Anhui Rinengzhongtian Semiconductor Development QJP275-60 is a 275.0 W STC (249.7 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.9% efficiency, 38.01 V Voc at 25 C, and 42.4 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 249.7 W
- Voc @ 25C
- 38.01 V
- Efficiency
- 16.9%
How Does Anhui Rinengzhongtian Semiconductor Development QJP275-60 Compare Against Peer CEC Listings?
Engineering position of Anhui Rinengzhongtian Semiconductor Development QJP275-60 (275.0 W STC) vs. Chinaland Solar Energy HSE275-60M-B across 1,407 CEC Multi-c-Si solar modules.
Built with 60 Multi-c-Si cells, Anhui Rinengzhongtian Semiconductor Development QJP275-60 pairs typical 90.8% PTC-to-STC thermal output (249.7 W real-world rating) with 38.01 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,491 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Chinaland Solar Energy HSE275-60M-B offers a 275.0 W alternative.
Where Does Anhui Rinengzhongtian Semiconductor Development QJP275-60 Fall Across Listed CEC Models?
Plots Anhui Rinengzhongtian Semiconductor Development QJP275-60 at 275.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Anhui Rinengzhongtian Semiconductor Development QJP275-60?
Benchmarks Anhui Rinengzhongtian Semiconductor Development QJP275-60 on STC wattage, thermal PTC/STC retention, and 16.9 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Anhui Rinengzhongtian Semiconductor Development QJP275-60?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Anhui Rinengzhongtian Semiconductor Development QJP275-60 by Anhui Rinengzhongtian Semiconductor Development.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.9% Aperture Efficiency
Power density 169.0 W/m2 (3.01 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.4 V at -10 C (593.6 V string) and 43.65 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 48.8 m2 (525 sq ft) producing 7,491 W PTC; NEC 690.8 OCPD floor is 14.85 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.01 * (1 + (-0.33/100) * (-10 - 25)) = 42.4 V | OCPD = 1.56 * 9.52 = 14.85 A
Inputs from CEC Modules.csv for Anhui Rinengzhongtian Semiconductor Development QJP275-60: Voc=38.01 V, beta_Voc=-0.33%/C, Isc=9.52 A, STC=275.0 W, Area=1.627 m2.
Result: 14 panels max on 600 V (593.6 V); 30 panels for 8 kW (525 sq ft).
What Are the Published CEC Specifications for Anhui Rinengzhongtian Semiconductor Development QJP275-60?
Laboratory test ratings recorded for Anhui Rinengzhongtian Semiconductor Development QJP275-60 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 249.7 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.01 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.52 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.9 V / 8.9 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.9% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Anhui Rinengzhongtian Semiconductor Development QJP275-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (525 sq ft at 8 kW), and estimated Year-1 electric bill offset for Anhui Rinengzhongtian Semiconductor Development QJP275-60.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 385 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 525 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 648 sq ft | $2,548 | $4,308 |
How Many Anhui Rinengzhongtian Semiconductor Development QJP275-60 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Anhui Rinengzhongtian Semiconductor Development QJP275-60 (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.65 V | 13 panels | 567.4 V | 22 panels |
| -10 C (14 F) | 42.4 V | 14 panels | 593.6 V | 23 panels |
| 0 C (32 F) | 41.15 V | 14 panels | 576.1 V | 24 panels |
| 25 C (77 F STC) | 38.01 V | 15 panels | 570.1 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Anhui Rinengzhongtian Semiconductor Development QJP275-60?
Closest cross-brand CEC competitors to Anhui Rinengzhongtian Semiconductor Development QJP275-60 matched near 275.0 W STC and 38.01 V Voc, led by Chinaland Solar Energy HSE275-60M-B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE275-60M-B Chinaland Solar Energy |
275.0 W | Tie (0 W) | 38.0 V | 16.09% | 90.5% |
| CSI Solar Co Ltd CS6P-275P CSI Solar Co Ltd |
275.0 W | Tie (0 W) | 38.0 V | 17.26% | 91.6% |
| AXITEC AC-275P/60S AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| AXITEC AC-275P/60V AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
What Are the Design Limits and Best-Fit Uses for Anhui Rinengzhongtian Semiconductor Development QJP275-60?
Evaluate Anhui Rinengzhongtian Semiconductor Development QJP275-60 (275.0 W STC, 38.01 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Anhui Rinengzhongtian Semiconductor Development QJP275-60 reaches 43.65 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 525 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (525 sq ft).
- 2026 tax credit baseline: cash residential installs of Anhui Rinengzhongtian Semiconductor Development QJP275-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Anhui Rinengzhongtian Semiconductor Development QJP275-60 8 kW Residential Fit
Needs 30 modules (525 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Chinaland Solar Energy HSE275-60M-B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 249.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Anhui Rinengzhongtian Semiconductor Development QJP275-60 by Anhui Rinengzhongtian Semiconductor Development grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Anhui Rinengzhongtian Semiconductor Development QJP275-60?
Multiplying Anhui Rinengzhongtian Semiconductor Development QJP275-60's 9.52 A short-circuit current by 1.56 equals 14.85 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Anhui Rinengzhongtian Semiconductor Development QJP275-60 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.4 V cold Voc at 14 F and handles 9.52 A Isc; string inverters cap Anhui Rinengzhongtian Semiconductor Development QJP275-60 at 14 panels on 600 V.
Is Anhui Rinengzhongtian Semiconductor Development QJP275-60 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Anhui Rinengzhongtian Semiconductor Development QJP275-60 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.