Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DM60 275 is a 275.0 W STC (250.0 W PTC) Mono-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.77% efficiency, 39.1 V Voc at 25 C, and 43.53 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
250.0 W
Voc @ 25C
39.1 V
Efficiency
16.77%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DM60 275 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Centrosolar America DM60 275 (Mono-c-Si) residential solar systems.

Homeowners evaluating Centrosolar America DM60 275 need 22 panels for 6 kW or 30 panels (530 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (530 sq ft). Under NEC 690.7(A), beta_Voc (-0.324%/C) pushes open-circuit voltage to 43.53 V at 14 F and 44.8 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Centrosolar America DM60 275 Fall Across Listed CEC Models?

Comparison of Centrosolar America DM60 275 (275.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DM60 275 (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 275.0 W

What Dataset Percentiles Define Centrosolar America DM60 275?

Relative ranking of Centrosolar America DM60 275 across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency.

Centrosolar America DM60 275 Engineering BenchmarksPercentile comparison of Centrosolar America DM60 275 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention90.9%Module Efficiency16.77%

What Do the Dataset Ranks Show for Centrosolar America DM60 275?

Summary of Centrosolar America DM60 275 output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,838

16.77% Aperture Efficiency

Power density 167.7 W/m2 (3.14 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.53 V at -10 C (565.9 V string) and 44.8 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 49.2 m2 (530 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.1 * (1 + (-0.324/100) * (-10 - 25)) = 43.53 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for Centrosolar America DM60 275: Voc=39.1 V, beta_Voc=-0.324%/C, Isc=9.0 A, STC=275.0 W, Area=1.64 m2.

Result: 13 panels max on 600 V (565.9 V); 30 panels for 8 kW (530 sq ft).

What Are the Published CEC Specifications for Centrosolar America DM60 275?

Complete CEC test sheet for Centrosolar America DM60 275 including Isc (9.0 A), Voc (39.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DM60 275.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 250.0 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.8 V / 8.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.77% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Centrosolar America DM60 275 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Centrosolar America DM60 275.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 388 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 530 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 653 sq ft $2,548 $4,308

How Many Centrosolar America DM60 275 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Centrosolar America DM60 275 (39.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=39.1V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.8 V 13 panels 582.4 V 22 panels
-10 C (14 F) 43.53 V 13 panels 565.9 V 22 panels
0 C (32 F) 42.27 V 14 panels 591.8 V 23 panels
25 C (77 F STC) 39.1 V 15 panels 586.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DM60 275?

Four comparable CEC modules such as Flextronics FXS-275BB-SAC1B (275.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Flextronics FXS-275BB-SAC1B
Flextronics
275.0 W Tie (0 W) 38.6 V 16.75% 91.4%
AXITEC AC-275P/60S
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
AXITEC AC-275P/60V
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
GCL System Integration Technology Co Ltd GCL-M6/60275
GCL System Integration Technology Co Ltd
275.0 W Tie (0 W) 38.5 V 16.87% 90.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DM60 275?

Evaluate Centrosolar America DM60 275 (275.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DM60 275 reaches 44.8 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 530 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (530 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DM60 275 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DM60 275 8 kW Residential Fit

Needs 30 modules (530 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Flextronics FXS-275BB-SAC1B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DM60 275 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Centrosolar America DM60 275 PTC wattage (250.0 W) lower than STC (275.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 250.0 W PTC (90.9% retention) across Centrosolar America DM60 275's 1.64 m2 aperture.

Who should skip Centrosolar America DM60 275 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 Centrosolar America DM60 275 panels (530 sq ft) leave unusable roof gaps vs. Flextronics FXS-275BB-SAC1B.

What is the 1,000 V commercial string limit for Centrosolar America DM60 275?

On 1,000 V commercial inverters at -10 C (43.53 V cold Voc), Centrosolar America DM60 275 fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America DM60 275.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.