Skip to main content
WireAndSun
Calculators
CEC PV Module

APOS Energy AP195 — CEC Solar Module Specifications

Manufacturer: APOS Energy Registry: CEC Verified Engineering Specification

APOS Energy AP195 is a 195.0 W STC (173.1 W PTC) Multi-c-Si solar module ranking #21,088 of 21,677 CEC listings (below all-CEC median; higher than 2.5% of peers). It delivers 13.0% efficiency, 33.11 V Voc at 25 C, and 36.54 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
195.0 W
PTC Wattage
173.1 W
Voc @ 25C
33.11 V
Efficiency
13.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does APOS Energy AP195 Compare Against Peer CEC Listings?

Solar engineering breakdown for APOS Energy AP195: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Across 1,407 Multi-c-Si listings from APOS Energy and peers, APOS Energy AP195 stands 83.8 W below the 278.8 W Multi-c-Si median and typical 88.8% PTC-to-STC thermal output (173.1 W real-world rating). Sizing 6 kW (31 panels) to 10 kW (52 panels) yields $1,512-$2,538/yr in baseline US bill offset. Lower 33.11 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.

Where Does APOS Energy AP195 Fall Across Listed CEC Models?

Distribution marker showing APOS Energy AP195 (195.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where APOS Energy AP195 (195.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAPOS Energy AP195: 195.0 W

What Dataset Percentiles Define APOS Energy AP195?

Dataset percentiles tracking APOS Energy AP195 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

APOS Energy AP195 Engineering BenchmarksPercentile comparison of APOS Energy AP195 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage195.0 WPTC/STC Retention88.8%Module Efficiency13.0%

What Do the Dataset Ranks Show for APOS Energy AP195?

Benchmark highlights for APOS Energy AP195 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #21,088 / 21,677

195.0 W STC · Higher Than 2.5%

195.0 W STC (-190.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,409

13.0% Aperture Efficiency

Power density 130.0 W/m2 (6.91 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 36.54 V at -10 C (584.6 V string) and 37.52 V at -20 C (15 max).

8 kW Reference Array

42 Panels = 8,190 W STC

Occupies 63.0 m2 (678 sq ft) producing 7,270 W PTC; NEC 690.8 OCPD floor is 12.26 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.11 * (1 + (-0.296/100) * (-10 - 25)) = 36.54 V | OCPD = 1.56 * 7.86 = 12.26 A

Inputs from CEC Modules.csv for APOS Energy AP195: Voc=33.11 V, beta_Voc=-0.296%/C, Isc=7.86 A, STC=195.0 W, Area=1.5 m2.

Result: 16 panels max on 600 V (584.6 V); 42 panels for 8 kW (678 sq ft).

What Are the Published CEC Specifications for APOS Energy AP195?

Official CEC datasheet figures for APOS Energy AP195 (Multi-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for APOS Energy AP195.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 195.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 173.1 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.11 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 26.06 V / 7.43 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.296 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.0% (1.5 m2) Array roof footprint density
Cell Count & Technology 54 cells (Multi-c-Si) Monofacial backsheet

How Many APOS Energy AP195 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many APOS Energy AP195 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 31 6.04 kW 501 sq ft $1,512 $2,556
8 kW Class 42 8.19 kW 678 sq ft $2,050 $3,466
10 kW Class 52 10.14 kW 840 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This APOS Energy Series?

Consolidated APOS Energy wattage variants sharing the APOS Energy AP195 mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the APOS Energy AP195 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
APOS Energy AP190 190.0 W 168.6 W 32.89 V 25.76 V 12.67%
APOS Energy AP195 195.0 W 173.1 W 33.11 V 26.06 V 13.0%

How Many APOS Energy AP195 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on APOS Energy AP195 (36.54 V at 14 F).

Computed from Voc=33.11V and beta_Voc=-0.296%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 37.52 V 15 panels 562.8 V 26 panels
-10 C (14 F) 36.54 V 16 panels 584.6 V 27 panels
0 C (32 F) 35.56 V 16 panels 569.0 V 28 panels
25 C (77 F STC) 33.11 V 18 panels 596.0 V 30 panels

Which Cross-Brand Solar Modules Compare Closest to APOS Energy AP195?

Competing CEC solar panels closest to APOS Energy AP195 in nameplate wattage and Voc, starting with Gintung Energy ASEC-195G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-195G6S
Gintung Energy
195.0 W Tie (0 W) 32.95 V 13.86% 89.4%
Gintung Energy ASEC-195G6M
Gintung Energy
195.0 W Tie (0 W) 32.94 V 13.86% 88.4%
United Renewable Energy Co Ltd D6P195A5F
United Renewable Energy Co Ltd
195.0 W Tie (0 W) 32.94 V 13.86% 88.4%
Guangdong Golden Glass Technologies GG195M2-27/1482x992
Guangdong Golden Glass Technologies
195.0 W Tie (0 W) 32.8 V 13.26% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for APOS Energy AP195?

Evaluate APOS Energy AP195 (195.0 W STC, 33.11 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), APOS Energy AP195 reaches 37.52 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 42 panels for an 8 kW build require 678 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 42 panels (678 sq ft).
  • 2026 tax credit baseline: cash residential installs of APOS Energy AP195 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

APOS Energy AP195 8 kW Residential Fit

Needs 42 modules (678 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare Gintung Energy ASEC-195G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 173.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for APOS Energy AP195 by APOS Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for APOS Energy AP195?

Multiplying APOS Energy AP195's 7.86 A short-circuit current by 1.56 equals 12.26 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can APOS Energy AP195 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 36.54 V cold Voc at 14 F and handles 7.86 A Isc; string inverters cap APOS Energy AP195 at 16 panels on 600 V.

Is APOS Energy AP195 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of APOS Energy AP195 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.