Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED WU-180 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WU-180 is a 180.0 W STC (159.7 W PTC) Multi-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 12.2% efficiency, 32.0 V Voc at 25 C, and 36.01 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
180.0 W
PTC Wattage
159.7 W
Voc @ 25C
32.0 V
Efficiency
12.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WU-180 Compare Against Peer CEC Listings?

Engineering position of WAAREE ENERGIES LIMITED WU-180 (180.0 W STC) vs. Mitsubishi Electric PV-MF180UD4 across 1,407 CEC Multi-c-Si solar modules.

Ranking #21,232 across 21,677 CEC solar panels (below all-CEC median; higher than 1.8% of peers), WAAREE ENERGIES LIMITED WU-180 operates as a compact residential or specialty off-grid module sitting 98.8 W below the 278.8 W Multi-c-Si median. Lower 32.0 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters. With typical 88.7% PTC-to-STC thermal output (159.7 W real-world rating), 45 panels occupy 714 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does WAAREE ENERGIES LIMITED WU-180 Fall Across Listed CEC Models?

Plots WAAREE ENERGIES LIMITED WU-180 at 180.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WU-180 (180.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 180.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-180?

Benchmarks WAAREE ENERGIES LIMITED WU-180 on STC wattage, thermal PTC/STC retention, and 12.2 aperture conversion efficiency against CEC peers.

WAAREE ENERGIES LIMITED WU-180 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WU-180 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage180.0 WPTC/STC Retention88.7%Module Efficiency12.2%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-180?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for WAAREE ENERGIES LIMITED WU-180 by WAAREE ENERGIES LIMITED.

Rank #21,232 / 21,677

180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,561

12.2% Aperture Efficiency

Power density 122.0 W/m2 (7.71 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 36.01 V at -10 C (576.2 V string) and 37.16 V at -20 C (16 max).

8 kW Reference Array

45 Panels = 8,100 W STC

Occupies 66.4 m2 (714 sq ft) producing 7,186 W PTC; NEC 690.8 OCPD floor is 12.17 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 32.0 * (1 + (-0.358/100) * (-10 - 25)) = 36.01 V | OCPD = 1.56 * 7.8 = 12.17 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-180: Voc=32.0 V, beta_Voc=-0.358%/C, Isc=7.8 A, STC=180.0 W, Area=1.475 m2.

Result: 16 panels max on 600 V (576.2 V); 45 panels for 8 kW (714 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-180?

Laboratory test ratings recorded for WAAREE ENERGIES LIMITED WU-180 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WU-180.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 180.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 159.7 W (88.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 32.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.8 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 26.0 V / 6.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.358 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.2% (1.475 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WU-180 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (714 sq ft at 8 kW), and estimated Year-1 electric bill offset for WAAREE ENERGIES LIMITED WU-180.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 34 6.12 kW 540 sq ft $1,532 $2,590
8 kW Class 45 8.1 kW 714 sq ft $2,027 $3,428
10 kW Class 56 10.08 kW 889 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Sibling wattage bins and frame colors grouped with WAAREE ENERGIES LIMITED WU-180 under WAAREE ENERGIES LIMITED to prevent duplicate spec pages.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WU-180 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WU-175 175.0 W 155.1 W 32.0 V 26.0 V 11.86%
WAAREE ENERGIES LIMITED WU-180 180.0 W 159.7 W 32.0 V 26.0 V 12.2%

How Many WAAREE ENERGIES LIMITED WU-180 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for WAAREE ENERGIES LIMITED WU-180 (beta_Voc -0.358%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=32.0V and beta_Voc=-0.358%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 37.16 V 16 panels 594.6 V 26 panels
-10 C (14 F) 36.01 V 16 panels 576.2 V 27 panels
0 C (32 F) 34.86 V 17 panels 592.6 V 28 panels
25 C (77 F STC) 32.0 V 18 panels 576.0 V 31 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-180?

Closest cross-brand CEC competitors to WAAREE ENERGIES LIMITED WU-180 matched near 180.0 W STC and 32.0 V Voc, led by Mitsubishi Electric PV-MF180UD4.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Mitsubishi Electric PV-MF180UD4
Mitsubishi Electric
180.0 W Tie (0 W) 30.4 V 13.0% 89.3%
Hanwha Qcells (Qidong) Co Ltd SF190-27-P185
Hanwha Qcells (Qidong) Co Ltd
185.0 W +5.0 W 32.5 V 12.38% 88.6%
Gintung Energy ASEC-180G6S
Gintung Energy
180.0 W Tie (0 W) 29.73 V 13.8% 88.7%
APOS Energy AP180
APOS Energy
180.0 W Tie (0 W) 29.72 V 13.42% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-180?

Evaluate WAAREE ENERGIES LIMITED WU-180 (180.0 W STC, 32.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-180 reaches 37.16 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 45 panels for an 8 kW build require 714 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (714 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-180 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WU-180 8 kW Residential Fit

Needs 45 modules (714 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare Mitsubishi Electric PV-MF180UD4.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 159.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WU-180 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

How many WAAREE ENERGIES LIMITED WU-180 panels fit on a 600 V winter solar string?

At -10 C (14 F), WAAREE ENERGIES LIMITED WU-180 cold Voc rises from 32.0 V to 36.01 V (beta_Voc -0.358%/C), capping a 600 V string at 16 panels (576.2 V).

How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED WU-180 need?

An 8 kW DC system uses 45 WAAREE ENERGIES LIMITED WU-180 modules (8,100 W STC / 7,186 W PTC), covering roughly 714 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does WAAREE ENERGIES LIMITED WU-180 compare against Mitsubishi Electric PV-MF180UD4?

WAAREE ENERGIES LIMITED WU-180 outputs 180.0 W STC (32.0 V Voc, rank #21,232 of 21,677), while Mitsubishi Electric PV-MF180UD4 delivers 180.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.