AXITEC AC-275P/60V is a 275.0 W STC (253.6 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.87% efficiency, 38.5 V Voc at 25 C, and 42.53 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 253.6 W
- Voc @ 25C
- 38.5 V
- Efficiency
- 16.87%
How Does AXITEC AC-275P/60V Compare Against Peer CEC Listings?
Solar engineering breakdown for AXITEC AC-275P/60V: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Measured at 275.0 W STC and 253.6 W PTC, AXITEC AC-275P/60V sits -110.0 W vs all-CEC median (below all-CEC median; higher than 14.3% of peers) among 21,677 listed modules. Power density reaches 168.7 W/m2 (3.04 percentage points below 19.91% CEC median). Lower 38.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-M6/60275 rates 275.0 W.
Where Does AXITEC AC-275P/60V Fall Across Listed CEC Models?
Distribution marker showing AXITEC AC-275P/60V (275.0 W) relative to the 385.0 W all-CEC solar panel median. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Dataset Percentiles Define AXITEC AC-275P/60V?
Dataset percentiles tracking AXITEC AC-275P/60V power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for AXITEC AC-275P/60V?
Benchmark highlights for AXITEC AC-275P/60V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.87% Aperture Efficiency
Power density 168.7 W/m2 (3.04 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.53 V at -10 C (595.4 V string) and 43.68 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 48.9 m2 (526 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 14.41 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.5 * (1 + (-0.299/100) * (-10 - 25)) = 42.53 V | OCPD = 1.56 * 9.24 = 14.41 A
Inputs from CEC Modules.csv for AXITEC AC-275P/60V: Voc=38.5 V, beta_Voc=-0.299%/C, Isc=9.24 A, STC=275.0 W, Area=1.63 m2.
Result: 14 panels max on 600 V (595.4 V); 30 panels for 8 kW (526 sq ft).
What Are the Published CEC Specifications for AXITEC AC-275P/60V?
Official CEC datasheet figures for AXITEC AC-275P/60V (Multi-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 253.6 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.46 V / 8.74 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.299 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.87% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many AXITEC AC-275P/60V Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AXITEC AC-275P/60V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 386 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 526 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 649 sq ft | $2,548 | $4,308 |
How Many AXITEC AC-275P/60V Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-275P/60V (42.53 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.68 V | 13 panels | 567.8 V | 22 panels |
| -10 C (14 F) | 42.53 V | 14 panels | 595.4 V | 23 panels |
| 0 C (32 F) | 41.38 V | 14 panels | 579.3 V | 24 panels |
| 25 C (77 F STC) | 38.5 V | 15 panels | 577.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-275P/60V?
Competing CEC solar panels closest to AXITEC AC-275P/60V in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60275.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 90.0% |
| GCL System Integration Technology Co Ltd GCL-P6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.9% | 90.7% |
| Flextronics FXS-275BB-SAC1B Flextronics |
275.0 W | Tie (0 W) | 38.6 V | 16.75% | 91.4% |
| Anhui Rinengzhongtian Semiconductor Development QJP275-60 Anhui Rinengzhongtian Semiconductor Development |
275.0 W | Tie (0 W) | 38.01 V | 16.9% | 90.8% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-275P/60V?
Evaluate AXITEC AC-275P/60V (275.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-275P/60V reaches 43.68 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 526 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (526 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-275P/60V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-275P/60V 8 kW Residential Fit
Needs 30 modules (526 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60275.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 253.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-275P/60V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-275P/60V panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-275P/60V cold Voc rises from 38.5 V to 42.53 V (beta_Voc -0.299%/C), capping a 600 V string at 14 panels (595.4 V).
How much roof area does an 8 kW array of AXITEC AC-275P/60V need?
An 8 kW DC system uses 30 AXITEC AC-275P/60V modules (8,250 W STC / 7,608 W PTC), covering roughly 526 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does AXITEC AC-275P/60V compare against GCL System Integration Technology Co Ltd GCL-M6/60275?
AXITEC AC-275P/60V outputs 275.0 W STC (38.5 V Voc, rank #18,259 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/60275 delivers 275.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)