SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} — CEC Inverter Specifications

Manufacturer: SYL (NINGBO) Battery Co Ltd Registry: CEC Verified Engineering Specification

SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} outputs 1,751,510 W AC at 690 V, 3-phase (1465.6 A continuous, 1,850 A OCPD), ranking #101 of 2,343 CEC inverters at 98.44% efficiency with a 1,000-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,751,510 W
AC Voltage
690 V, 3-phase
Min PV Breaker
1,850 A (parallel Cu feeders)
CEC Efficiency
98.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} Compare Against Peer CEC Listings?

Breaker sizing (1,850 A), parallel Cu feeders wire rules, and DC input limits for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}.

For NEC 705.12 solar interconnection, SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} outputs 1465.6 A continuous AC at 690 V, 3-phase and needs a 1,850 A backfeed breaker on parallel Cu feeders (75 C). Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap. Conversion efficiency scores 98.44% (#101 of 2,343, +1.62 pts vs overall CEC median).

Where Does SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} Fall Across Listed CEC Models?

Output power comparison showing where SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} (1,751,510 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSYL (NINGBO) Batte: 1,751,510 W

What Dataset Percentiles Define SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}?

Relative ranking of SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} Technical ThresholdsPercentile comparison for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,751,510 WCEC Efficiency98.44%Backfeed Breaker1,850 A

What Do the Dataset Ranks Show for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}?

Snapshot of SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} efficiency rank (#101), OCPD breaker size, MPPT span, and busbar verdict.

Eff #101 / 2,343

98.44% CEC Weighted Efficiency

+0.27 pts vs the 98.17% 690 V median; overall power rank #110 (1,751,510 W, top 4.7%; higher than 95.3% of peers).

NEC 705.12 Check

1,850 A Required Backfeed OCPD

125% x 1465.6 A = 1832.0 A -> 1,850 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,000 V - 1,500 V (Max 1,500 V DC)

Tracking span of 500.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1751510.0W / 690 V 3-phase -> 1465.6 A | Breaker >= 1.25 * 1465.6 = 1832.0 A -> 1,850 A

CEC Inverters.csv for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}: Paco=1751510.0 W, Vac=690 V, Vdcmax=1500.0 V, Eff=98.44%.

Result: Min 1,850 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}.

Official California Energy Commission (NREL SAM) test parameters for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,751,510 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 690 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,000 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1547.14 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.44% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} (690 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} at 690 V, 3-phase.

Evaluates SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} (1850 A required OCPD at 690 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (690V) 40 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (690V) 80 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (690V) 120 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (690V) 160 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (690V) 240 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}?

Minimum and maximum series solar module strings fitting SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} MPPT and 1,500 V limits.

Sampled CEC PV modules aligned within 1000.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 24 to 26 panels 15.34 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 30 to 35 panels 15.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 30 to 33 panels 14.03 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 35 to 36 panels 7.2 kW

Which Competing Grid-Support Inverters Compare to SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}?

Peer 690 V, 3-phase CEC inverters near 1,751,510 W AC output such as Sungrow Power Supply Co Ltd: SC1725UD-US {690V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Sungrow Power Supply Co Ltd: SC1725UD-US {690V}
Sungrow Power Supply Co Ltd
1,728,406 W -23104 W 690.0 V 1500.0 V 98.38%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W -24810 W 690.0 V 1500.0 V 98.32%
Delta Electronics: EPCS-1725US {690V}
Delta Electronics
1,725,451 W -26059 W 690.0 V 1500.0 V 98.25%
Shenzhen Sinexcel Electric Co Ltd: PWS1-1725KTL-H-NA-8M8 {690V}
Shenzhen Sinexcel Electric Co Ltd
1,710,710 W -40800 W 690.0 V 1450.0 V 92.8%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}?

Check SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} (1,751,510 W AC, 1,850 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}.

SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,850 A OCPD breaker (1465.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.44%) and MPPT window (1,000-1,500 V) directly against Sungrow Power Supply Co Ltd: SC1725UD-US {690V} (1,728,406 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} by SYL (NINGBO) Battery Co Ltd covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.

What breaker and wire size does SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} require?

At 1,751,510 W continuous AC (690 V, 3-phase), continuous current is 1465.6 A; 125% NEC 690.8/705.12 sizing requires a 1,850 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} require?

At 1,751,510 W AC and 690 V, 3-phase, continuous line current is 1465.6 A, requiring a 1,850 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.

How does SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} compare to Sungrow Power Supply Co Ltd: SC1725UD-US {690V}?

SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} delivers 1,751,510 W AC at 98.44% CEC efficiency with a 1,500 V DC ceiling, while Sungrow Power Supply Co Ltd: SC1725UD-US {690V} outputs 1,728,406 W at 690 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.