Manufacturer: Power Electronics Registry: CEC Verified Engineering Specification

Power Electronics: FS1700CU15 {690V} outputs 1,850,630 W AC at 690 V, 3-phase (1548.5 A continuous, 1,950 A OCPD), ranking #383 of 2,343 CEC inverters at 97.9% efficiency with a 976-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,850,630 W
AC Voltage
690 V, 3-phase
Min PV Breaker
1,950 A (parallel Cu feeders)
CEC Efficiency
97.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Power Electronics: FS1700CU15 {690V} Compare Against Peer CEC Listings?

CEC efficiency rank (#383), 976-1,200 V MPPT tracking, and panel fit for Power Electronics: FS1700CU15 {690V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Operating at 690 V, 3-phase, Power Electronics: FS1700CU15 {690V} converts DC array energy at 97.9% CEC weighted efficiency (top 16.4%; higher than 83.6% of peers) with a 1,200 V max DC input and 1835.35 A max input current for NEC 690.7 string safety. Compare this 1,850,630 W grid-tied PV inverter directly with SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} (1,751,510 W). Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.

Where Does Power Electronics: FS1700CU15 {690V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Power Electronics: FS1700CU15 {690V} at 1,850,630 W continuous AC output. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Power Electronics: FS1700CU15 {690V} (1,850,630 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACPower Electronics:: 1,850,630 W

What Dataset Percentiles Define Power Electronics: FS1700CU15 {690V}?

Dataset percentiles comparing Power Electronics: FS1700CU15 {690V} against 2,343 certified grid-support inverters nationwide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Power Electronics: FS1700CU15 {690V} Technical ThresholdsPercentile comparison for Power Electronics: FS1700CU15 {690V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,850,630 WCEC Efficiency97.9%Backfeed Breaker1,950 A

What Do the Dataset Ranks Show for Power Electronics: FS1700CU15 {690V}?

Engineering highlights for Power Electronics: FS1700CU15 {690V} covering efficiency, parallel Cu feeders feeder, and panel compatibility. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #383 / 2,343

97.9% CEC Weighted Efficiency

-0.27 pts vs the 98.17% 690 V median; overall power rank #108 (1,850,630 W, top 4.6%; higher than 95.4% of peers).

NEC 705.12 Check

1,950 A Required Backfeed OCPD

125% x 1548.5 A = 1935.6 A -> 1,950 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

976 V - 1,200 V (Max 1,200 V DC)

Tracking span of 224.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1850630.0W / 690 V 3-phase -> 1548.5 A | Breaker >= 1.25 * 1548.5 = 1935.6 A -> 1,950 A

CEC Inverters.csv for Power Electronics: FS1700CU15 {690V}: Paco=1850630.0 W, Vac=690 V, Vdcmax=1200.0 V, Eff=97.9%.

Result: Min 1,950 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Power Electronics: FS1700CU15 {690V}?

California Energy Commission Solar Equipment List parameters for Power Electronics: FS1700CU15 {690V} (grid-tied PV inverter) interconnection. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for Power Electronics: FS1700CU15 {690V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,850,630 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 690 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 976 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1835.35 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.9% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Power Electronics: FS1700CU15 {690V} (690 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Power Electronics: FS1700CU15 {690V} (1,950 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Power Electronics: FS1700CU15 {690V} (1950 A required OCPD at 690 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (690V) 40 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (690V) 80 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (690V) 120 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (690V) 160 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (690V) 240 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to Power Electronics: FS1700CU15 {690V}?

Four alternative CEC inverters matched to Power Electronics: FS1700CU15 {690V} (1,850,630 W AC), led by SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}
SYL (NINGBO) Battery Co Ltd
1,751,510 W -99120 W 690.0 V 1500.0 V 98.44%
Sungrow Power Supply Co Ltd: SC1725UD-US {690V}
Sungrow Power Supply Co Ltd
1,728,406 W -122224 W 690.0 V 1500.0 V 98.38%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W -123930 W 690.0 V 1500.0 V 98.32%
Delta Electronics: EPCS-1725US {690V}
Delta Electronics
1,725,451 W -125179 W 690.0 V 1500.0 V 98.25%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS1700CU15 {690V}?

Check Power Electronics: FS1700CU15 {690V} (1,850,630 W AC, 1,950 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS1700CU15 {690V}.

Power Electronics: FS1700CU15 {690V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,950 A OCPD breaker (1548.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.9%) and MPPT window (976-1,200 V) directly against SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} (1,751,510 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Power Electronics: FS1700CU15 {690V} by Power Electronics covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.

What breaker and wire size does Power Electronics: FS1700CU15 {690V} require?

At 1,850,630 W continuous AC (690 V, 3-phase), continuous current is 1548.5 A; 125% NEC 690.8/705.12 sizing requires a 1,950 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Power Electronics: FS1700CU15 {690V} require?

At 1,850,630 W AC and 690 V, 3-phase, continuous line current is 1548.5 A, requiring a 1,950 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.

How does Power Electronics: FS1700CU15 {690V} compare to SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V}?

Power Electronics: FS1700CU15 {690V} delivers 1,850,630 W AC at 97.9% CEC efficiency with a 1,200 V DC ceiling, while SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V} outputs 1,751,510 W at 690 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.