Sunflare Co FLEX60-185W-M20 — CEC Solar Module Specifications

Manufacturer: Sunflare Co Registry: CEC Verified Engineering Specification

Sunflare Co FLEX60-185W-M20 is a 185.0 W STC (183.8 W PTC) Thin Film solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 11.28% efficiency, 36.63 V Voc at 25 C, and 40.46 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
185.0 W
PTC Wattage
183.8 W
Voc @ 25C
36.63 V
Efficiency
11.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sunflare Co FLEX60-185W-M20 Compare Against Peer CEC Listings?

Solar engineering breakdown for Sunflare Co FLEX60-185W-M20: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Across 106 Thin Film listings from Sunflare Co and peers, Sunflare Co FLEX60-185W-M20 stands 67.5 W above the 117.5 W Thin Film median and strong 99.4% PTC-to-STC heat retention (#1 of 21,677). Sizing 6 kW (33 panels) to 10 kW (55 panels) yields $1,529-$2,548/yr in baseline US bill offset. Lower 36.63 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Sunflare Co FLEX60-185W-M20 Fall Across Listed CEC Models?

Distribution marker showing Sunflare Co FLEX60-185W-M20 (185.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sunflare Co FLEX60-185W-M20 (185.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunflare Co FLEX60: 185.0 W

What Dataset Percentiles Define Sunflare Co FLEX60-185W-M20?

Dataset percentiles tracking Sunflare Co FLEX60-185W-M20 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sunflare Co FLEX60-185W-M20 Engineering BenchmarksPercentile comparison of Sunflare Co FLEX60-185W-M20 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage185.0 WPTC/STC Retention99.4%Module Efficiency11.28%

What Do the Dataset Ranks Show for Sunflare Co FLEX60-185W-M20?

Benchmark highlights for Sunflare Co FLEX60-185W-M20 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #21,185 / 21,677

185.0 W STC · Higher Than 2.1%

185.0 W STC (-200.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,592

11.28% Aperture Efficiency

Power density 112.8 W/m2 (8.63 percentage points below 19.91% CEC median). PTC/STC ratio: 99.4% (rank #1).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.46 V at -10 C (566.4 V string) and 41.56 V at -20 C (14 max).

8 kW Reference Array

44 Panels = 8,140 W STC

Occupies 72.2 m2 (777 sq ft) producing 8,087 W PTC; NEC 690.8 OCPD floor is 11.75 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.63 * (1 + (-0.299/100) * (-10 - 25)) = 40.46 V | OCPD = 1.56 * 7.53 = 11.75 A

Inputs from CEC Modules.csv for Sunflare Co FLEX60-185W-M20: Voc=36.63 V, beta_Voc=-0.299%/C, Isc=7.53 A, STC=185.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (566.4 V); 44 panels for 8 kW (777 sq ft).

What Are the Published CEC Specifications for Sunflare Co FLEX60-185W-M20?

Official CEC datasheet figures for Sunflare Co FLEX60-185W-M20 (Thin Film) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for Sunflare Co FLEX60-185W-M20.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 185.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 183.8 W (99.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.63 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.53 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 28.33 V / 6.53 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.299 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 11.28% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Thin Film) Monofacial backsheet

How Many Sunflare Co FLEX60-185W-M20 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Sunflare Co FLEX60-185W-M20 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 33 6.11 kW 583 sq ft $1,529 $2,586
8 kW Class 44 8.14 kW 777 sq ft $2,037 $3,445
10 kW Class 55 10.18 kW 971 sq ft $2,548 $4,308

Which Sibling Wattage & Trim Variants Belong to This Sunflare Co Series?

Consolidated Sunflare Co wattage variants sharing the Sunflare Co FLEX60-185W-M20 mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Sunflare Co FLEX60-185W-M20 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Sunflare Co FLEX60-175W-M20 175.0 W 173.8 W 35.95 V 28.18 V 10.67%
Sunflare Co FLEX60-180W-M20 180.0 W 178.8 W 36.4 V 28.68 V 10.98%
Sunflare Co FLEX60-185W-M20 185.0 W 183.8 W 36.63 V 28.33 V 11.28%
Sunflare Co FLEX60-190W-M20 190.0 W 188.8 W 36.93 V 29.26 V 11.59%
Sunflare Co FLEX60-195W-M20 195.0 W 193.7 W 37.6 V 29.86 V 11.89%

How Many Sunflare Co FLEX60-185W-M20 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Sunflare Co FLEX60-185W-M20 (40.46 V at 14 F).

Computed from Voc=36.63V and beta_Voc=-0.299%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.56 V 14 panels 581.8 V 24 panels
-10 C (14 F) 40.46 V 14 panels 566.4 V 24 panels
0 C (32 F) 39.37 V 15 panels 590.5 V 25 panels
25 C (77 F STC) 36.63 V 16 panels 586.1 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Sunflare Co FLEX60-185W-M20?

Competing CEC solar panels closest to Sunflare Co FLEX60-185W-M20 in nameplate wattage and Voc, starting with Solartech Power SPM195P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Solartech Power SPM195P
Solartech Power
195.0 W +10.0 W 35.6 V 11.96% 83.8%
Hanwha Qcells (Qidong) Co Ltd SF190-27-P185
Hanwha Qcells (Qidong) Co Ltd
185.0 W Tie (0 W) 32.5 V 12.38% 88.6%
Hanwha Qcells (Qidong) Co Ltd SF190-27-M190
Hanwha Qcells (Qidong) Co Ltd
190.0 W +5.0 W 32.8 V 12.72% 88.7%
Hanwha Qcells (Qidong) Co Ltd SF190-27-M190B
Hanwha Qcells (Qidong) Co Ltd
190.0 W +5.0 W 32.8 V 12.72% 88.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sunflare Co FLEX60-185W-M20?

Evaluate Sunflare Co FLEX60-185W-M20 (185.0 W STC, 36.63 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sunflare Co FLEX60-185W-M20 reaches 41.56 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 44 panels for an 8 kW build require 777 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (777 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sunflare Co FLEX60-185W-M20 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sunflare Co FLEX60-185W-M20 8 kW Residential Fit

Needs 44 modules (777 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Solartech Power SPM195P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 183.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunflare Co FLEX60-185W-M20 by Sunflare Co grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Sunflare Co FLEX60-185W-M20?

Multiplying Sunflare Co FLEX60-185W-M20's 7.53 A short-circuit current by 1.56 equals 11.75 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Sunflare Co FLEX60-185W-M20 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.46 V cold Voc at 14 F and handles 7.53 A Isc; string inverters cap Sunflare Co FLEX60-185W-M20 at 14 panels on 600 V.

Is Sunflare Co FLEX60-185W-M20 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunflare Co FLEX60-185W-M20 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.