Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} — CEC Inverter Specifications

Manufacturer: DYNAPOWER COMPANY LLC Registry: CEC Verified Engineering Specification

DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} outputs 2,212,640 W AC at 690 V, 3-phase (1851.5 A continuous, 2,350 A OCPD), ranking #419 of 2,343 CEC inverters at 97.82% efficiency with a 1,150-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,212,640 W
AC Voltage
690 V, 3-phase
Min PV Breaker
2,350 A (parallel Cu feeders)
CEC Efficiency
97.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} Compare Against Peer CEC Listings?

Breaker sizing (2,350 A), parallel Cu feeders wire rules, and DC input limits for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}.

For NEC 705.12 solar interconnection, DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} outputs 1851.5 A continuous AC at 690 V, 3-phase and needs a 2,350 A backfeed breaker on parallel Cu feeders (75 C). Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap. Conversion efficiency scores 97.82% (#419 of 2,343, +1.00 pts vs overall CEC median).

Where Does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} Fall Across Listed CEC Models?

Output power comparison showing where DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} (2,212,640 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDYNAPOWER COMPANY : 2,212,640 W

What Dataset Percentiles Define DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}?

Relative ranking of DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} Technical ThresholdsPercentile comparison for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,212,640 WCEC Efficiency97.82%Backfeed Breaker2,350 A

What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}?

Snapshot of DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} efficiency rank (#419), OCPD breaker size, MPPT span, and busbar verdict.

Eff #419 / 2,343

97.82% CEC Weighted Efficiency

-0.35 pts vs the 98.17% 690 V median; overall power rank #92 (2,212,640 W, top 3.9%; higher than 96.1% of peers).

NEC 705.12 Check

2,350 A Required Backfeed OCPD

125% x 1851.5 A = 2314.4 A -> 2,350 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,150 V - 1,500 V (Max 1,500 V DC)

Tracking span of 350.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2212640.0W / 690 V 3-phase -> 1851.5 A | Breaker >= 1.25 * 1851.5 = 2314.4 A -> 2,350 A

CEC Inverters.csv for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}: Paco=2212640.0 W, Vac=690 V, Vdcmax=1500.0 V, Eff=97.82%.

Result: Min 2,350 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}.

Official California Energy Commission (NREL SAM) test parameters for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,212,640 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 690 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,150 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1809.5 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.82% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} (690 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} at 690 V, 3-phase.

Evaluates DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} (2350 A required OCPD at 690 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (690V) 40 A 2,350 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (690V) 80 A 2,350 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (690V) 120 A 2,350 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (690V) 160 A 2,350 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (690V) 240 A 2,350 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}?

Minimum and maximum series solar module strings fitting DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} MPPT and 1,500 V limits.

Sampled CEC PV modules aligned within 1150.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 35 panels (fixed) 15.4 kW

Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}?

Peer 690 V, 3-phase CEC inverters near 2,212,640 W AC output such as Power Electronics: FS2125CU15 {690V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Power Electronics: FS2125CU15 {690V}
Power Electronics
2,306,410 W +93770 W 690.0 V 1200.0 V 97.94%
SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
2,003,820 W -208820 W 690.0 V 1500.0 V 98.14%
Sichuan Clou Energy Electric Co Ltd: NEPCS-2000 {690V}
Sichuan Clou Energy Electric Co Ltd
2,000,400 W -212240 W 690.0 V 1500.0 V 98.54%
Power Electronics: FS1700CU15 {690V}
Power Electronics
1,850,630 W -362010 W 690.0 V 1200.0 V 97.9%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}?

Check DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} (2,212,640 W AC, 2,350 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}.

DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,350 A OCPD breaker (1851.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.82%) and MPPT window (1,150-1,500 V) directly against Power Electronics: FS2125CU15 {690V} (2,306,410 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.

What breaker and wire size does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} require?

At 2,212,640 W continuous AC (690 V, 3-phase), continuous current is 1851.5 A; 125% NEC 690.8/705.12 sizing requires a 2,350 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} require?

At 2,212,640 W AC and 690 V, 3-phase, continuous line current is 1851.5 A, requiring a 2,350 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.

How does DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} compare to Power Electronics: FS2125CU15 {690V}?

DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V} delivers 2,212,640 W AC at 97.82% CEC efficiency with a 1,500 V DC ceiling, while Power Electronics: FS2125CU15 {690V} outputs 2,306,410 W at 690 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.