Skip to main content
WireAndSun
Calculators
CEC PV Module

US Solar USS-QCMO3-60-275 — CEC Solar Module Specifications

Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMO3-60-275 is a 275.0 W STC (250.0 W PTC) Mono-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.77% efficiency, 39.1 V Voc at 25 C, and 43.53 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
250.0 W
Voc @ 25C
39.1 V
Efficiency
16.77%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMO3-60-275 Compare Against Peer CEC Listings?

Engineering position of US Solar USS-QCMO3-60-275 (275.0 W STC) vs. Centrosolar America DM60 275 across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, US Solar USS-QCMO3-60-275 pairs typical 90.9% PTC-to-STC thermal output (250.0 W real-world rating) with 39.1 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,500 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM60 275 offers a 275.0 W alternative.

Where Does US Solar USS-QCMO3-60-275 Fall Across Listed CEC Models?

Plots US Solar USS-QCMO3-60-275 at 275.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMO3-60-275 (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMO3: 275.0 W

What Dataset Percentiles Define US Solar USS-QCMO3-60-275?

Benchmarks US Solar USS-QCMO3-60-275 on STC wattage, thermal PTC/STC retention, and 16.77 aperture conversion efficiency against CEC peers.

US Solar USS-QCMO3-60-275 Engineering BenchmarksPercentile comparison of US Solar USS-QCMO3-60-275 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention90.9%Module Efficiency16.77%

What Do the Dataset Ranks Show for US Solar USS-QCMO3-60-275?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for US Solar USS-QCMO3-60-275 by US Solar.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,838

16.77% Aperture Efficiency

Power density 167.7 W/m2 (3.14 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.53 V at -10 C (565.9 V string) and 44.8 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 49.2 m2 (530 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.1 * (1 + (-0.324/100) * (-10 - 25)) = 43.53 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for US Solar USS-QCMO3-60-275: Voc=39.1 V, beta_Voc=-0.324%/C, Isc=9.0 A, STC=275.0 W, Area=1.64 m2.

Result: 13 panels max on 600 V (565.9 V); 30 panels for 8 kW (530 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMO3-60-275?

Laboratory test ratings recorded for US Solar USS-QCMO3-60-275 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMO3-60-275.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 250.0 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.8 V / 8.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.77% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many US Solar USS-QCMO3-60-275 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (530 sq ft at 8 kW), and estimated Year-1 electric bill offset for US Solar USS-QCMO3-60-275.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 388 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 530 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 653 sq ft $2,548 $4,308

How Many US Solar USS-QCMO3-60-275 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for US Solar USS-QCMO3-60-275 (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=39.1V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.8 V 13 panels 582.4 V 22 panels
-10 C (14 F) 43.53 V 13 panels 565.9 V 22 panels
0 C (32 F) 42.27 V 14 panels 591.8 V 23 panels
25 C (77 F STC) 39.1 V 15 panels 586.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMO3-60-275?

Closest cross-brand CEC competitors to US Solar USS-QCMO3-60-275 matched near 275.0 W STC and 39.1 V Voc, led by Centrosolar America DM60 275.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM60 275
Centrosolar America
275.0 W Tie (0 W) 39.1 V 16.77% 90.9%
Flextronics FXS-275BB-SAC1B
Flextronics
275.0 W Tie (0 W) 38.6 V 16.75% 91.4%
AXITEC AC-275P/60S
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
AXITEC AC-275P/60V
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMO3-60-275?

Evaluate US Solar USS-QCMO3-60-275 (275.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMO3-60-275 reaches 44.8 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 530 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (530 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMO3-60-275 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMO3-60-275 8 kW Residential Fit

Needs 30 modules (530 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America DM60 275.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMO3-60-275 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMO3-60-275?

Multiplying US Solar USS-QCMO3-60-275's 9.0 A short-circuit current by 1.56 equals 14.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can US Solar USS-QCMO3-60-275 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.53 V cold Voc at 14 F and handles 9.0 A Isc; string inverters cap US Solar USS-QCMO3-60-275 at 13 panels on 600 V.

Is US Solar USS-QCMO3-60-275 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMO3-60-275 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.