Skip to main content
WireAndSun
Calculators
CEC PV Module

GCL System Integration Technology Co Ltd GCL-P6/60275 — CEC Solar Module Specifications

Manufacturer: GCL System Integration Technology Co Ltd Registry: CEC Verified Engineering Specification

GCL System Integration Technology Co Ltd GCL-P6/60275 is a 275.0 W STC (249.3 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.9% efficiency, 38.5 V Voc at 25 C, and 42.79 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
249.3 W
Voc @ 25C
38.5 V
Efficiency
16.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GCL System Integration Technology Co Ltd GCL-P6/60275 Compare Against Peer CEC Listings?

How GCL System Integration Technology Co Ltd GCL System Integration Technology Co Ltd GCL-P6/60275 handles rooftop heat (249.3 W PTC), 8 kW sizing, and cold winter string voltage.

GCL System Integration Technology Co Ltd builds the GCL System Integration Technology Co Ltd GCL-P6/60275 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 169.0 W/m2 (3.01 percentage points below 19.91% CEC median). Compared against AXITEC AC-275P/60S (275.0 W), this model holds typical 90.7% PTC-to-STC thermal output (249.3 W real-world rating). Lower 38.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.63 A overcurrent floor served by a 15 A breaker.

Where Does GCL System Integration Technology Co Ltd GCL-P6/60275 Fall Across Listed CEC Models?

Where GCL System Integration Technology Co Ltd GCL-P6/60275 (275.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where GCL System Integration Technology Co Ltd GCL-P6/60275 (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGCL System Integra: 275.0 W

What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-P6/60275?

Percentile placement of GCL System Integration Technology Co Ltd GCL-P6/60275 across power density (169.0 W/m2), thermal retention, and nameplate STC wattage.

GCL System Integration Technology Co Ltd GCL-P6/60275 Engineering BenchmarksPercentile comparison of GCL System Integration Technology Co Ltd GCL-P6/60275 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention90.7%Module Efficiency16.9%

What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-P6/60275?

Four critical engineering numbers homeowners and solar installers check first when reviewing GCL System Integration Technology Co Ltd GCL-P6/60275 specifications.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,623

16.9% Aperture Efficiency

Power density 169.0 W/m2 (3.01 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.79 V at -10 C (599.1 V string) and 44.01 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 48.8 m2 (525 sq ft) producing 7,479 W PTC; NEC 690.8 OCPD floor is 14.63 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.5 * (1 + (-0.318/100) * (-10 - 25)) = 42.79 V | OCPD = 1.56 * 9.38 = 14.63 A

Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-P6/60275: Voc=38.5 V, beta_Voc=-0.318%/C, Isc=9.38 A, STC=275.0 W, Area=1.627 m2.

Result: 14 panels max on 600 V (599.1 V); 30 panels for 8 kW (525 sq ft).

What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-P6/60275?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GCL System Integration Technology Co Ltd GCL-P6/60275.

Official California Energy Commission (NREL SAM) test parameters for GCL System Integration Technology Co Ltd GCL-P6/60275.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 249.3 W (90.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.38 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.2 V / 8.7 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.318 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.9% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many GCL System Integration Technology Co Ltd GCL-P6/60275 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GCL System Integration Technology Co Ltd GCL-P6/60275 (275.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 385 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 525 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 648 sq ft $2,548 $4,308

How Many GCL System Integration Technology Co Ltd GCL-P6/60275 Modules Fit in a Cold-Weather String?

Maximum series module counts for GCL System Integration Technology Co Ltd GCL-P6/60275 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.5V and beta_Voc=-0.318%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.01 V 13 panels 572.1 V 22 panels
-10 C (14 F) 42.79 V 14 panels 599.1 V 23 panels
0 C (32 F) 41.56 V 14 panels 581.8 V 24 panels
25 C (77 F STC) 38.5 V 15 panels 577.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-P6/60275?

Alternative CEC solar modules from competing brands near GCL System Integration Technology Co Ltd GCL-P6/60275 (275.0 W), including AXITEC AC-275P/60S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-275P/60S
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
AXITEC AC-275P/60V
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
Flextronics FXS-275BB-SAC1B
Flextronics
275.0 W Tie (0 W) 38.6 V 16.75% 91.4%
Anhui Rinengzhongtian Semiconductor Development QJP275-60
Anhui Rinengzhongtian Semiconductor Development
275.0 W Tie (0 W) 38.01 V 16.9% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-P6/60275?

Evaluate GCL System Integration Technology Co Ltd GCL-P6/60275 (275.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-P6/60275 reaches 44.01 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 525 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (525 sq ft).
  • 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-P6/60275 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

GCL System Integration Technology Co Ltd GCL-P6/60275 8 kW Residential Fit

Needs 30 modules (525 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-275P/60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 249.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GCL System Integration Technology Co Ltd GCL-P6/60275 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for GCL System Integration Technology Co Ltd GCL-P6/60275?

Multiplying GCL System Integration Technology Co Ltd GCL-P6/60275's 9.38 A short-circuit current by 1.56 equals 14.63 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can GCL System Integration Technology Co Ltd GCL-P6/60275 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.79 V cold Voc at 14 F and handles 9.38 A Isc; string inverters cap GCL System Integration Technology Co Ltd GCL-P6/60275 at 14 panels on 600 V.

Is GCL System Integration Technology Co Ltd GCL-P6/60275 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GCL System Integration Technology Co Ltd GCL-P6/60275 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.