Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS6P-210PX — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS6P-210PX is a 210.0 W STC (192.3 W PTC) Multi-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 13.06% efficiency, 36.4 V Voc at 25 C, and 40.82 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
210.0 W
PTC Wattage
192.3 W
Voc @ 25C
36.4 V
Efficiency
13.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS6P-210PX Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CSI Solar Co Ltd CS6P-210PX (Multi-c-Si) residential solar systems.

CSI Solar Co Ltd CS6P-210PX delivers 130.5 W/m2 (6.85 percentage points below 19.91% CEC median) and strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (675 sq ft). At -4 F (-20 C), string voltage climbs to 42.08 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 (210.0 W).

Where Does CSI Solar Co Ltd CS6P-210PX Fall Across Listed CEC Models?

Comparison of CSI Solar Co Ltd CS6P-210PX (210.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS6P-210PX (210.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 210.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS6P-210PX?

Relative ranking of CSI Solar Co Ltd CS6P-210PX across nameplate watts, 91.6% PTC thermal ratio, and module aperture efficiency.

CSI Solar Co Ltd CS6P-210PX Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS6P-210PX wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage210.0 WPTC/STC Retention91.6%Module Efficiency13.06%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS6P-210PX?

Summary of CSI Solar Co Ltd CS6P-210PX output rank, 8 kW array size (39 panels), efficiency rating, and 600 V string limit.

Rank #20,916 / 21,677

210.0 W STC · Higher Than 3.2%

210.0 W STC (-175.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,384

13.06% Aperture Efficiency

Power density 130.5 W/m2 (6.85 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.82 V at -10 C (571.5 V string) and 42.08 V at -20 C (14 max).

8 kW Reference Array

39 Panels = 8,190 W STC

Occupies 62.8 m2 (675 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 12.34 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.4 * (1 + (-0.347/100) * (-10 - 25)) = 40.82 V | OCPD = 1.56 * 7.91 = 12.34 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS6P-210PX: Voc=36.4 V, beta_Voc=-0.347%/C, Isc=7.91 A, STC=210.0 W, Area=1.609 m2.

Result: 14 panels max on 600 V (571.5 V); 39 panels for 8 kW (675 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS6P-210PX?

Complete CEC test sheet for CSI Solar Co Ltd CS6P-210PX including Isc (7.91 A), Voc (36.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS6P-210PX.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 210.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 192.3 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 28.9 V / 7.26 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.347 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.06% (1.609 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many CSI Solar Co Ltd CS6P-210PX Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CSI Solar Co Ltd CS6P-210PX.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 29 6.09 kW 502 sq ft $1,524 $2,577
8 kW Class 39 8.19 kW 675 sq ft $2,050 $3,466
10 kW Class 48 10.08 kW 831 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?

Related CSI Solar Co Ltd power steps and black/silver trims consolidated into this CSI Solar Co Ltd CS6P-210PX series guide.

Sibling CEC listings grouped into the CSI Solar Co Ltd CS6P-210PX wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
CSI Solar Co Ltd CS6P-200PX 200.0 W 183.0 W 36.2 V 28.9 V 12.43%
CSI Solar Co Ltd CS6P-205PX 205.0 W 187.6 W 36.2 V 28.9 V 12.74%
CSI Solar Co Ltd CS6P-210PX 210.0 W 192.3 W 36.4 V 28.9 V 13.06%
CSI Solar Co Ltd CS6P-215PX 215.0 W 197.0 W 36.5 V 29.0 V 13.37%
CSI Solar Co Ltd CS6P-220PX 220.0 W 201.6 W 36.6 V 29.3 V 13.68%

How Many CSI Solar Co Ltd CS6P-210PX Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for CSI Solar Co Ltd CS6P-210PX (36.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.4V and beta_Voc=-0.347%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.08 V 14 panels 589.1 V 23 panels
-10 C (14 F) 40.82 V 14 panels 571.5 V 24 panels
0 C (32 F) 39.56 V 15 panels 593.4 V 25 panels
25 C (77 F STC) 36.4 V 16 panels 582.4 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS6P-210PX?

Four comparable CEC modules such as Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 (210.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd SF220-30-M210
Hanwha Qcells (Qidong) Co Ltd
210.0 W Tie (0 W) 36.4 V 12.71% 90.0%
Hanwha Qcells (Qidong) Co Ltd SF220-30-P210
Hanwha Qcells (Qidong) Co Ltd
210.0 W Tie (0 W) 36.2 V 12.71% 90.1%
Hanwha Qcells (Qidong) Co Ltd SF220-30-P210B
Hanwha Qcells (Qidong) Co Ltd
210.0 W Tie (0 W) 36.1 V 12.71% 89.5%
Gintech Energy GTE 210M
Gintech Energy
210.0 W Tie (0 W) 35.92 V 12.49% 89.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS6P-210PX?

Evaluate CSI Solar Co Ltd CS6P-210PX (210.0 W STC, 36.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS6P-210PX reaches 42.08 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 39 panels for an 8 kW build require 675 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (675 sq ft).
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS6P-210PX carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS6P-210PX 8 kW Residential Fit

Needs 39 modules (675 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF220-30-M210.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 192.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS6P-210PX by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many CSI Solar Co Ltd CS6P-210PX panels fit on a 600 V winter solar string?

At -10 C (14 F), CSI Solar Co Ltd CS6P-210PX cold Voc rises from 36.4 V to 40.82 V (beta_Voc -0.347%/C), capping a 600 V string at 14 panels (571.5 V).

How much roof area does an 8 kW array of CSI Solar Co Ltd CS6P-210PX need?

An 8 kW DC system uses 39 CSI Solar Co Ltd CS6P-210PX modules (8,190 W STC / 7,500 W PTC), covering roughly 675 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does CSI Solar Co Ltd CS6P-210PX compare against Hanwha Qcells (Qidong) Co Ltd SF220-30-M210?

CSI Solar Co Ltd CS6P-210PX outputs 210.0 W STC (36.4 V Voc, rank #20,916 of 21,677), while Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 delivers 210.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.