Skip to main content
WireAndSun
Calculators
CEC PV Module

Solartech Power SPM195P — CEC Solar Module Specifications

Manufacturer: Solartech Power Registry: CEC Verified Engineering Specification

Solartech Power SPM195P is a 195.0 W STC (163.5 W PTC) Multi-c-Si solar module ranking #21,088 of 21,677 CEC listings (below all-CEC median; higher than 2.5% of peers). It delivers 11.96% efficiency, 35.6 V Voc at 25 C, and 40.14 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
195.0 W
PTC Wattage
163.5 W
Voc @ 25C
35.6 V
Efficiency
11.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solartech Power SPM195P Compare Against Peer CEC Listings?

Solar engineering breakdown for Solartech Power SPM195P: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Measured at 195.0 W STC and 163.5 W PTC, Solartech Power SPM195P sits -190.0 W vs all-CEC median (below all-CEC median; higher than 2.5% of peers) among 21,677 listed modules. Power density reaches 119.6 W/m2 (7.95 percentage points below 19.91% CEC median). Lower 35.6 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Yingli Energy (China) YL195P-26b rates 195.0 W.

Where Does Solartech Power SPM195P Fall Across Listed CEC Models?

Distribution marker showing Solartech Power SPM195P (195.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solartech Power SPM195P (195.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolartech Power SP: 195.0 W

What Dataset Percentiles Define Solartech Power SPM195P?

Dataset percentiles tracking Solartech Power SPM195P power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Solartech Power SPM195P Engineering BenchmarksPercentile comparison of Solartech Power SPM195P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage195.0 WPTC/STC Retention83.8%Module Efficiency11.96%

What Do the Dataset Ranks Show for Solartech Power SPM195P?

Benchmark highlights for Solartech Power SPM195P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #21,088 / 21,677

195.0 W STC · Higher Than 2.5%

195.0 W STC (-190.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,576

11.96% Aperture Efficiency

Power density 119.6 W/m2 (7.95 percentage points below 19.91% CEC median). PTC/STC ratio: 83.8% (rank #21,673).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.14 V at -10 C (562.0 V string) and 41.43 V at -20 C (14 max).

8 kW Reference Array

42 Panels = 8,190 W STC

Occupies 68.5 m2 (737 sq ft) producing 6,867 W PTC; NEC 690.8 OCPD floor is 11.86 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.6 * (1 + (-0.364/100) * (-10 - 25)) = 40.14 V | OCPD = 1.56 * 7.6 = 11.86 A

Inputs from CEC Modules.csv for Solartech Power SPM195P: Voc=35.6 V, beta_Voc=-0.364%/C, Isc=7.6 A, STC=195.0 W, Area=1.63 m2.

Result: 14 panels max on 600 V (562.0 V); 42 panels for 8 kW (737 sq ft).

What Are the Published CEC Specifications for Solartech Power SPM195P?

Official CEC datasheet figures for Solartech Power SPM195P (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Solartech Power SPM195P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 195.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 163.5 W (83.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 28.5 V / 6.85 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.364 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 11.96% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Solartech Power SPM195P Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solartech Power SPM195P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 31 6.04 kW 544 sq ft $1,512 $2,556
8 kW Class 42 8.19 kW 737 sq ft $2,050 $3,466
10 kW Class 52 10.14 kW 912 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Solartech Power Series?

Consolidated Solartech Power wattage variants sharing the Solartech Power SPM195P mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Solartech Power SPM195P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solartech Power SPM190P 190.0 W 159.1 W 35.6 V 28.5 V 11.66%
Solartech Power SPM195P 195.0 W 163.5 W 35.6 V 28.5 V 11.96%

How Many Solartech Power SPM195P Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solartech Power SPM195P (40.14 V at 14 F).

Computed from Voc=35.6V and beta_Voc=-0.364%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.43 V 14 panels 580.0 V 24 panels
-10 C (14 F) 40.14 V 14 panels 562.0 V 24 panels
0 C (32 F) 38.84 V 15 panels 582.6 V 25 panels
25 C (77 F STC) 35.6 V 16 panels 569.6 V 28 panels

Which Cross-Brand Solar Modules Compare Closest to Solartech Power SPM195P?

Competing CEC solar panels closest to Solartech Power SPM195P in nameplate wattage and Voc, starting with Yingli Energy (China) YL195P-26b.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Yingli Energy (China) YL195P-26b
Yingli Energy (China)
195.0 W Tie (0 W) 33.6 V 13.31% 88.7%
APOS Energy AP195
APOS Energy
195.0 W Tie (0 W) 33.11 V 13.0% 88.8%
Gintung Energy ASEC-195G6S
Gintung Energy
195.0 W Tie (0 W) 32.95 V 13.86% 89.4%
Gintung Energy ASEC-195G6M
Gintung Energy
195.0 W Tie (0 W) 32.94 V 13.86% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solartech Power SPM195P?

Evaluate Solartech Power SPM195P (195.0 W STC, 35.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solartech Power SPM195P reaches 41.43 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 42 panels for an 8 kW build require 737 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 42 panels (737 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solartech Power SPM195P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solartech Power SPM195P 8 kW Residential Fit

Needs 42 modules (737 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Yingli Energy (China) YL195P-26b.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 163.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Power SPM195P by Solartech Power grounded in CEC test data and NEC 690.7/690.8 limits.

How many Solartech Power SPM195P panels fit on a 600 V winter solar string?

At -10 C (14 F), Solartech Power SPM195P cold Voc rises from 35.6 V to 40.14 V (beta_Voc -0.364%/C), capping a 600 V string at 14 panels (562.0 V).

How much roof area does an 8 kW array of Solartech Power SPM195P need?

An 8 kW DC system uses 42 Solartech Power SPM195P modules (8,190 W STC / 6,867 W PTC), covering roughly 737 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Solartech Power SPM195P compare against Yingli Energy (China) YL195P-26b?

Solartech Power SPM195P outputs 195.0 W STC (35.6 V Voc, rank #21,088 of 21,677), while Yingli Energy (China) YL195P-26b delivers 195.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.