APOS Energy AP180 is a 180.0 W STC (160.0 W PTC) Multi-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 13.42% efficiency, 29.72 V Voc at 25 C, and 32.8 V cold Voc at -10 C (18 panels max per 600 V string).
- STC Wattage
- 180.0 W
- PTC Wattage
- 160.0 W
- Voc @ 25C
- 29.72 V
- Efficiency
- 13.42%
How Does APOS Energy AP180 Compare Against Peer CEC Listings?
How APOS Energy APOS Energy AP180 handles rooftop heat (160.0 W PTC), 8 kW sizing, and cold winter string voltage.
APOS Energy builds the APOS Energy AP180 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 134.2 W/m2 (6.49 percentage points below 19.91% CEC median). Compared against Gintung Energy ASEC-180G6S (180.0 W), this model holds typical 88.9% PTC-to-STC thermal output (160.0 W real-world rating). Lower 29.72 V string voltage fits 18 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 12.43 A overcurrent floor served by a 15 A breaker.
Where Does APOS Energy AP180 Fall Across Listed CEC Models?
Where APOS Energy AP180 (180.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define APOS Energy AP180?
Percentile placement of APOS Energy AP180 across power density (134.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for APOS Energy AP180?
Four critical engineering numbers homeowners and solar installers check first when reviewing APOS Energy AP180 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
180.0 W STC · Higher Than 1.8%
180.0 W STC (-205.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.42% Aperture Efficiency
Power density 134.2 W/m2 (6.49 percentage points below 19.91% CEC median). PTC/STC ratio: 88.9% (rank #20,819).
18 Panels Max @ -10 C (600 V)
Cold Voc reaches 32.8 V at -10 C (590.4 V string) and 33.68 V at -20 C (17 max).
45 Panels = 8,100 W STC
Occupies 60.3 m2 (650 sq ft) producing 7,200 W PTC; NEC 690.8 OCPD floor is 12.43 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 29.72 * (1 + (-0.296/100) * (-10 - 25)) = 32.8 V | OCPD = 1.56 * 7.97 = 12.43 A
Inputs from CEC Modules.csv for APOS Energy AP180: Voc=29.72 V, beta_Voc=-0.296%/C, Isc=7.97 A, STC=180.0 W, Area=1.341 m2.
Result: 18 panels max on 600 V (590.4 V); 45 panels for 8 kW (650 sq ft).
What Are the Published CEC Specifications for APOS Energy AP180?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for APOS Energy AP180.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 180.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 160.0 W (88.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 29.72 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.97 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 23.58 V / 7.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.296 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.42% (1.341 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Multi-c-Si) | Monofacial backsheet |
How Many APOS Energy AP180 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using APOS Energy AP180 (180.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 34 | 6.12 kW | 491 sq ft | $1,532 | $2,590 |
| 8 kW Class | 45 | 8.1 kW | 650 sq ft | $2,027 | $3,428 |
| 10 kW Class | 56 | 10.08 kW | 808 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This APOS Energy Series?
All closely matched APOS Energy wattages and cosmetic trims sharing the APOS Energy AP180 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| APOS Energy AP175 | 175.0 W | 155.4 W | 29.52 V | 23.31 V | 13.05% |
| APOS Energy AP180 | 180.0 W | 160.0 W | 29.72 V | 23.58 V | 13.42% |
| APOS Energy AP185 | 185.0 W | 164.5 W | 29.86 V | 23.9 V | 13.8% |
How Many APOS Energy AP180 Modules Fit in a Cold-Weather String?
Maximum series module counts for APOS Energy AP180 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 33.68 V | 17 panels | 572.6 V | 29 panels |
| -10 C (14 F) | 32.8 V | 18 panels | 590.4 V | 30 panels |
| 0 C (32 F) | 31.92 V | 18 panels | 574.6 V | 31 panels |
| 25 C (77 F STC) | 29.72 V | 20 panels | 594.4 V | 33 panels |
Which Cross-Brand Solar Modules Compare Closest to APOS Energy AP180?
Alternative CEC solar modules from competing brands near APOS Energy AP180 (180.0 W), including Gintung Energy ASEC-180G6S. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-180G6S Gintung Energy |
180.0 W | Tie (0 W) | 29.73 V | 13.8% | 88.7% |
| Gintung Energy ASEC-180G6M Gintung Energy |
180.0 W | Tie (0 W) | 29.51 V | 13.8% | 89.2% |
| Lightway Green New Energy LW180(23)P1310x990 Lightway Green New Energy |
180.0 W | Tie (0 W) | 29.5 V | 14.02% | 89.5% |
| Yingli Energy (China) YL180P-23b Yingli Energy (China) |
180.0 W | Tie (0 W) | 29.5 V | 14.02% | 90.8% |
What Are the Design Limits and Best-Fit Uses for APOS Energy AP180?
Evaluate APOS Energy AP180 (180.0 W STC, 29.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), APOS Energy AP180 reaches 33.68 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 45 panels for an 8 kW build require 650 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (650 sq ft).
- 2026 tax credit baseline: cash residential installs of APOS Energy AP180 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
APOS Energy AP180 8 kW Residential Fit
Needs 45 modules (650 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 18 panels (-10 C) or 17 panels (-20 C), or compare Gintung Energy ASEC-180G6S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 160.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for APOS Energy AP180 by APOS Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for APOS Energy AP180?
Multiplying APOS Energy AP180's 7.97 A short-circuit current by 1.56 equals 12.43 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can APOS Energy AP180 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 32.8 V cold Voc at 14 F and handles 7.97 A Isc; string inverters cap APOS Energy AP180 at 18 panels on 600 V.
Is APOS Energy AP180 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of APOS Energy AP180 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)