US Solar USS-QCMO3-60-240 is a 240.0 W STC (217.4 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.64% efficiency, 36.8 V Voc at 25 C, and 40.97 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 217.4 W
- Voc @ 25C
- 36.8 V
- Efficiency
- 14.64%
How Does US Solar USS-QCMO3-60-240 Compare Against Peer CEC Listings?
Engineering position of US Solar USS-QCMO3-60-240 (240.0 W STC) vs. Centrosolar America DM60 240 across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, US Solar USS-QCMO3-60-240 pairs typical 90.6% PTC-to-STC thermal output (217.4 W real-world rating) with 36.8 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,392 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM60 240 offers a 240.0 W alternative.
Where Does US Solar USS-QCMO3-60-240 Fall Across Listed CEC Models?
Plots US Solar USS-QCMO3-60-240 at 240.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define US Solar USS-QCMO3-60-240?
Benchmarks US Solar USS-QCMO3-60-240 on STC wattage, thermal PTC/STC retention, and 14.64 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for US Solar USS-QCMO3-60-240?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for US Solar USS-QCMO3-60-240 by US Solar.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.64% Aperture Efficiency
Power density 146.3 W/m2 (5.27 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.97 V at -10 C (573.6 V string) and 42.17 V at -20 C (14 max).
34 Panels = 8,160 W STC
Occupies 55.8 m2 (600 sq ft) producing 7,392 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.8 * (1 + (-0.324/100) * (-10 - 25)) = 40.97 V | OCPD = 1.56 * 8.6 = 13.42 A
Inputs from CEC Modules.csv for US Solar USS-QCMO3-60-240: Voc=36.8 V, beta_Voc=-0.324%/C, Isc=8.6 A, STC=240.0 W, Area=1.64 m2.
Result: 14 panels max on 600 V (573.6 V); 34 panels for 8 kW (600 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMO3-60-240?
Laboratory test ratings recorded for US Solar USS-QCMO3-60-240 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 217.4 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.7 V / 8.1 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.64% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMO3-60-240 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (600 sq ft at 8 kW), and estimated Year-1 electric bill offset for US Solar USS-QCMO3-60-240.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 441 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 600 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 741 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Sibling wattage bins and frame colors grouped with US Solar USS-QCMO3-60-240 under US Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMO3-60-230 | 230.0 W | 208.1 W | 36.2 V | 28.8 V | 14.03% |
| US Solar USS-QCMO3-60-235 | 235.0 W | 212.8 W | 36.5 V | 29.4 V | 14.33% |
| US Solar USS-QCMO3-60-240 | 240.0 W | 217.4 W | 36.8 V | 29.7 V | 14.64% |
| US Solar USS-QCMO3-60-245 | 245.0 W | 222.0 W | 37.1 V | 30.3 V | 14.94% |
How Many US Solar USS-QCMO3-60-240 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for US Solar USS-QCMO3-60-240 (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.17 V | 14 panels | 590.4 V | 23 panels |
| -10 C (14 F) | 40.97 V | 14 panels | 573.6 V | 24 panels |
| 0 C (32 F) | 39.78 V | 15 panels | 596.7 V | 25 panels |
| 25 C (77 F STC) | 36.8 V | 16 panels | 588.8 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMO3-60-240?
Closest cross-brand CEC competitors to US Solar USS-QCMO3-60-240 matched near 240.0 W STC and 36.8 V Voc, led by Centrosolar America DM60 240.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DM60 240 Centrosolar America |
240.0 W | Tie (0 W) | 36.8 V | 14.64% | 90.6% |
| Heliene 60M240 Heliene |
240.0 W | Tie (0 W) | 36.8 V | 14.43% | 90.1% |
| Eoplly New Energy Technology EP156M/60-240S AC Eoplly New Energy Technology |
240.0 W | Tie (0 W) | 36.9 V | 14.83% | 89.7% |
| Eoplly New Energy Technology EP156MB/60-240S AC Eoplly New Energy Technology |
240.0 W | Tie (0 W) | 36.9 V | 14.83% | 89.5% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMO3-60-240?
Evaluate US Solar USS-QCMO3-60-240 (240.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMO3-60-240 reaches 42.17 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 600 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (600 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMO3-60-240 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMO3-60-240 8 kW Residential Fit
Needs 34 modules (600 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DM60 240.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 217.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMO3-60-240 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMO3-60-240?
Multiplying US Solar USS-QCMO3-60-240's 8.6 A short-circuit current by 1.56 equals 13.42 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can US Solar USS-QCMO3-60-240 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.97 V cold Voc at 14 F and handles 8.6 A Isc; string inverters cap US Solar USS-QCMO3-60-240 at 14 panels on 600 V.
Is US Solar USS-QCMO3-60-240 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMO3-60-240 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)