Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 is a 170.0 W STC (150.4 W PTC) Multi-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 11.38% efficiency, 32.2 V Voc at 25 C, and 35.85 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 170.0 W
- PTC Wattage
- 150.4 W
- Voc @ 25C
- 32.2 V
- Efficiency
- 11.38%
How Does Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 (Multi-c-Si) residential solar systems.
Homeowners evaluating Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 need 36 panels for 6 kW or 48 panels (772 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (772 sq ft). Under NEC 690.7(A), beta_Voc (-0.324%/C) pushes open-circuit voltage to 35.85 V at 14 F and 36.89 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 Fall Across Listed CEC Models?
Comparison of Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 (170.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd SF190-27-P170?
Relative ranking of Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 across nameplate watts, 88.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170?
Summary of Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 output rank, 8 kW array size (48 panels), efficiency rating, and 600 V string limit.
170.0 W STC · Higher Than 1.5%
170.0 W STC (-215.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
11.38% Aperture Efficiency
Power density 113.8 W/m2 (8.53 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 35.85 V at -10 C (573.6 V string) and 36.89 V at -20 C (16 max).
48 Panels = 8,160 W STC
Occupies 71.7 m2 (772 sq ft) producing 7,219 W PTC; NEC 690.8 OCPD floor is 11.76 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 32.2 * (1 + (-0.324/100) * (-10 - 25)) = 35.85 V | OCPD = 1.56 * 7.54 = 11.76 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170: Voc=32.2 V, beta_Voc=-0.324%/C, Isc=7.54 A, STC=170.0 W, Area=1.494 m2.
Result: 16 panels max on 600 V (573.6 V); 48 panels for 8 kW (772 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170?
Complete CEC test sheet for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 including Isc (7.54 A), Voc (32.2 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 170.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 150.4 W (88.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 32.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 26.3 V / 6.47 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 11.38% (1.494 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hanwha Qcells (Qidong) Co Ltd SF190-27-P170.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 36 | 6.12 kW | 579 sq ft | $1,532 | $2,590 |
| 8 kW Class | 48 | 8.16 kW | 772 sq ft | $2,042 | $3,454 |
| 10 kW Class | 59 | 10.03 kW | 949 sq ft | $2,510 | $4,245 |
How Many Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 (32.2 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 36.89 V | 16 panels | 590.2 V | 27 panels |
| -10 C (14 F) | 35.85 V | 16 panels | 573.6 V | 27 panels |
| 0 C (32 F) | 34.81 V | 17 panels | 591.8 V | 28 panels |
| 25 C (77 F STC) | 32.2 V | 18 panels | 579.6 V | 31 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd SF190-27-P170?
Four comparable CEC modules such as Mitsubishi Electric PV-MF170UD4 (170.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Mitsubishi Electric PV-MF170UD4 Mitsubishi Electric |
170.0 W | Tie (0 W) | 29.9 V | 12.28% | 89.2% |
| Mitsubishi Electric PV-UD170MF5 Mitsubishi Electric |
170.0 W | Tie (0 W) | 29.9 V | 12.29% | 88.8% |
| Lightway Green New Energy LW170(23)P1310x990 Lightway Green New Energy |
170.0 W | Tie (0 W) | 29.5 V | 13.25% | 89.4% |
| WAAREE ENERGIES LIMITED WU-180 WAAREE ENERGIES LIMITED |
180.0 W | +10.0 W | 32.0 V | 12.2% | 88.7% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170?
Evaluate Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 (170.0 W STC, 32.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 reaches 36.89 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
- Footprint constraint: 48 panels for an 8 kW build require 772 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (772 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 8 kW Residential Fit
Needs 48 modules (772 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare Mitsubishi Electric PV-MF170UD4.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 150.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 PTC wattage (150.4 W) lower than STC (170.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 150.4 W PTC (88.5% retention) across Hanwha Qcells (Qidong) Co Ltd SF190-27-P170's 1.494 m2 aperture.
Who should skip Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 48 Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 panels (772 sq ft) leave unusable roof gaps vs. Mitsubishi Electric PV-MF170UD4.
What is the 1,000 V commercial string limit for Hanwha Qcells (Qidong) Co Ltd SF190-27-P170?
On 1,000 V commercial inverters at -10 C (35.85 V cold Voc), Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 fits up to 27 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)