Skip to main content
WireAndSun
Calculators
CEC PV Module

Sunflare Co FLEX60-180W-M20-A — CEC Solar Module Specifications

Manufacturer: Sunflare Co Registry: CEC Verified Engineering Specification

Sunflare Co FLEX60-180W-M20-A is a 180.0 W STC (156.2 W PTC) Thin Film solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 10.98% efficiency, 36.4 V Voc at 25 C, and 40.39 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
180.0 W
PTC Wattage
156.2 W
Voc @ 25C
36.4 V
Efficiency
10.98%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sunflare Co FLEX60-180W-M20-A Compare Against Peer CEC Listings?

Engineering position of Sunflare Co FLEX60-180W-M20-A (180.0 W STC) vs. WAAREE ENERGIES LIMITED WU-180 across 106 CEC Thin Film solar modules.

Ranking #21,232 across 21,677 CEC solar panels (below all-CEC median; higher than 1.8% of peers), Sunflare Co FLEX60-180W-M20-A operates as a compact residential or specialty off-grid module sitting 62.5 W above the 117.5 W Thin Film median. Lower 36.4 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 86.8% PTC-to-STC thermal output (156.2 W real-world rating), 45 panels occupy 794 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Sunflare Co FLEX60-180W-M20-A Fall Across Listed CEC Models?

Plots Sunflare Co FLEX60-180W-M20-A at 180.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sunflare Co FLEX60-180W-M20-A (180.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunflare Co FLEX60: 180.0 W

What Dataset Percentiles Define Sunflare Co FLEX60-180W-M20-A?

Benchmarks Sunflare Co FLEX60-180W-M20-A on STC wattage, thermal PTC/STC retention, and 10.98 aperture conversion efficiency against CEC peers.

Sunflare Co FLEX60-180W-M20-A Engineering BenchmarksPercentile comparison of Sunflare Co FLEX60-180W-M20-A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage180.0 WPTC/STC Retention86.8%Module Efficiency10.98%

What Do the Dataset Ranks Show for Sunflare Co FLEX60-180W-M20-A?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Sunflare Co FLEX60-180W-M20-A by Sunflare Co.

Rank #21,232 / 21,677

180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,599

10.98% Aperture Efficiency

Power density 109.8 W/m2 (8.93 percentage points below 19.91% CEC median). PTC/STC ratio: 86.8% (rank #21,603).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.39 V at -10 C (565.5 V string) and 41.53 V at -20 C (14 max).

8 kW Reference Array

45 Panels = 8,100 W STC

Occupies 73.8 m2 (794 sq ft) producing 7,029 W PTC; NEC 690.8 OCPD floor is 11.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.4 * (1 + (-0.313/100) * (-10 - 25)) = 40.39 V | OCPD = 1.56 * 7.43 = 11.59 A

Inputs from CEC Modules.csv for Sunflare Co FLEX60-180W-M20-A: Voc=36.4 V, beta_Voc=-0.313%/C, Isc=7.43 A, STC=180.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (565.5 V); 45 panels for 8 kW (794 sq ft).

What Are the Published CEC Specifications for Sunflare Co FLEX60-180W-M20-A?

Laboratory test ratings recorded for Sunflare Co FLEX60-180W-M20-A (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Sunflare Co FLEX60-180W-M20-A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 180.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 156.2 W (86.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 28.68 V / 6.28 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.313 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 10.98% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Thin Film) Monofacial backsheet

How Many Sunflare Co FLEX60-180W-M20-A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (794 sq ft at 8 kW), and estimated Year-1 electric bill offset for Sunflare Co FLEX60-180W-M20-A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 34 6.12 kW 600 sq ft $1,532 $2,590
8 kW Class 45 8.1 kW 794 sq ft $2,027 $3,428
10 kW Class 56 10.08 kW 989 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Sunflare Co Series?

Sibling wattage bins and frame colors grouped with Sunflare Co FLEX60-180W-M20-A under Sunflare Co to prevent duplicate spec pages.

Sibling CEC listings grouped into the Sunflare Co FLEX60-180W-M20-A wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Sunflare Co FLEX60-175W-M20-A 175.0 W 151.7 W 35.95 V 28.18 V 10.67%
Sunflare Co FLEX60-180W-M20-A 180.0 W 156.2 W 36.4 V 28.68 V 10.98%
Sunflare Co FLEX60-185W-M20-A 185.0 W 160.6 W 36.63 V 28.33 V 11.28%

How Many Sunflare Co FLEX60-180W-M20-A Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Sunflare Co FLEX60-180W-M20-A (beta_Voc -0.313%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.4V and beta_Voc=-0.313%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.53 V 14 panels 581.4 V 24 panels
-10 C (14 F) 40.39 V 14 panels 565.5 V 24 panels
0 C (32 F) 39.25 V 15 panels 588.8 V 25 panels
25 C (77 F STC) 36.4 V 16 panels 582.4 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Sunflare Co FLEX60-180W-M20-A?

Closest cross-brand CEC competitors to Sunflare Co FLEX60-180W-M20-A matched near 180.0 W STC and 36.4 V Voc, led by WAAREE ENERGIES LIMITED WU-180.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
WAAREE ENERGIES LIMITED WU-180
WAAREE ENERGIES LIMITED
180.0 W Tie (0 W) 32.0 V 12.2% 88.7%
Solartech Power SPM195P
Solartech Power
195.0 W +15.0 W 35.6 V 11.96% 83.8%
Hanwha Qcells (Qidong) Co Ltd SF190-27-P185
Hanwha Qcells (Qidong) Co Ltd
185.0 W +5.0 W 32.5 V 12.38% 88.6%
Mitsubishi Electric PV-MF180UD4
Mitsubishi Electric
180.0 W Tie (0 W) 30.4 V 13.0% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sunflare Co FLEX60-180W-M20-A?

Evaluate Sunflare Co FLEX60-180W-M20-A (180.0 W STC, 36.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sunflare Co FLEX60-180W-M20-A reaches 41.53 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 45 panels for an 8 kW build require 794 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (794 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sunflare Co FLEX60-180W-M20-A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sunflare Co FLEX60-180W-M20-A 8 kW Residential Fit

Needs 45 modules (794 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare WAAREE ENERGIES LIMITED WU-180.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 156.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunflare Co FLEX60-180W-M20-A by Sunflare Co grounded in CEC test data and NEC 690.7/690.8 limits.

How many Sunflare Co FLEX60-180W-M20-A panels fit on a 600 V winter solar string?

At -10 C (14 F), Sunflare Co FLEX60-180W-M20-A cold Voc rises from 36.4 V to 40.39 V (beta_Voc -0.313%/C), capping a 600 V string at 14 panels (565.5 V).

How much roof area does an 8 kW array of Sunflare Co FLEX60-180W-M20-A need?

An 8 kW DC system uses 45 Sunflare Co FLEX60-180W-M20-A modules (8,100 W STC / 7,029 W PTC), covering roughly 794 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Sunflare Co FLEX60-180W-M20-A compare against WAAREE ENERGIES LIMITED WU-180?

Sunflare Co FLEX60-180W-M20-A outputs 180.0 W STC (36.4 V Voc, rank #21,232 of 21,677), while WAAREE ENERGIES LIMITED WU-180 delivers 180.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.