Skip to main content
WireAndSun
Calculators
CEC PV Module

US Solar USS-QCMO3-72-290 — CEC Solar Module Specifications

Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMO3-72-290 is a 290.0 W STC (262.8 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.92% efficiency, 44.4 V Voc at 25 C, and 49.43 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
262.8 W
Voc @ 25C
44.4 V
Efficiency
14.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMO3-72-290 Compare Against Peer CEC Listings?

Engineering position of US Solar USS-QCMO3-72-290 (290.0 W STC) vs. Centrosolar America DM72 290 across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, US Solar USS-QCMO3-72-290 pairs typical 90.6% PTC-to-STC thermal output (262.8 W real-world rating) with 44.4 V nominal Voc. An 8 kW residential build (8,120 W DC, 7,358 W PTC) saves ~$2,032/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM72 290 offers a 290.0 W alternative.

Where Does US Solar USS-QCMO3-72-290 Fall Across Listed CEC Models?

Plots US Solar USS-QCMO3-72-290 at 290.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMO3-72-290 (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMO3: 290.0 W

What Dataset Percentiles Define US Solar USS-QCMO3-72-290?

Benchmarks US Solar USS-QCMO3-72-290 on STC wattage, thermal PTC/STC retention, and 14.92 aperture conversion efficiency against CEC peers.

US Solar USS-QCMO3-72-290 Engineering BenchmarksPercentile comparison of US Solar USS-QCMO3-72-290 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention90.6%Module Efficiency14.92%

What Do the Dataset Ranks Show for US Solar USS-QCMO3-72-290?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for US Solar USS-QCMO3-72-290 by US Solar.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,877

14.92% Aperture Efficiency

Power density 149.2 W/m2 (4.99 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.43 V at -10 C (593.2 V string) and 50.87 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.4 m2 (586 sq ft) producing 7,358 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.4 * (1 + (-0.324/100) * (-10 - 25)) = 49.43 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for US Solar USS-QCMO3-72-290: Voc=44.4 V, beta_Voc=-0.324%/C, Isc=8.6 A, STC=290.0 W, Area=1.944 m2.

Result: 12 panels max on 600 V (593.2 V); 28 panels for 8 kW (586 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMO3-72-290?

Laboratory test ratings recorded for US Solar USS-QCMO3-72-290 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMO3-72-290.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 262.8 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.3 V / 8.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.92% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many US Solar USS-QCMO3-72-290 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (586 sq ft at 8 kW), and estimated Year-1 electric bill offset for US Solar USS-QCMO3-72-290.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 439 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 586 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 732 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Sibling wattage bins and frame colors grouped with US Solar USS-QCMO3-72-290 under US Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the US Solar USS-QCMO3-72-290 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
US Solar USS-QCMO3-72-285 285.0 W 258.2 W 44.1 V 35.7 V 14.66%
US Solar USS-QCMO3-72-290 290.0 W 262.8 W 44.4 V 36.3 V 14.92%
US Solar USS-QCMO3-72-295 295.0 W 267.5 W 44.7 V 36.5 V 15.17%

How Many US Solar USS-QCMO3-72-290 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for US Solar USS-QCMO3-72-290 (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=44.4V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.87 V 11 panels 559.6 V 19 panels
-10 C (14 F) 49.43 V 12 panels 593.2 V 20 panels
0 C (32 F) 48.0 V 12 panels 576.0 V 20 panels
25 C (77 F STC) 44.4 V 13 panels 577.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMO3-72-290?

Closest cross-brand CEC competitors to US Solar USS-QCMO3-72-290 matched near 290.0 W STC and 44.4 V Voc, led by Centrosolar America DM72 290.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 290
Centrosolar America
290.0 W Tie (0 W) 44.4 V 14.92% 90.6%
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
AXITEC AC-290M/156-72S
AXITEC
290.0 W Tie (0 W) 44.98 V 14.95% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMO3-72-290?

Evaluate US Solar USS-QCMO3-72-290 (290.0 W STC, 44.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMO3-72-290 reaches 50.87 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 586 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (586 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMO3-72-290 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMO3-72-290 8 kW Residential Fit

Needs 28 modules (586 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 290.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 262.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMO3-72-290 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMO3-72-290?

Multiplying US Solar USS-QCMO3-72-290's 8.6 A short-circuit current by 1.56 equals 13.42 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can US Solar USS-QCMO3-72-290 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.43 V cold Voc at 14 F and handles 8.6 A Isc; string inverters cap US Solar USS-QCMO3-72-290 at 12 panels on 600 V.

Is US Solar USS-QCMO3-72-290 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMO3-72-290 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls