Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS6P-275P — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS6P-275P is a 275.0 W STC (251.8 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 17.26% efficiency, 38.0 V Voc at 25 C, and 42.08 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
251.8 W
Voc @ 25C
38.0 V
Efficiency
17.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS6P-275P Compare Against Peer CEC Listings?

How CSI Solar Co Ltd CSI Solar Co Ltd CS6P-275P handles rooftop heat (251.8 W PTC), 8 kW sizing, and cold winter string voltage.

CSI Solar Co Ltd builds the CSI Solar Co Ltd CS6P-275P (Multi-c-Si) as a compact residential or specialty off-grid module delivering 172.6 W/m2 (2.65 percentage points below 19.91% CEC median). Compared against Chinaland Solar Energy HSE275-60M-B (275.0 W), this model holds strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677). Lower 38.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.74 A overcurrent floor served by a 15 A breaker.

Where Does CSI Solar Co Ltd CS6P-275P Fall Across Listed CEC Models?

Where CSI Solar Co Ltd CS6P-275P (275.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS6P-275P (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 275.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS6P-275P?

Percentile placement of CSI Solar Co Ltd CS6P-275P across power density (172.6 W/m2), thermal retention, and nameplate STC wattage.

CSI Solar Co Ltd CS6P-275P Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS6P-275P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention91.6%Module Efficiency17.26%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS6P-275P?

Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS6P-275P specifications.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,118

17.26% Aperture Efficiency

Power density 172.6 W/m2 (2.65 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.08 V at -10 C (589.1 V string) and 43.25 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 47.8 m2 (514 sq ft) producing 7,554 W PTC; NEC 690.8 OCPD floor is 14.74 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.0 * (1 + (-0.307/100) * (-10 - 25)) = 42.08 V | OCPD = 1.56 * 9.45 = 14.74 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS6P-275P: Voc=38.0 V, beta_Voc=-0.307%/C, Isc=9.45 A, STC=275.0 W, Area=1.593 m2.

Result: 14 panels max on 600 V (589.1 V); 30 panels for 8 kW (514 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS6P-275P?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS6P-275P.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS6P-275P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 251.8 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.0 V / 8.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.26% (1.593 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many CSI Solar Co Ltd CS6P-275P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS6P-275P (275.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 377 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 514 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 634 sq ft $2,548 $4,308

How Many CSI Solar Co Ltd CS6P-275P Modules Fit in a Cold-Weather String?

Maximum series module counts for CSI Solar Co Ltd CS6P-275P from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.0V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.25 V 13 panels 562.2 V 23 panels
-10 C (14 F) 42.08 V 14 panels 589.1 V 23 panels
0 C (32 F) 40.92 V 14 panels 572.9 V 24 panels
25 C (77 F STC) 38.0 V 15 panels 570.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS6P-275P?

Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS6P-275P (275.0 W), including Chinaland Solar Energy HSE275-60M-B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Chinaland Solar Energy HSE275-60M-B
Chinaland Solar Energy
275.0 W Tie (0 W) 38.0 V 16.09% 90.5%
Anhui Rinengzhongtian Semiconductor Development QJP275-60
Anhui Rinengzhongtian Semiconductor Development
275.0 W Tie (0 W) 38.01 V 16.9% 90.8%
Anhui Rinengzhongtian Semiconductor Development QJM275-60
Anhui Rinengzhongtian Semiconductor Development
275.0 W Tie (0 W) 37.88 V 16.9% 90.4%
AXITEC AC-275P/60S
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS6P-275P?

Evaluate CSI Solar Co Ltd CS6P-275P (275.0 W STC, 38.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS6P-275P reaches 43.25 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 514 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (514 sq ft).
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS6P-275P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS6P-275P 8 kW Residential Fit

Needs 30 modules (514 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Chinaland Solar Energy HSE275-60M-B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 251.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS6P-275P by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS6P-275P?

Multiplying CSI Solar Co Ltd CS6P-275P's 9.45 A short-circuit current by 1.56 equals 14.74 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can CSI Solar Co Ltd CS6P-275P pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.08 V cold Voc at 14 F and handles 9.45 A Isc; string inverters cap CSI Solar Co Ltd CS6P-275P at 14 panels on 600 V.

Is CSI Solar Co Ltd CS6P-275P eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS6P-275P rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.