Manufacturer: SINENG ELECTRIC CO LTD Registry: CEC Verified Engineering Specification

SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} outputs 2,003,820 W AC at 690 V, 3-phase (1676.7 A continuous, 2,100 A OCPD), ranking #277 of 2,343 CEC inverters at 98.14% efficiency with a 1,000-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,003,820 W
AC Voltage
690 V, 3-phase
Min PV Breaker
2,100 A (parallel Cu feeders)
CEC Efficiency
98.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 690 V, 3-phase grid-support overview for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}.

Ranking #102 of 2,343 CEC inverters (top 4.4%; higher than 95.6% of peers), SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} is a grid-tied PV inverter delivering 2,003,820 W continuous AC at 690 V, 3-phase (1676.7 A continuous). Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.14% (-0.03 pts vs the 98.17% 690 V median) against peers like Sichuan Clou Energy Electric Co Ltd: NEPCS-2000 {690V} (2,000,400 W).

Where Does SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} Fall Across Listed CEC Models?

Marks SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} (2,003,820 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} (2,003,820 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSINENG ELECTRIC CO: 2,003,820 W

What Dataset Percentiles Define SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}?

Benchmarks SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} continuous AC output, 98.14% CEC weighted efficiency, and 2,100 A OCPD breaker demand.

SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} Technical ThresholdsPercentile comparison for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,003,820 WCEC Efficiency98.14%Backfeed Breaker2,100 A

What Do the Dataset Ranks Show for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}?

Four key NEC 705.12 and California Energy Commission metrics defining SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} by SINENG ELECTRIC CO LTD.

Eff #277 / 2,343

98.14% CEC Weighted Efficiency

-0.03 pts vs the 98.17% 690 V median; overall power rank #102 (2,003,820 W, top 4.4%; higher than 95.6% of peers).

NEC 705.12 Check

2,100 A Required Backfeed OCPD

125% x 1676.7 A = 2095.9 A -> 2,100 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,000 V - 1,500 V (Max 1,500 V DC)

Tracking span of 500.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2003820.0W / 690 V 3-phase -> 1676.7 A | Breaker >= 1.25 * 1676.7 = 2095.9 A -> 2,100 A

CEC Inverters.csv for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}: Paco=2003820.0 W, Vac=690 V, Vdcmax=1500.0 V, Eff=98.14%.

Result: Min 2,100 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}.

Official California Energy Commission (NREL SAM) test parameters for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,003,820 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 690 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,000 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1633.38 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.14% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} (690 V, 3-phase)?

Evaluates SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} (2,100 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} (2100 A required OCPD at 690 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (690V) 40 A 2,100 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (690V) 80 A 2,100 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (690V) 120 A 2,100 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (690V) 160 A 2,100 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (690V) 240 A 2,100 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}?

Sample PV string lengths aligned within 1,000-1,500 V MPPT and 1,500 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 1000.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 24 to 26 panels 15.34 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 30 to 35 panels 15.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 30 to 33 panels 14.03 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 35 to 36 panels 7.2 kW

Which Competing Grid-Support Inverters Compare to SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}?

Competing CEC grid-support inverters near 2,003,820 W AC and 690 V, 3-phase, led by Sichuan Clou Energy Electric Co Ltd: NEPCS-2000 {690V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Sichuan Clou Energy Electric Co Ltd: NEPCS-2000 {690V}
Sichuan Clou Energy Electric Co Ltd
2,000,400 W -3420 W 690.0 V 1500.0 V 98.54%
Power Electronics: FS1700CU15 {690V}
Power Electronics
1,850,630 W -153190 W 690.0 V 1200.0 V 97.9%
DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V}
DYNAPOWER COMPANY LLC
2,212,640 W +208820 W 690.0 V 1500.0 V 97.82%
SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}
SYL (NINGBO) Battery Co Ltd
1,751,510 W -252310 W 690.0 V 1500.0 V 98.44%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}?

Check SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} (2,003,820 W AC, 2,100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V}.

SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,100 A OCPD breaker (1676.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.14%) and MPPT window (1,000-1,500 V) directly against Sichuan Clou Energy Electric Co Ltd: NEPCS-2000 {690V} (2,000,400 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} by SINENG ELECTRIC CO LTD covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.

What breaker and wire size does SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} require?

At 2,003,820 W continuous AC (690 V, 3-phase), continuous current is 1676.7 A; 125% NEC 690.8/705.12 sizing requires a 2,100 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} require?

At 2,003,820 W AC and 690 V, 3-phase, continuous line current is 1676.7 A, requiring a 2,100 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.

How does SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} compare to Sichuan Clou Energy Electric Co Ltd: NEPCS-2000 {690V}?

SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V} delivers 2,003,820 W AC at 98.14% CEC efficiency with a 1,500 V DC ceiling, while Sichuan Clou Energy Electric Co Ltd: NEPCS-2000 {690V} outputs 2,000,400 W at 690 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.