Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} — CEC Inverter Specifications

Manufacturer: DYNAPOWER COMPANY LLC Registry: CEC Verified Engineering Specification

DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} outputs 1,199,640 W AC at 480 V, 3-phase (1443.0 A continuous, 1,850 A OCPD), ranking #1,865 of 2,343 CEC inverters at 96.13% efficiency with a 740-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,199,640 W
AC Voltage
480 V, 3-phase
Min PV Breaker
1,850 A (parallel Cu feeders)
CEC Efficiency
96.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} Compare Against Peer CEC Listings?

How DYNAPOWER COMPANY LLC DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} compares on 96.13% efficiency, MPPT span, and 120% busbar interconnection.

With a 740-1,500 V MPPT tracking band and 1,500 V DC ceiling, DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} handles 1,199,640 W continuous AC (1,149,640 W above the 50,000 W 480 V median). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Installers comparing DYNAPOWER COMPANY LLC against Delta Electronics: EPCS-1200US {480V} (1,216,710 W) should verify whether listed since 2024-03-21 grid-support firmware meets local IEEE 1547 utility rules.

Where Does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} Fall Across Listed CEC Models?

Position of DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (1,199,640 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (1,199,640 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDYNAPOWER COMPANY : 1,199,640 W

What Dataset Percentiles Define DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?

Percentile placement of DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} across AC power class, conversion efficiency, and backfeed breaker size.

DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} Technical ThresholdsPercentile comparison for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,199,640 WCEC Efficiency96.13%Backfeed Breaker1,850 A

What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}.

Eff #1,865 / 2,343

96.13% CEC Weighted Efficiency

-1.89 pts vs the 98.02% 480 V median; overall power rank #150 (1,199,640 W, top 6.4%; higher than 93.6% of peers).

NEC 705.12 Check

1,850 A Required Backfeed OCPD

125% x 1443.0 A = 1803.8 A -> 1,850 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

740 V - 1,500 V (Max 1,500 V DC)

Tracking span of 760.0 V; listed since 2024-03-21 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1199640.0W / 480 V 3-phase -> 1443.0 A | Breaker >= 1.25 * 1443.0 = 1803.8 A -> 1,850 A

CEC Inverters.csv for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}: Paco=1199640.0 W, Vac=480 V, Vdcmax=1500.0 V, Eff=96.13%.

Result: Min 1,850 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (480V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}.

Official California Energy Commission (NREL SAM) test parameters for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,199,640 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 740 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1247.94 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.13% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-03-21 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (480 V, 3-phase)?

Check whether DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (1,850 A breaker) fits without main breaker derate or supply-side taps.

Evaluates DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (1850 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (480V) 160 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (480V) 240 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?

Verified cold-weather (-10 C) series module counts matched to DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}'s 1,500 V DC ceiling.

Sampled CEC PV modules aligned within 740.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 18 to 26 panels 15.34 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 23 to 35 panels 15.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 22 to 33 panels 14.03 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 26 to 36 panels 7.2 kW

Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?

Alternative CEC inverters comparable to DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}, including Delta Electronics: EPCS-1200US {480V} (1,216,710 W) at 480 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: EPCS-1200US {480V}
Delta Electronics
1,216,710 W +17070 W 480.0 V 1500.0 V 97.82%
EPC Power Corp: 50-100181 {480V}
EPC Power Corp
1,044,200 W -155440 W 480.0 V 1500.0 V 97.49%
EPC Power Corp: 50-100100 {480V}
EPC Power Corp
1,036,840 W -162800 W 480.0 V 1250.0 V 95.42%
Delta Electronics: DWE2100-US {480V}
Delta Electronics
1,887,740 W +688100 W 480.0 V 1200.0 V 96.67%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?

Check DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (1,199,640 W AC, 1,850 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}.

DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,850 A OCPD breaker (1443.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.13%) and MPPT window (740-1,500 V) directly against Delta Electronics: EPCS-1200US {480V} (1,216,710 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} require?

At 1,199,640 W continuous AC (480 V, 3-phase), continuous current is 1443.0 A; 125% NEC 690.8/705.12 sizing requires a 1,850 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} require?

At 1,199,640 W AC and 480 V, 3-phase, continuous line current is 1443.0 A, requiring a 1,850 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} compare to Delta Electronics: EPCS-1200US {480V}?

DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} delivers 1,199,640 W AC at 96.13% CEC efficiency with a 1,500 V DC ceiling, while Delta Electronics: EPCS-1200US {480V} outputs 1,216,710 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.