Manufacturer: Sunflare Co Registry: CEC Verified Engineering Specification

Sunflare Co FLEX60-165W is a 165.0 W STC (142.9 W PTC) Thin Film solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 10.06% efficiency, 35.42 V Voc at 25 C, and 39.3 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
165.0 W
PTC Wattage
142.9 W
Voc @ 25C
35.42 V
Efficiency
10.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sunflare Co FLEX60-165W Compare Against Peer CEC Listings?

How Sunflare Co Sunflare Co FLEX60-165W handles rooftop heat (142.9 W PTC), 8 kW sizing, and cold winter string voltage.

Sunflare Co builds the Sunflare Co FLEX60-165W (Thin Film) as a compact residential or specialty off-grid module delivering 100.6 W/m2 (9.85 percentage points below 19.91% CEC median). Compared against Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 (170.0 W), this model holds typical 86.6% PTC-to-STC thermal output (142.9 W real-world rating). Lower 35.42 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 11.36 A overcurrent floor served by a 15 A breaker.

Where Does Sunflare Co FLEX60-165W Fall Across Listed CEC Models?

Where Sunflare Co FLEX60-165W (165.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sunflare Co FLEX60-165W (165.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunflare Co FLEX60: 165.0 W

What Dataset Percentiles Define Sunflare Co FLEX60-165W?

Percentile placement of Sunflare Co FLEX60-165W across power density (100.6 W/m2), thermal retention, and nameplate STC wattage.

Sunflare Co FLEX60-165W Engineering BenchmarksPercentile comparison of Sunflare Co FLEX60-165W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage165.0 WPTC/STC Retention86.6%Module Efficiency10.06%

What Do the Dataset Ranks Show for Sunflare Co FLEX60-165W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Sunflare Co FLEX60-165W specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #21,351 / 21,677

165.0 W STC · Higher Than 1.4%

165.0 W STC (-220.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,625

10.06% Aperture Efficiency

Power density 100.6 W/m2 (9.85 percentage points below 19.91% CEC median). PTC/STC ratio: 86.6% (rank #21,610).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 39.3 V at -10 C (589.5 V string) and 40.41 V at -20 C (14 max).

8 kW Reference Array

49 Panels = 8,085 W STC

Occupies 80.4 m2 (865 sq ft) producing 7,002 W PTC; NEC 690.8 OCPD floor is 11.36 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.42 * (1 + (-0.313/100) * (-10 - 25)) = 39.3 V | OCPD = 1.56 * 7.28 = 11.36 A

Inputs from CEC Modules.csv for Sunflare Co FLEX60-165W: Voc=35.42 V, beta_Voc=-0.313%/C, Isc=7.28 A, STC=165.0 W, Area=1.64 m2.

Result: 15 panels max on 600 V (589.5 V); 49 panels for 8 kW (865 sq ft).

What Are the Published CEC Specifications for Sunflare Co FLEX60-165W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Sunflare Co FLEX60-165W.

Official California Energy Commission (NREL SAM) test parameters for Sunflare Co FLEX60-165W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 165.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 142.9 W (86.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.42 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.28 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 27.5 V / 6.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.313 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 10.06% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Thin Film) Monofacial backsheet

How Many Sunflare Co FLEX60-165W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Sunflare Co FLEX60-165W (165.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 37 6.11 kW 653 sq ft $1,529 $2,586
8 kW Class 49 8.09 kW 865 sq ft $2,025 $3,424
10 kW Class 61 10.06 kW 1,077 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This Sunflare Co Series?

All closely matched Sunflare Co wattages and cosmetic trims sharing the Sunflare Co FLEX60-165W architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Sunflare Co FLEX60-165W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Sunflare Co FLEX60-160W 160.0 W 138.5 W 35.11 V 27.63 V 9.76%
Sunflare Co FLEX60-165W 165.0 W 142.9 W 35.42 V 27.5 V 10.06%
Sunflare Co FLEX60-170W 170.0 W 147.3 W 35.74 V 27.37 V 10.37%

How Many Sunflare Co FLEX60-165W Modules Fit in a Cold-Weather String?

Maximum series module counts for Sunflare Co FLEX60-165W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=35.42V and beta_Voc=-0.313%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 40.41 V 14 panels 565.7 V 24 panels
-10 C (14 F) 39.3 V 15 panels 589.5 V 25 panels
0 C (32 F) 38.19 V 15 panels 572.8 V 26 panels
25 C (77 F STC) 35.42 V 16 panels 566.7 V 28 panels

Which Cross-Brand Solar Modules Compare Closest to Sunflare Co FLEX60-165W?

Alternative CEC solar modules from competing brands near Sunflare Co FLEX60-165W (165.0 W), including Hanwha Qcells (Qidong) Co Ltd SF190-27-P170.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd SF190-27-P170
Hanwha Qcells (Qidong) Co Ltd
170.0 W +5.0 W 32.2 V 11.38% 88.5%
Lightway Green New Energy LW165(23)P1310x990
Lightway Green New Energy
165.0 W Tie (0 W) 29.0 V 10.19% 88.8%
Juli New Energy JLS165M
Juli New Energy
165.0 W Tie (0 W) 42.0 V 12.92% 85.8%
Guangdong Golden Glass Technologies GG165M2-24/1324x992
Guangdong Golden Glass Technologies
165.0 W Tie (0 W) 28.8 V 12.56% 89.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sunflare Co FLEX60-165W?

Evaluate Sunflare Co FLEX60-165W (165.0 W STC, 35.42 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sunflare Co FLEX60-165W reaches 40.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 49 panels for an 8 kW build require 865 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (865 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sunflare Co FLEX60-165W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sunflare Co FLEX60-165W 8 kW Residential Fit

Needs 49 modules (865 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF190-27-P170.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 142.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunflare Co FLEX60-165W by Sunflare Co grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Sunflare Co FLEX60-165W?

Multiplying Sunflare Co FLEX60-165W's 7.28 A short-circuit current by 1.56 equals 11.36 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Sunflare Co FLEX60-165W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 39.3 V cold Voc at 14 F and handles 7.28 A Isc; string inverters cap Sunflare Co FLEX60-165W at 15 panels on 600 V.

Is Sunflare Co FLEX60-165W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunflare Co FLEX60-165W rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.