Skip to main content
WireAndSun
Calculators
CEC PV Module

Flextronics FXS-275BB-SAC1B — CEC Solar Module Specifications

Manufacturer: Flextronics Registry: CEC Verified Engineering Specification

Flextronics FXS-275BB-SAC1B is a 275.0 W STC (251.3 W PTC) Mono-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.75% efficiency, 38.6 V Voc at 25 C, and 42.92 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
251.3 W
Voc @ 25C
38.6 V
Efficiency
16.75%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Flextronics FXS-275BB-SAC1B Compare Against Peer CEC Listings?

How Flextronics Flextronics FXS-275BB-SAC1B handles rooftop heat (251.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Flextronics FXS-275BB-SAC1B exhibits 9.2 A short-circuit current, requiring a 14.35 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,259 of 21,677 (135.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 49.2 m2 for an 8 kW system (37 panels for 10 kW). Lower 38.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does Flextronics FXS-275BB-SAC1B Fall Across Listed CEC Models?

Where Flextronics FXS-275BB-SAC1B (275.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Flextronics FXS-275BB-SAC1B (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFlextronics FXS-27: 275.0 W

What Dataset Percentiles Define Flextronics FXS-275BB-SAC1B?

Percentile placement of Flextronics FXS-275BB-SAC1B across power density (167.6 W/m2), thermal retention, and nameplate STC wattage. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Flextronics FXS-275BB-SAC1B Engineering BenchmarksPercentile comparison of Flextronics FXS-275BB-SAC1B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention91.4%Module Efficiency16.75%

What Do the Dataset Ranks Show for Flextronics FXS-275BB-SAC1B?

Four critical engineering numbers homeowners and solar installers check first when reviewing Flextronics FXS-275BB-SAC1B specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,887

16.75% Aperture Efficiency

Power density 167.6 W/m2 (3.16 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.92 V at -10 C (558.0 V string) and 44.16 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 49.2 m2 (530 sq ft) producing 7,539 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.6 * (1 + (-0.32/100) * (-10 - 25)) = 42.92 V | OCPD = 1.56 * 9.2 = 14.35 A

Inputs from CEC Modules.csv for Flextronics FXS-275BB-SAC1B: Voc=38.6 V, beta_Voc=-0.32%/C, Isc=9.2 A, STC=275.0 W, Area=1.641 m2.

Result: 13 panels max on 600 V (558.0 V); 30 panels for 8 kW (530 sq ft).

What Are the Published CEC Specifications for Flextronics FXS-275BB-SAC1B?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Flextronics FXS-275BB-SAC1B. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Flextronics FXS-275BB-SAC1B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 251.3 W (91.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.6 V / 8.72 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.75% (1.641 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Flextronics FXS-275BB-SAC1B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Flextronics FXS-275BB-SAC1B (275.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 389 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 530 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 654 sq ft $2,548 $4,308

How Many Flextronics FXS-275BB-SAC1B Modules Fit in a Cold-Weather String?

Maximum series module counts for Flextronics FXS-275BB-SAC1B from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.6V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.16 V 13 panels 574.1 V 22 panels
-10 C (14 F) 42.92 V 13 panels 558.0 V 23 panels
0 C (32 F) 41.69 V 14 panels 583.7 V 23 panels
25 C (77 F STC) 38.6 V 15 panels 579.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Flextronics FXS-275BB-SAC1B?

Alternative CEC solar modules from competing brands near Flextronics FXS-275BB-SAC1B (275.0 W), including AXITEC AC-275P/60S. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-275P/60S
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
AXITEC AC-275P/60V
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
GCL System Integration Technology Co Ltd GCL-M6/60275
GCL System Integration Technology Co Ltd
275.0 W Tie (0 W) 38.5 V 16.87% 90.0%
GCL System Integration Technology Co Ltd GCL-P6/60275
GCL System Integration Technology Co Ltd
275.0 W Tie (0 W) 38.5 V 16.9% 90.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Flextronics FXS-275BB-SAC1B?

Evaluate Flextronics FXS-275BB-SAC1B (275.0 W STC, 38.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Flextronics FXS-275BB-SAC1B reaches 44.16 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 530 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (530 sq ft).
  • 2026 tax credit baseline: cash residential installs of Flextronics FXS-275BB-SAC1B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Flextronics FXS-275BB-SAC1B 8 kW Residential Fit

Needs 30 modules (530 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-275P/60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 251.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Flextronics FXS-275BB-SAC1B by Flextronics grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Why is Flextronics FXS-275BB-SAC1B PTC wattage (251.3 W) lower than STC (275.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 251.3 W PTC (91.4% retention) across Flextronics FXS-275BB-SAC1B's 1.641 m2 aperture.

Who should skip Flextronics FXS-275BB-SAC1B on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 Flextronics FXS-275BB-SAC1B panels (530 sq ft) leave unusable roof gaps vs. AXITEC AC-275P/60S.

What is the 1,000 V commercial string limit for Flextronics FXS-275BB-SAC1B?

On 1,000 V commercial inverters at -10 C (42.92 V cold Voc), Flextronics FXS-275BB-SAC1B fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Flextronics FXS-275BB-SAC1B.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.