APOS Energy AP195 is a 195.0 W STC (173.1 W PTC) Multi-c-Si solar module ranking #21,088 of 21,677 CEC listings (below all-CEC median; higher than 2.5% of peers). It delivers 13.0% efficiency, 33.11 V Voc at 25 C, and 36.54 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 195.0 W
- PTC Wattage
- 173.1 W
- Voc @ 25C
- 33.11 V
- Efficiency
- 13.0%
How Does APOS Energy AP195 Compare Against Peer CEC Listings?
Solar engineering breakdown for APOS Energy AP195: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Across 1,407 Multi-c-Si listings from APOS Energy and peers, APOS Energy AP195 stands 83.8 W below the 278.8 W Multi-c-Si median and typical 88.8% PTC-to-STC thermal output (173.1 W real-world rating). Sizing 6 kW (31 panels) to 10 kW (52 panels) yields $1,512-$2,538/yr in baseline US bill offset. Lower 33.11 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.
Where Does APOS Energy AP195 Fall Across Listed CEC Models?
Distribution marker showing APOS Energy AP195 (195.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define APOS Energy AP195?
Dataset percentiles tracking APOS Energy AP195 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for APOS Energy AP195?
Benchmark highlights for APOS Energy AP195 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
195.0 W STC · Higher Than 2.5%
195.0 W STC (-190.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.0% Aperture Efficiency
Power density 130.0 W/m2 (6.91 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 36.54 V at -10 C (584.6 V string) and 37.52 V at -20 C (15 max).
42 Panels = 8,190 W STC
Occupies 63.0 m2 (678 sq ft) producing 7,270 W PTC; NEC 690.8 OCPD floor is 12.26 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 33.11 * (1 + (-0.296/100) * (-10 - 25)) = 36.54 V | OCPD = 1.56 * 7.86 = 12.26 A
Inputs from CEC Modules.csv for APOS Energy AP195: Voc=33.11 V, beta_Voc=-0.296%/C, Isc=7.86 A, STC=195.0 W, Area=1.5 m2.
Result: 16 panels max on 600 V (584.6 V); 42 panels for 8 kW (678 sq ft).
What Are the Published CEC Specifications for APOS Energy AP195?
Official CEC datasheet figures for APOS Energy AP195 (Multi-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 195.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 173.1 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 33.11 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 26.06 V / 7.43 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.296 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.0% (1.5 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Multi-c-Si) | Monofacial backsheet |
How Many APOS Energy AP195 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many APOS Energy AP195 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 31 | 6.04 kW | 501 sq ft | $1,512 | $2,556 |
| 8 kW Class | 42 | 8.19 kW | 678 sq ft | $2,050 | $3,466 |
| 10 kW Class | 52 | 10.14 kW | 840 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This APOS Energy Series?
Consolidated APOS Energy wattage variants sharing the APOS Energy AP195 mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| APOS Energy AP190 | 190.0 W | 168.6 W | 32.89 V | 25.76 V | 12.67% |
| APOS Energy AP195 | 195.0 W | 173.1 W | 33.11 V | 26.06 V | 13.0% |
How Many APOS Energy AP195 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on APOS Energy AP195 (36.54 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 37.52 V | 15 panels | 562.8 V | 26 panels |
| -10 C (14 F) | 36.54 V | 16 panels | 584.6 V | 27 panels |
| 0 C (32 F) | 35.56 V | 16 panels | 569.0 V | 28 panels |
| 25 C (77 F STC) | 33.11 V | 18 panels | 596.0 V | 30 panels |
Which Cross-Brand Solar Modules Compare Closest to APOS Energy AP195?
Competing CEC solar panels closest to APOS Energy AP195 in nameplate wattage and Voc, starting with Gintung Energy ASEC-195G6S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-195G6S Gintung Energy |
195.0 W | Tie (0 W) | 32.95 V | 13.86% | 89.4% |
| Gintung Energy ASEC-195G6M Gintung Energy |
195.0 W | Tie (0 W) | 32.94 V | 13.86% | 88.4% |
| United Renewable Energy Co Ltd D6P195A5F United Renewable Energy Co Ltd |
195.0 W | Tie (0 W) | 32.94 V | 13.86% | 88.4% |
| Guangdong Golden Glass Technologies GG195M2-27/1482x992 Guangdong Golden Glass Technologies |
195.0 W | Tie (0 W) | 32.8 V | 13.26% | 89.8% |
What Are the Design Limits and Best-Fit Uses for APOS Energy AP195?
Evaluate APOS Energy AP195 (195.0 W STC, 33.11 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), APOS Energy AP195 reaches 37.52 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 42 panels for an 8 kW build require 678 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 42 panels (678 sq ft).
- 2026 tax credit baseline: cash residential installs of APOS Energy AP195 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
APOS Energy AP195 8 kW Residential Fit
Needs 42 modules (678 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare Gintung Energy ASEC-195G6S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 173.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for APOS Energy AP195 by APOS Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for APOS Energy AP195?
Multiplying APOS Energy AP195's 7.86 A short-circuit current by 1.56 equals 12.26 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can APOS Energy AP195 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 36.54 V cold Voc at 14 F and handles 7.86 A Isc; string inverters cap APOS Energy AP195 at 16 panels on 600 V.
Is APOS Energy AP195 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of APOS Energy AP195 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)