WAAREE ENERGIES LIMITED WU-180 is a 180.0 W STC (159.7 W PTC) Multi-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 12.2% efficiency, 32.0 V Voc at 25 C, and 36.01 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 180.0 W
- PTC Wattage
- 159.7 W
- Voc @ 25C
- 32.0 V
- Efficiency
- 12.2%
How Does WAAREE ENERGIES LIMITED WU-180 Compare Against Peer CEC Listings?
Engineering position of WAAREE ENERGIES LIMITED WU-180 (180.0 W STC) vs. Mitsubishi Electric PV-MF180UD4 across 1,407 CEC Multi-c-Si solar modules.
Ranking #21,232 across 21,677 CEC solar panels (below all-CEC median; higher than 1.8% of peers), WAAREE ENERGIES LIMITED WU-180 operates as a compact residential or specialty off-grid module sitting 98.8 W below the 278.8 W Multi-c-Si median. Lower 32.0 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters. With typical 88.7% PTC-to-STC thermal output (159.7 W real-world rating), 45 panels occupy 714 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does WAAREE ENERGIES LIMITED WU-180 Fall Across Listed CEC Models?
Plots WAAREE ENERGIES LIMITED WU-180 at 180.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-180?
Benchmarks WAAREE ENERGIES LIMITED WU-180 on STC wattage, thermal PTC/STC retention, and 12.2 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-180?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for WAAREE ENERGIES LIMITED WU-180 by WAAREE ENERGIES LIMITED.
180.0 W STC · Higher Than 1.8%
180.0 W STC (-205.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
12.2% Aperture Efficiency
Power density 122.0 W/m2 (7.71 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 36.01 V at -10 C (576.2 V string) and 37.16 V at -20 C (16 max).
45 Panels = 8,100 W STC
Occupies 66.4 m2 (714 sq ft) producing 7,186 W PTC; NEC 690.8 OCPD floor is 12.17 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 32.0 * (1 + (-0.358/100) * (-10 - 25)) = 36.01 V | OCPD = 1.56 * 7.8 = 12.17 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-180: Voc=32.0 V, beta_Voc=-0.358%/C, Isc=7.8 A, STC=180.0 W, Area=1.475 m2.
Result: 16 panels max on 600 V (576.2 V); 45 panels for 8 kW (714 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-180?
Laboratory test ratings recorded for WAAREE ENERGIES LIMITED WU-180 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 180.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 159.7 W (88.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 32.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 26.0 V / 6.9 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.358 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 12.2% (1.475 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many WAAREE ENERGIES LIMITED WU-180 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (714 sq ft at 8 kW), and estimated Year-1 electric bill offset for WAAREE ENERGIES LIMITED WU-180.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 34 | 6.12 kW | 540 sq ft | $1,532 | $2,590 |
| 8 kW Class | 45 | 8.1 kW | 714 sq ft | $2,027 | $3,428 |
| 10 kW Class | 56 | 10.08 kW | 889 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?
Sibling wattage bins and frame colors grouped with WAAREE ENERGIES LIMITED WU-180 under WAAREE ENERGIES LIMITED to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| WAAREE ENERGIES LIMITED WU-175 | 175.0 W | 155.1 W | 32.0 V | 26.0 V | 11.86% |
| WAAREE ENERGIES LIMITED WU-180 | 180.0 W | 159.7 W | 32.0 V | 26.0 V | 12.2% |
How Many WAAREE ENERGIES LIMITED WU-180 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for WAAREE ENERGIES LIMITED WU-180 (beta_Voc -0.358%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 37.16 V | 16 panels | 594.6 V | 26 panels |
| -10 C (14 F) | 36.01 V | 16 panels | 576.2 V | 27 panels |
| 0 C (32 F) | 34.86 V | 17 panels | 592.6 V | 28 panels |
| 25 C (77 F STC) | 32.0 V | 18 panels | 576.0 V | 31 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-180?
Closest cross-brand CEC competitors to WAAREE ENERGIES LIMITED WU-180 matched near 180.0 W STC and 32.0 V Voc, led by Mitsubishi Electric PV-MF180UD4.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Mitsubishi Electric PV-MF180UD4 Mitsubishi Electric |
180.0 W | Tie (0 W) | 30.4 V | 13.0% | 89.3% |
| Hanwha Qcells (Qidong) Co Ltd SF190-27-P185 Hanwha Qcells (Qidong) Co Ltd |
185.0 W | +5.0 W | 32.5 V | 12.38% | 88.6% |
| Gintung Energy ASEC-180G6S Gintung Energy |
180.0 W | Tie (0 W) | 29.73 V | 13.8% | 88.7% |
| APOS Energy AP180 APOS Energy |
180.0 W | Tie (0 W) | 29.72 V | 13.42% | 88.9% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-180?
Evaluate WAAREE ENERGIES LIMITED WU-180 (180.0 W STC, 32.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-180 reaches 37.16 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
- Footprint constraint: 45 panels for an 8 kW build require 714 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (714 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-180 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED WU-180 8 kW Residential Fit
Needs 45 modules (714 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare Mitsubishi Electric PV-MF180UD4.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 159.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED WU-180 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
How many WAAREE ENERGIES LIMITED WU-180 panels fit on a 600 V winter solar string?
At -10 C (14 F), WAAREE ENERGIES LIMITED WU-180 cold Voc rises from 32.0 V to 36.01 V (beta_Voc -0.358%/C), capping a 600 V string at 16 panels (576.2 V).
How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED WU-180 need?
An 8 kW DC system uses 45 WAAREE ENERGIES LIMITED WU-180 modules (8,100 W STC / 7,186 W PTC), covering roughly 714 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does WAAREE ENERGIES LIMITED WU-180 compare against Mitsubishi Electric PV-MF180UD4?
WAAREE ENERGIES LIMITED WU-180 outputs 180.0 W STC (32.0 V Voc, rank #21,232 of 21,677), while Mitsubishi Electric PV-MF180UD4 delivers 180.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)