Solartech Power SPM210P is a 210.0 W STC (176.5 W PTC) Multi-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 12.88% efficiency, 38.1 V Voc at 25 C, and 42.95 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 210.0 W
- PTC Wattage
- 176.5 W
- Voc @ 25C
- 38.1 V
- Efficiency
- 12.88%
How Does Solartech Power SPM210P Compare Against Peer CEC Listings?
Solar engineering breakdown for Solartech Power SPM210P: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Across 1,407 Multi-c-Si listings from Solartech Power and peers, Solartech Power SPM210P stands 68.8 W below the 278.8 W Multi-c-Si median and typical 84.0% PTC-to-STC thermal output (176.5 W real-world rating). Sizing 6 kW (29 panels) to 10 kW (48 panels) yields $1,524-$2,523/yr in baseline US bill offset. Lower 38.1 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does Solartech Power SPM210P Fall Across Listed CEC Models?
Distribution marker showing Solartech Power SPM210P (210.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define Solartech Power SPM210P?
Dataset percentiles tracking Solartech Power SPM210P power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Solartech Power SPM210P?
Benchmark highlights for Solartech Power SPM210P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
210.0 W STC · Higher Than 3.2%
210.0 W STC (-175.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
12.88% Aperture Efficiency
Power density 128.8 W/m2 (7.03 percentage points below 19.91% CEC median). PTC/STC ratio: 84.0% (rank #21,669).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.95 V at -10 C (558.4 V string) and 44.34 V at -20 C (13 max).
39 Panels = 8,190 W STC
Occupies 63.6 m2 (684 sq ft) producing 6,884 W PTC; NEC 690.8 OCPD floor is 12.67 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.1 * (1 + (-0.364/100) * (-10 - 25)) = 42.95 V | OCPD = 1.56 * 8.12 = 12.67 A
Inputs from CEC Modules.csv for Solartech Power SPM210P: Voc=38.1 V, beta_Voc=-0.364%/C, Isc=8.12 A, STC=210.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (558.4 V); 39 panels for 8 kW (684 sq ft).
What Are the Published CEC Specifications for Solartech Power SPM210P?
Official CEC datasheet figures for Solartech Power SPM210P (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 210.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 176.5 W (84.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.12 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.4 V / 7.14 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.364 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 12.88% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Solartech Power SPM210P Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Solartech Power SPM210P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 29 | 6.09 kW | 509 sq ft | $1,524 | $2,577 |
| 8 kW Class | 39 | 8.19 kW | 684 sq ft | $2,050 | $3,466 |
| 10 kW Class | 48 | 10.08 kW | 842 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Solartech Power Series?
Consolidated Solartech Power wattage variants sharing the Solartech Power SPM210P mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Solartech Power SPM200P | 200.0 W | 167.8 W | 36.5 V | 28.6 V | 12.27% |
| Solartech Power SPM205P | 205.0 W | 172.1 W | 37.1 V | 28.8 V | 12.58% |
| Solartech Power SPM210P | 210.0 W | 176.5 W | 38.1 V | 29.4 V | 12.88% |
| Solartech Power SPM220P | 220.0 W | 196.2 W | 36.9 V | 29.2 V | 13.67% |
How Many Solartech Power SPM210P Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Solartech Power SPM210P (42.95 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.34 V | 13 panels | 576.4 V | 22 panels |
| -10 C (14 F) | 42.95 V | 13 panels | 558.4 V | 23 panels |
| 0 C (32 F) | 41.57 V | 14 panels | 582.0 V | 24 panels |
| 25 C (77 F STC) | 38.1 V | 15 panels | 571.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Solartech Power SPM210P?
Competing CEC solar panels closest to Solartech Power SPM210P in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6P-210PX.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6P-210PX CSI Solar Co Ltd |
210.0 W | Tie (0 W) | 36.4 V | 13.06% | 91.6% |
| Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 Hanwha Qcells (Qidong) Co Ltd |
210.0 W | Tie (0 W) | 36.4 V | 12.71% | 90.0% |
| Hanwha Qcells (Qidong) Co Ltd SF220-30-P210 Hanwha Qcells (Qidong) Co Ltd |
210.0 W | Tie (0 W) | 36.2 V | 12.71% | 90.1% |
| Hanwha Qcells (Qidong) Co Ltd SF220-30-P210B Hanwha Qcells (Qidong) Co Ltd |
210.0 W | Tie (0 W) | 36.1 V | 12.71% | 89.5% |
What Are the Design Limits and Best-Fit Uses for Solartech Power SPM210P?
Evaluate Solartech Power SPM210P (210.0 W STC, 38.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solartech Power SPM210P reaches 44.34 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 39 panels for an 8 kW build require 684 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (684 sq ft).
- 2026 tax credit baseline: cash residential installs of Solartech Power SPM210P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solartech Power SPM210P 8 kW Residential Fit
Needs 39 modules (684 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS6P-210PX.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 176.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solartech Power SPM210P by Solartech Power grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Solartech Power SPM210P?
Multiplying Solartech Power SPM210P's 8.12 A short-circuit current by 1.56 equals 12.67 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Solartech Power SPM210P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.95 V cold Voc at 14 F and handles 8.12 A Isc; string inverters cap Solartech Power SPM210P at 13 panels on 600 V.
Is Solartech Power SPM210P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solartech Power SPM210P rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)