DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} outputs 1,199,640 W AC at 480 V, 3-phase (1443.0 A continuous, 1,850 A OCPD), ranking #1,865 of 2,343 CEC inverters at 96.13% efficiency with a 740-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,199,640 W
- AC Voltage
- 480 V, 3-phase
- Min PV Breaker
- 1,850 A (parallel Cu feeders)
- CEC Efficiency
- 96.13%
How Does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} Compare Against Peer CEC Listings?
How DYNAPOWER COMPANY LLC DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} compares on 96.13% efficiency, MPPT span, and 120% busbar interconnection.
With a 740-1,500 V MPPT tracking band and 1,500 V DC ceiling, DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} handles 1,199,640 W continuous AC (1,149,640 W above the 50,000 W 480 V median). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Installers comparing DYNAPOWER COMPANY LLC against Delta Electronics: EPCS-1200US {480V} (1,216,710 W) should verify whether listed since 2024-03-21 grid-support firmware meets local IEEE 1547 utility rules.
Where Does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} Fall Across Listed CEC Models?
Position of DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (1,199,640 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?
Percentile placement of DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}.
96.13% CEC Weighted Efficiency
-1.89 pts vs the 98.02% 480 V median; overall power rank #150 (1,199,640 W, top 6.4%; higher than 93.6% of peers).
1,850 A Required Backfeed OCPD
125% x 1443.0 A = 1803.8 A -> 1,850 A standard OCPD using parallel Cu feeders (75 C).
740 V - 1,500 V (Max 1,500 V DC)
Tracking span of 760.0 V; listed since 2024-03-21 (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1199640.0W / 480 V 3-phase -> 1443.0 A | Breaker >= 1.25 * 1443.0 = 1803.8 A -> 1,850 A
CEC Inverters.csv for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}: Paco=1199640.0 W, Vac=480 V, Vdcmax=1500.0 V, Eff=96.13%.
Result: Min 1,850 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (480V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,199,640 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 740 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1247.94 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.13% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2024-03-21 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (480 V, 3-phase)?
Check whether DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (1,850 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (480V) | 40 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (480V) | 80 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (480V) | 120 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (480V) | 160 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (480V) | 240 A | 1,850 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?
Verified cold-weather (-10 C) series module counts matched to DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}'s 1,500 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 18 to 26 panels | 15.34 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 23 to 35 panels | 15.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 22 to 33 panels | 14.03 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 26 to 36 panels | 7.2 kW |
Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?
Alternative CEC inverters comparable to DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}, including Delta Electronics: EPCS-1200US {480V} (1,216,710 W) at 480 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: EPCS-1200US {480V} Delta Electronics |
1,216,710 W | +17070 W | 480.0 V | 1500.0 V | 97.82% |
| EPC Power Corp: 50-100181 {480V} EPC Power Corp |
1,044,200 W | -155440 W | 480.0 V | 1500.0 V | 97.49% |
| EPC Power Corp: 50-100100 {480V} EPC Power Corp |
1,036,840 W | -162800 W | 480.0 V | 1250.0 V | 95.42% |
| Delta Electronics: DWE2100-US {480V} Delta Electronics |
1,887,740 W | +688100 W | 480.0 V | 1200.0 V | 96.67% |
What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}?
Check DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} (1,199,640 W AC, 1,850 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V}.
DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 1,850 A OCPD breaker (1443.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.13%) and MPPT window (740-1,500 V) directly against Delta Electronics: EPCS-1200US {480V} (1,216,710 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.
What breaker and wire size does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} require?
At 1,199,640 W continuous AC (480 V, 3-phase), continuous current is 1443.0 A; 125% NEC 690.8/705.12 sizing requires a 1,850 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} require?
At 1,199,640 W AC and 480 V, 3-phase, continuous line current is 1443.0 A, requiring a 1,850 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.
How does DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} compare to Delta Electronics: EPCS-1200US {480V}?
DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V} delivers 1,199,640 W AC at 96.13% CEC efficiency with a 1,500 V DC ceiling, while Delta Electronics: EPCS-1200US {480V} outputs 1,216,710 W at 480 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)