NEXTRACKER LLC: NXPCS800K-HUD {800V} — CEC Inverter Specifications

Manufacturer: NEXTRACKER LLC Registry: CEC Verified Engineering Specification

NEXTRACKER LLC: NXPCS800K-HUD {800V} outputs 801,420 W AC at 800 V, 3-phase (578.4 A continuous, 750 A OCPD), ranking #357 of 2,343 CEC inverters at 97.97% efficiency with a 1,200-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
801,420 W
AC Voltage
800 V, 3-phase
Min PV Breaker
750 A (parallel Cu feeders)
CEC Efficiency
97.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does NEXTRACKER LLC: NXPCS800K-HUD {800V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 800 V, 3-phase grid-support overview for NEXTRACKER LLC: NXPCS800K-HUD {800V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rated at 801,420 W AC (578.4 A continuous), NEXTRACKER LLC: NXPCS800K-HUD {800V} ranks #357 of 2,343 CEC units at 97.97% efficiency (-0.33 pts vs the 98.3% 800 V median). Minimum 75 C copper conductor sizing for its 750 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 1,500 V DC at record local winter lows.

Where Does NEXTRACKER LLC: NXPCS800K-HUD {800V} Fall Across Listed CEC Models?

Marks NEXTRACKER LLC: NXPCS800K-HUD {800V} (801,420 W AC) across the California Energy Commission inverter AC capacity distribution. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where NEXTRACKER LLC: NXPCS800K-HUD {800V} (801,420 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACNEXTRACKER LLC: NX: 801,420 W

What Dataset Percentiles Define NEXTRACKER LLC: NXPCS800K-HUD {800V}?

Benchmarks NEXTRACKER LLC: NXPCS800K-HUD {800V} continuous AC output, 97.97% CEC weighted efficiency, and 750 A OCPD breaker demand.

NEXTRACKER LLC: NXPCS800K-HUD {800V} Technical ThresholdsPercentile comparison for NEXTRACKER LLC: NXPCS800K-HUD {800V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output801,420 WCEC Efficiency97.97%Backfeed Breaker750 A

What Do the Dataset Ranks Show for NEXTRACKER LLC: NXPCS800K-HUD {800V}?

Four key NEC 705.12 and California Energy Commission metrics defining NEXTRACKER LLC: NXPCS800K-HUD {800V} by NEXTRACKER LLC. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Eff #357 / 2,343

97.97% CEC Weighted Efficiency

-0.33 pts vs the 98.3% 800 V median; overall power rank #179 (801,420 W, top 7.6%; higher than 92.4% of peers).

NEC 705.12 Check

750 A Required Backfeed OCPD

125% x 578.4 A = 723.0 A -> 750 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,200 V - 1,500 V (Max 1,500 V DC)

Tracking span of 300.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 801420.0W / 800 V 3-phase -> 578.4 A | Breaker >= 1.25 * 578.4 = 723.0 A -> 750 A

CEC Inverters.csv for NEXTRACKER LLC: NXPCS800K-HUD {800V}: Paco=801420.0 W, Vac=800 V, Vdcmax=1500.0 V, Eff=97.97%.

Result: Min 750 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (800V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for NEXTRACKER LLC: NXPCS800K-HUD {800V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for NEXTRACKER LLC: NXPCS800K-HUD {800V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for NEXTRACKER LLC: NXPCS800K-HUD {800V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 801,420 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 800 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,200 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 605.973 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.97% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to NEXTRACKER LLC: NXPCS800K-HUD {800V} (800 V, 3-phase)?

Evaluates NEXTRACKER LLC: NXPCS800K-HUD {800V} (750 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates NEXTRACKER LLC: NXPCS800K-HUD {800V} (750 A required OCPD at 800 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (800V) 40 A 750 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (800V) 80 A 750 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (800V) 120 A 750 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (800V) 160 A 750 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (800V) 240 A 750 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to NEXTRACKER LLC: NXPCS800K-HUD {800V}?

Competing CEC grid-support inverters near 801,420 W AC and 800 V, 3-phase, led by Delta Electronics: DP350U-US-XX {800V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: DP350U-US-XX {800V}
Delta Electronics
352,401 W -449019 W 800.0 V 1330.0 V 98.48%
Chint Power Systems America: CPS SCH350KTL-DO/US-800 {800V}
Chint Power Systems America
350,000 W -451420 W 800.0 V 1300.0 V 98.38%
Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V}
Ginlong Technologies Co Ltd
348,488 W -452932 W 800.0 V 1300.0 V 98.47%
Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V}
Ginlong Technologies Co Ltd
348,153 W -453267 W 800.0 V 1300.0 V 98.47%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for NEXTRACKER LLC: NXPCS800K-HUD {800V}?

Check NEXTRACKER LLC: NXPCS800K-HUD {800V} (801,420 W AC, 750 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on NEXTRACKER LLC: NXPCS800K-HUD {800V}.

NEXTRACKER LLC: NXPCS800K-HUD {800V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 750 A OCPD breaker (578.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.97%) and MPPT window (1,200-1,500 V) directly against Delta Electronics: DP350U-US-XX {800V} (352,401 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for NEXTRACKER LLC: NXPCS800K-HUD {800V} by NEXTRACKER LLC covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.

What breaker and wire size does NEXTRACKER LLC: NXPCS800K-HUD {800V} require?

At 801,420 W continuous AC (800 V, 3-phase), continuous current is 578.4 A; 125% NEC 690.8/705.12 sizing requires a 750 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does NEXTRACKER LLC: NXPCS800K-HUD {800V} require?

At 801,420 W AC and 800 V, 3-phase, continuous line current is 578.4 A, requiring a 750 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.

How does NEXTRACKER LLC: NXPCS800K-HUD {800V} compare to Delta Electronics: DP350U-US-XX {800V}?

NEXTRACKER LLC: NXPCS800K-HUD {800V} delivers 801,420 W AC at 97.97% CEC efficiency with a 1,500 V DC ceiling, while Delta Electronics: DP350U-US-XX {800V} outputs 352,401 W at 800 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.