?

Dataset percentiles comparing Sungrow Power Supply Co Ltd: SC2000UD-US {800V} against 2,343 certified grid-support inverters nationwide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sungrow Power Supply Co Ltd: SC2000UD-US {800V} Technical ThresholdsPercentile comparison for Sungrow Power Supply Co Ltd: SC2000UD-US {800V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,014,870 WCEC Efficiency97.8%Backfeed Breaker1,850 A

What Do the Dataset Ranks Show for Sungrow Power Supply Co Ltd: SC2000UD-US {800V}?

Engineering highlights for Sungrow Power Supply Co Ltd: SC2000UD-US {800V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #422 / 2,343

97.8% CEC Weighted Efficiency

-0.50 pts vs the 98.3% 800 V median; overall power rank #101 (2,014,870 W, top 4.3%; higher than 95.7% of peers).

NEC 705.12 Check

1,850 A Required Backfeed OCPD

125% x 1454.1 A = 1817.6 A -> 1,850 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,150 V - 1,500 V (Max 1,500 V DC)

Tracking span of 350.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2014870.0W / 800 V 3-phase -> 1454.1 A | Breaker >= 1.25 * 1454.1 = 1817.6 A -> 1,850 A

CEC Inverters.csv for Sungrow Power Supply Co Ltd: SC2000UD-US {800V}: Paco=2014870.0 W, Vac=800 V, Vdcmax=1500.0 V, Eff=97.8%.

Result: Min 1,850 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (800V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Sungrow Power Supply Co Ltd: SC2000UD-US {800V}?

California Energy Commission Solar Equipment List parameters for Sungrow Power Supply Co Ltd: SC2000UD-US {800V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Sungrow Power Supply Co Ltd: SC2000UD-US {800V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,014,870 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 800 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,150 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1648.16 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.8% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Sungrow Power Supply Co Ltd: SC2000UD-US {800V} (800 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Sungrow Power Supply Co Ltd: SC2000UD-US {800V} (1,850 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Sungrow Power Supply Co Ltd: SC2000UD-US {800V} (1850 A required OCPD at 800 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (800V) 40 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (800V) 80 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (800V) 120 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (800V) 160 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (800V) 240 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Sungrow Power Supply Co Ltd: SC2000UD-US {800V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Sungrow Power Supply Co Ltd: SC2000UD-US {800V}.

Sampled CEC PV modules aligned within 1150.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 35 panels (fixed) 15.4 kW

Which Competing Grid-Support Inverters Compare to Sungrow Power Supply Co Ltd: SC2000UD-US {800V}?

Four alternative CEC inverters matched to Sungrow Power Supply Co Ltd: SC2000UD-US {800V} (2,014,870 W AC), led by Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V}
Sichuan Clou Energy Electric Co Ltd
2,299,960 W +285090 W 800.0 V 1500.0 V 98.5%
NEXTRACKER LLC: NXPCS1670K-HUD {800V}
NEXTRACKER LLC
1,673,400 W -341470 W 800.0 V 1500.0 V 98.11%
DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V}
DYNAPOWER COMPANY LLC
1,294,180 W -720690 W 800.0 V 1500.0 V 98.82%
NEXTRACKER LLC: NXPCS800K-HUD {800V}
NEXTRACKER LLC
801,420 W -1213450 W 800.0 V 1500.0 V 97.97%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sungrow Power Supply Co Ltd: SC2000UD-US {800V}?

Check Sungrow Power Supply Co Ltd: SC2000UD-US {800V} (2,014,870 W AC, 1,850 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on Sungrow Power Supply Co Ltd: SC2000UD-US {800V}.

Sungrow Power Supply Co Ltd: SC2000UD-US {800V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,850 A OCPD breaker (1454.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.8%) and MPPT window (1,150-1,500 V) directly against Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V} (2,299,960 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sungrow Power Supply Co Ltd: SC2000UD-US {800V} by Sungrow Power Supply Co Ltd covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.

What breaker and wire size does Sungrow Power Supply Co Ltd: SC2000UD-US {800V} require?

At 2,014,870 W continuous AC (800 V, 3-phase), continuous current is 1454.1 A; 125% NEC 690.8/705.12 sizing requires a 1,850 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Sungrow Power Supply Co Ltd: SC2000UD-US {800V} require?

At 2,014,870 W AC and 800 V, 3-phase, continuous line current is 1454.1 A, requiring a 1,850 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.

How does Sungrow Power Supply Co Ltd: SC2000UD-US {800V} compare to Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V}?

Sungrow Power Supply Co Ltd: SC2000UD-US {800V} delivers 2,014,870 W AC at 97.8% CEC efficiency with a 1,500 V DC ceiling, while Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V} outputs 2,299,960 W at 800 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.