Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Sungrow Power Supply Co Ltd: SC2500UD-US {900V} — CEC Inverter Specifications

Manufacturer: Sungrow Power Supply Co Ltd Registry: CEC Verified Engineering Specification

Sungrow Power Supply Co Ltd: SC2500UD-US {900V} outputs 2,507,230 W AC at 900 V, 3-phase (1608.4 A continuous, 2,050 A OCPD), ranking #422 of 2,343 CEC inverters at 97.8% efficiency with a 1,300-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,507,230 W
AC Voltage
900 V, 3-phase
Min PV Breaker
2,050 A (parallel Cu feeders)
CEC Efficiency
97.8%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sungrow Power Supply Co Ltd: SC2500UD-US {900V} Compare Against Peer CEC Listings?

How Sungrow Power Supply Co Ltd Sungrow Power Supply Co Ltd: SC2500UD-US {900V} compares on 97.8% efficiency, MPPT span, and 120% busbar interconnection.

With a 1,300-1,500 V MPPT tracking band and 1,500 V DC ceiling, Sungrow Power Supply Co Ltd: SC2500UD-US {900V} handles 2,507,230 W continuous AC (47,560 W below the 2,554,790 W 900 V median). Commercial 900 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (900V) or NEC 705.11 supply-side tap. Installers comparing Sungrow Power Supply Co Ltd against INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} (2,467,620 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

Where Does Sungrow Power Supply Co Ltd: SC2500UD-US {900V} Fall Across Listed CEC Models?

Position of Sungrow Power Supply Co Ltd: SC2500UD-US {900V} (2,507,230 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sungrow Power Supply Co Ltd: SC2500UD-US {900V} (2,507,230 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSungrow Power Supp: 2,507,230 W

What Dataset Percentiles Define Sungrow Power Supply Co Ltd: SC2500UD-US {900V}?

Percentile placement of Sungrow Power Supply Co Ltd: SC2500UD-US {900V} across AC power class, conversion efficiency, and backfeed breaker size.

Sungrow Power Supply Co Ltd: SC2500UD-US {900V} Technical ThresholdsPercentile comparison for Sungrow Power Supply Co Ltd: SC2500UD-US {900V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,507,230 WCEC Efficiency97.8%Backfeed Breaker2,050 A

What Do the Dataset Ranks Show for Sungrow Power Supply Co Ltd: SC2500UD-US {900V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Sungrow Power Supply Co Ltd: SC2500UD-US {900V}.

Eff #422 / 2,343

97.8% CEC Weighted Efficiency

-0.31 pts vs the 98.11% 900 V median; overall power rank #78 (2,507,230 W, top 3.3%; higher than 96.7% of peers).

NEC 705.12 Check

2,050 A Required Backfeed OCPD

125% x 1608.4 A = 2010.5 A -> 2,050 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,300 V - 1,500 V (Max 1,500 V DC)

Tracking span of 200.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 900 V, 3-phase switchgear (200A Bus / 200A Main (900V) to 1,200A Bus / 1,200A Main (900V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2507230.0W / 900 V 3-phase -> 1608.4 A | Breaker >= 1.25 * 1608.4 = 2010.5 A -> 2,050 A

CEC Inverters.csv for Sungrow Power Supply Co Ltd: SC2500UD-US {900V}: Paco=2507230.0 W, Vac=900 V, Vdcmax=1500.0 V, Eff=97.8%.

Result: Min 2,050 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (900V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Sungrow Power Supply Co Ltd: SC2500UD-US {900V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Sungrow Power Supply Co Ltd: SC2500UD-US {900V}.

Official California Energy Commission (NREL SAM) test parameters for Sungrow Power Supply Co Ltd: SC2500UD-US {900V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,507,230 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 900 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,300 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1899.04 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.8% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Sungrow Power Supply Co Ltd: SC2500UD-US {900V} (900 V, 3-phase)?

Check whether Sungrow Power Supply Co Ltd: SC2500UD-US {900V} (2,050 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Sungrow Power Supply Co Ltd: SC2500UD-US {900V} (2050 A required OCPD at 900 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (900V) 40 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (900V) 80 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (900V) 120 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (900V) 160 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (900V) 240 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to Sungrow Power Supply Co Ltd: SC2500UD-US {900V}?

Alternative CEC inverters comparable to Sungrow Power Supply Co Ltd: SC2500UD-US {900V}, including INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} (2,467,620 W) at 900 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}
INGETEAM POWER TECHNOLOGY SA
2,467,620 W -39610 W 480.0 V 1300.0 V 96.63%
Power Electronics: FS2250CU15O3 {600V}
Power Electronics
2,420,370 W -86860 W 600.0 V 1200.0 V 97.82%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W -780530 W 690.0 V 1500.0 V 98.32%
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W -841230 W 575.0 V 1200.0 V 97.54%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sungrow Power Supply Co Ltd: SC2500UD-US {900V}?

Check Sungrow Power Supply Co Ltd: SC2500UD-US {900V} (2,507,230 W AC, 2,050 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 900 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (900V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on Sungrow Power Supply Co Ltd: SC2500UD-US {900V}.

Sungrow Power Supply Co Ltd: SC2500UD-US {900V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,050 A OCPD breaker (1608.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.8%) and MPPT window (1,300-1,500 V) directly against INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} (2,467,620 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sungrow Power Supply Co Ltd: SC2500UD-US {900V} by Sungrow Power Supply Co Ltd covering breaker sizing, MPPT limits, and 900 V, 3-phase interconnection.

What breaker and wire size does Sungrow Power Supply Co Ltd: SC2500UD-US {900V} require?

At 2,507,230 W continuous AC (900 V, 3-phase), continuous current is 1608.4 A; 125% NEC 690.8/705.12 sizing requires a 2,050 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Sungrow Power Supply Co Ltd: SC2500UD-US {900V} require?

At 2,507,230 W AC and 900 V, 3-phase, continuous line current is 1608.4 A, requiring a 2,050 A OCPD and 1,200A Bus / 1,200A Main (900V) or NEC 705.11 interconnection.

How does Sungrow Power Supply Co Ltd: SC2500UD-US {900V} compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}?

Sungrow Power Supply Co Ltd: SC2500UD-US {900V} delivers 2,507,230 W AC at 97.8% CEC efficiency with a 1,500 V DC ceiling, while INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} outputs 2,467,620 W at 900 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.