Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 is a 210.0 W STC (189.1 W PTC) Mono-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 12.71% efficiency, 36.4 V Voc at 25 C, and 40.72 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 210.0 W
- PTC Wattage
- 189.1 W
- Voc @ 25C
- 36.4 V
- Efficiency
- 12.71%
How Does Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 (Mono-c-Si) residential solar systems.
Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 delivers 127.1 W/m2 (7.20 percentage points below 19.91% CEC median) and typical 90.0% PTC-to-STC thermal output (189.1 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (693 sq ft). At -4 F (-20 C), string voltage climbs to 41.95 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with CSI Solar Co Ltd CS6P-210PX (210.0 W).
Where Does Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 Fall Across Listed CEC Models?
Comparison of Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 (210.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd SF220-30-M210?
Relative ranking of Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 across nameplate watts, 90.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd SF220-30-M210?
Summary of Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 output rank, 8 kW array size (39 panels), efficiency rating, and 600 V string limit.
210.0 W STC · Higher Than 3.2%
210.0 W STC (-175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
12.71% Aperture Efficiency
Power density 127.1 W/m2 (7.20 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.72 V at -10 C (570.1 V string) and 41.95 V at -20 C (14 max).
39 Panels = 8,190 W STC
Occupies 64.4 m2 (693 sq ft) producing 7,375 W PTC; NEC 690.8 OCPD floor is 12.17 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.4 * (1 + (-0.339/100) * (-10 - 25)) = 40.72 V | OCPD = 1.56 * 7.8 = 12.17 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd SF220-30-M210: Voc=36.4 V, beta_Voc=-0.339%/C, Isc=7.8 A, STC=210.0 W, Area=1.652 m2.
Result: 14 panels max on 600 V (570.1 V); 39 panels for 8 kW (693 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd SF220-30-M210?
Complete CEC test sheet for Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 including Isc (7.8 A), Voc (36.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 210.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 189.1 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.8 V / 7.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.339 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 12.71% (1.652 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hanwha Qcells (Qidong) Co Ltd SF220-30-M210.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 29 | 6.09 kW | 516 sq ft | $1,524 | $2,577 |
| 8 kW Class | 39 | 8.19 kW | 693 sq ft | $2,050 | $3,466 |
| 10 kW Class | 48 | 10.08 kW | 854 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Hanwha Qcells (Qidong) Co Ltd Series?
Related Hanwha Qcells (Qidong) Co Ltd power steps and black/silver trims consolidated into this Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hanwha Qcells (Qidong) Co Ltd SF220-30-M200 | 200.0 W | 179.9 W | 36.2 V | 29.6 V | 12.11% |
| Hanwha Qcells (Qidong) Co Ltd SF220-30-M205 | 205.0 W | 184.5 W | 36.3 V | 29.7 V | 12.41% |
| Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 | 210.0 W | 189.1 W | 36.4 V | 29.8 V | 12.71% |
| Hanwha Qcells (Qidong) Co Ltd SF220-30-M215 | 215.0 W | 193.7 W | 36.5 V | 29.9 V | 13.01% |
| Hanwha Qcells (Qidong) Co Ltd SF220-30-M220 | 220.0 W | 198.3 W | 36.6 V | 30.0 V | 13.32% |
How Many Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 (36.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.95 V | 14 panels | 587.3 V | 23 panels |
| -10 C (14 F) | 40.72 V | 14 panels | 570.1 V | 24 panels |
| 0 C (32 F) | 39.48 V | 15 panels | 592.2 V | 25 panels |
| 25 C (77 F STC) | 36.4 V | 16 panels | 582.4 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd SF220-30-M210?
Four comparable CEC modules such as CSI Solar Co Ltd CS6P-210PX (210.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6P-210PX CSI Solar Co Ltd |
210.0 W | Tie (0 W) | 36.4 V | 13.06% | 91.6% |
| Gintech Energy GTE 210M Gintech Energy |
210.0 W | Tie (0 W) | 35.92 V | 12.49% | 89.2% |
| Anji Dasol Solar Energy Science & Technology DS-A4-215 Anji Dasol Solar Energy Science & Technology |
215.0 W | +5.0 W | 36.3 V | 13.06% | 87.1% |
| APOS Energy AP215 APOS Energy |
215.0 W | +5.0 W | 36.79 V | 12.96% | 88.8% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd SF220-30-M210?
Evaluate Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 (210.0 W STC, 36.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 reaches 41.95 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 39 panels for an 8 kW build require 693 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (693 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 8 kW Residential Fit
Needs 39 modules (693 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6P-210PX.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 189.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 cold Voc rises from 36.4 V to 40.72 V (beta_Voc -0.339%/C), capping a 600 V string at 14 panels (570.1 V).
How much roof area does an 8 kW array of Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 need?
An 8 kW DC system uses 39 Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 modules (8,190 W STC / 7,375 W PTC), covering roughly 693 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 compare against CSI Solar Co Ltd CS6P-210PX?
Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 outputs 210.0 W STC (36.4 V Voc, rank #20,916 of 21,677), while CSI Solar Co Ltd CS6P-210PX delivers 210.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)