GCL System Integration Technology Co Ltd GCL-M6/60275 is a 275.0 W STC (247.6 W PTC) Mono-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.87% efficiency, 38.5 V Voc at 25 C, and 42.92 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 247.6 W
- Voc @ 25C
- 38.5 V
- Efficiency
- 16.87%
How Does GCL System Integration Technology Co Ltd GCL-M6/60275 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for GCL System Integration Technology Co Ltd GCL-M6/60275 (Mono-c-Si) residential solar systems.
GCL System Integration Technology Co Ltd GCL-M6/60275 delivers 168.7 W/m2 (3.04 percentage points below 19.91% CEC median) and typical 90.0% PTC-to-STC thermal output (247.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (526 sq ft). At -4 F (-20 C), string voltage climbs to 44.18 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with AXITEC AC-275P/60S (275.0 W).
Where Does GCL System Integration Technology Co Ltd GCL-M6/60275 Fall Across Listed CEC Models?
Comparison of GCL System Integration Technology Co Ltd GCL-M6/60275 (275.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-M6/60275?
Relative ranking of GCL System Integration Technology Co Ltd GCL-M6/60275 across nameplate watts, 90.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-M6/60275?
Summary of GCL System Integration Technology Co Ltd GCL-M6/60275 output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.87% Aperture Efficiency
Power density 168.7 W/m2 (3.04 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.92 V at -10 C (558.0 V string) and 44.18 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 48.9 m2 (526 sq ft) producing 7,428 W PTC; NEC 690.8 OCPD floor is 14.63 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.5 * (1 + (-0.328/100) * (-10 - 25)) = 42.92 V | OCPD = 1.56 * 9.38 = 14.63 A
Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-M6/60275: Voc=38.5 V, beta_Voc=-0.328%/C, Isc=9.38 A, STC=275.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (558.0 V); 30 panels for 8 kW (526 sq ft).
What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-M6/60275?
Complete CEC test sheet for GCL System Integration Technology Co Ltd GCL-M6/60275 including Isc (9.38 A), Voc (38.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 247.6 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.38 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.4 V / 8.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.328 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.87% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many GCL System Integration Technology Co Ltd GCL-M6/60275 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using GCL System Integration Technology Co Ltd GCL-M6/60275.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 386 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 526 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 649 sq ft | $2,548 | $4,308 |
How Many GCL System Integration Technology Co Ltd GCL-M6/60275 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for GCL System Integration Technology Co Ltd GCL-M6/60275 (38.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.18 V | 13 panels | 574.3 V | 22 panels |
| -10 C (14 F) | 42.92 V | 13 panels | 558.0 V | 23 panels |
| 0 C (32 F) | 41.66 V | 14 panels | 583.2 V | 24 panels |
| 25 C (77 F STC) | 38.5 V | 15 panels | 577.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-M6/60275?
Four comparable CEC modules such as AXITEC AC-275P/60S (275.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-275P/60S AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| AXITEC AC-275P/60V AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| Flextronics FXS-275BB-SAC1B Flextronics |
275.0 W | Tie (0 W) | 38.6 V | 16.75% | 91.4% |
| Anhui Rinengzhongtian Semiconductor Development QJP275-60 Anhui Rinengzhongtian Semiconductor Development |
275.0 W | Tie (0 W) | 38.01 V | 16.9% | 90.8% |
What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-M6/60275?
Evaluate GCL System Integration Technology Co Ltd GCL-M6/60275 (275.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-M6/60275 reaches 44.18 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 526 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (526 sq ft).
- 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-M6/60275 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GCL System Integration Technology Co Ltd GCL-M6/60275 8 kW Residential Fit
Needs 30 modules (526 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-275P/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 247.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GCL System Integration Technology Co Ltd GCL-M6/60275 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many GCL System Integration Technology Co Ltd GCL-M6/60275 panels fit on a 600 V winter solar string?
At -10 C (14 F), GCL System Integration Technology Co Ltd GCL-M6/60275 cold Voc rises from 38.5 V to 42.92 V (beta_Voc -0.328%/C), capping a 600 V string at 13 panels (558.0 V).
How much roof area does an 8 kW array of GCL System Integration Technology Co Ltd GCL-M6/60275 need?
An 8 kW DC system uses 30 GCL System Integration Technology Co Ltd GCL-M6/60275 modules (8,250 W STC / 7,428 W PTC), covering roughly 526 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does GCL System Integration Technology Co Ltd GCL-M6/60275 compare against AXITEC AC-275P/60S?
GCL System Integration Technology Co Ltd GCL-M6/60275 outputs 275.0 W STC (38.5 V Voc, rank #18,259 of 21,677), while AXITEC AC-275P/60S delivers 275.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)