Solartech Power SPM235P — CEC Solar Module Specifications

Manufacturer: Solartech Power Registry: CEC Verified Engineering Specification

Solartech Power SPM235P is a 235.0 W STC (210.0 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.6% efficiency, 37.26 V Voc at 25 C, and 41.89 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
210.0 W
Voc @ 25C
37.26 V
Efficiency
14.6%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solartech Power SPM235P Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Solartech Power SPM235P (Multi-c-Si) residential solar systems.

Solartech Power SPM235P delivers 146.0 W/m2 (5.31 percentage points below 19.91% CEC median) and typical 89.4% PTC-to-STC thermal output (210.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (607 sq ft). At -4 F (-20 C), string voltage climbs to 43.21 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Gintech Energy GTE 235M (235.0 W).

Where Does Solartech Power SPM235P Fall Across Listed CEC Models?

Comparison of Solartech Power SPM235P (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solartech Power SPM235P (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolartech Power SP: 235.0 W

What Dataset Percentiles Define Solartech Power SPM235P?

Relative ranking of Solartech Power SPM235P across nameplate watts, 89.4% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Solartech Power SPM235P Engineering BenchmarksPercentile comparison of Solartech Power SPM235P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention89.4%Module Efficiency14.6%

What Do the Dataset Ranks Show for Solartech Power SPM235P?

Summary of Solartech Power SPM235P output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,290

14.6% Aperture Efficiency

Power density 146.0 W/m2 (5.31 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.89 V at -10 C (586.5 V string) and 43.21 V at -20 C (13 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 56.4 m2 (607 sq ft) producing 7,350 W PTC; NEC 690.8 OCPD floor is 13.18 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.26 * (1 + (-0.355/100) * (-10 - 25)) = 41.89 V | OCPD = 1.56 * 8.45 = 13.18 A

Inputs from CEC Modules.csv for Solartech Power SPM235P: Voc=37.26 V, beta_Voc=-0.355%/C, Isc=8.45 A, STC=235.0 W, Area=1.61 m2.

Result: 14 panels max on 600 V (586.5 V); 35 panels for 8 kW (607 sq ft).

What Are the Published CEC Specifications for Solartech Power SPM235P?

Complete CEC test sheet for Solartech Power SPM235P including Isc (8.45 A), Voc (37.26 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Solartech Power SPM235P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 210.0 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.63 V / 7.93 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.355 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.6% (1.61 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Solartech Power SPM235P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Solartech Power SPM235P.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 451 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 607 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 745 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Solartech Power Series?

Related Solartech Power power steps and black/silver trims consolidated into this Solartech Power SPM235P series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Solartech Power SPM235P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solartech Power SPM225P 225.0 W 200.8 W 37.08 V 29.34 V 13.98%
Solartech Power SPM230P 230.0 W 205.4 W 37.2 V 29.49 V 14.29%
Solartech Power SPM235P 235.0 W 210.0 W 37.26 V 29.63 V 14.6%
Solartech Power SPM240P 240.0 W 214.6 W 37.38 V 29.77 V 14.91%

How Many Solartech Power SPM235P Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Solartech Power SPM235P (37.26 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.26V and beta_Voc=-0.355%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.21 V 13 panels 561.7 V 23 panels
-10 C (14 F) 41.89 V 14 panels 586.5 V 23 panels
0 C (32 F) 40.57 V 14 panels 568.0 V 24 panels
25 C (77 F STC) 37.26 V 16 panels 596.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Solartech Power SPM235P?

Four comparable CEC modules such as Gintech Energy GTE 235M (235.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintech Energy GTE 235M
Gintech Energy
235.0 W Tie (0 W) 37.32 V 13.97% 89.5%
APOS Energy AS235
APOS Energy
235.0 W Tie (0 W) 37.34 V 14.17% 89.7%
AXITEC AC-235P/156-60S
AXITEC
235.0 W Tie (0 W) 37.16 V 14.48% 90.0%
Advance Power API-M235
Advance Power
235.0 W Tie (0 W) 37.5 V 14.35% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solartech Power SPM235P?

Evaluate Solartech Power SPM235P (235.0 W STC, 37.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solartech Power SPM235P reaches 43.21 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 607 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (607 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solartech Power SPM235P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solartech Power SPM235P 8 kW Residential Fit

Needs 35 modules (607 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Gintech Energy GTE 235M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 210.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Power SPM235P by Solartech Power grounded in CEC test data and NEC 690.7/690.8 limits.

How many Solartech Power SPM235P panels fit on a 600 V winter solar string?

At -10 C (14 F), Solartech Power SPM235P cold Voc rises from 37.26 V to 41.89 V (beta_Voc -0.355%/C), capping a 600 V string at 14 panels (586.5 V).

How much roof area does an 8 kW array of Solartech Power SPM235P need?

An 8 kW DC system uses 35 Solartech Power SPM235P modules (8,225 W STC / 7,350 W PTC), covering roughly 607 sq ft and saving ~$2,057/yr at 18.54 c/kWh.

How does Solartech Power SPM235P compare against Gintech Energy GTE 235M?

Solartech Power SPM235P outputs 235.0 W STC (37.26 V Voc, rank #20,368 of 21,677), while Gintech Energy GTE 235M delivers 235.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.