APOS Energy AP180 — CEC Solar Module Specifications

Manufacturer: APOS Energy Registry: CEC Verified Engineering Specification

APOS Energy AP180 is a 180.0 W STC (160.0 W PTC) Multi-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 13.42% efficiency, 29.72 V Voc at 25 C, and 32.8 V cold Voc at -10 C (18 panels max per 600 V string).

STC Wattage
180.0 W
PTC Wattage
160.0 W
Voc @ 25C
29.72 V
Efficiency
13.42%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does APOS Energy AP180 Compare Against Peer CEC Listings?

How APOS Energy APOS Energy AP180 handles rooftop heat (160.0 W PTC), 8 kW sizing, and cold winter string voltage.

APOS Energy builds the APOS Energy AP180 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 134.2 W/m2 (6.49 percentage points below 19.91% CEC median). Compared against Gintung Energy ASEC-180G6S (180.0 W), this model holds typical 88.9% PTC-to-STC thermal output (160.0 W real-world rating). Lower 29.72 V string voltage fits 18 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 12.43 A overcurrent floor served by a 15 A breaker.

Where Does APOS Energy AP180 Fall Across Listed CEC Models?

Where APOS Energy AP180 (180.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where APOS Energy AP180 (180.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAPOS Energy AP180: 180.0 W

What Dataset Percentiles Define APOS Energy AP180?

Percentile placement of APOS Energy AP180 across power density (134.2 W/m2), thermal retention, and nameplate STC wattage.

APOS Energy AP180 Engineering BenchmarksPercentile comparison of APOS Energy AP180 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage180.0 WPTC/STC Retention88.9%Module Efficiency13.42%

What Do the Dataset Ranks Show for APOS Energy AP180?

Four critical engineering numbers homeowners and solar installers check first when reviewing APOS Energy AP180 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #21,232 / 21,677

180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,244

13.42% Aperture Efficiency

Power density 134.2 W/m2 (6.49 percentage points below 19.91% CEC median). PTC/STC ratio: 88.9% (rank #20,819).

NEC 690.7 Limit

18 Panels Max @ -10 C (600 V)

Cold Voc reaches 32.8 V at -10 C (590.4 V string) and 33.68 V at -20 C (17 max).

8 kW Reference Array

45 Panels = 8,100 W STC

Occupies 60.3 m2 (650 sq ft) producing 7,200 W PTC; NEC 690.8 OCPD floor is 12.43 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.72 * (1 + (-0.296/100) * (-10 - 25)) = 32.8 V | OCPD = 1.56 * 7.97 = 12.43 A

Inputs from CEC Modules.csv for APOS Energy AP180: Voc=29.72 V, beta_Voc=-0.296%/C, Isc=7.97 A, STC=180.0 W, Area=1.341 m2.

Result: 18 panels max on 600 V (590.4 V); 45 panels for 8 kW (650 sq ft).

What Are the Published CEC Specifications for APOS Energy AP180?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for APOS Energy AP180.

Official California Energy Commission (NREL SAM) test parameters for APOS Energy AP180.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 180.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 160.0 W (88.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 29.72 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.97 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 23.58 V / 7.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.296 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.42% (1.341 m2) Array roof footprint density
Cell Count & Technology 48 cells (Multi-c-Si) Monofacial backsheet

How Many APOS Energy AP180 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using APOS Energy AP180 (180.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 34 6.12 kW 491 sq ft $1,532 $2,590
8 kW Class 45 8.1 kW 650 sq ft $2,027 $3,428
10 kW Class 56 10.08 kW 808 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This APOS Energy Series?

All closely matched APOS Energy wattages and cosmetic trims sharing the APOS Energy AP180 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the APOS Energy AP180 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
APOS Energy AP175 175.0 W 155.4 W 29.52 V 23.31 V 13.05%
APOS Energy AP180 180.0 W 160.0 W 29.72 V 23.58 V 13.42%
APOS Energy AP185 185.0 W 164.5 W 29.86 V 23.9 V 13.8%

How Many APOS Energy AP180 Modules Fit in a Cold-Weather String?

Maximum series module counts for APOS Energy AP180 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=29.72V and beta_Voc=-0.296%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 33.68 V 17 panels 572.6 V 29 panels
-10 C (14 F) 32.8 V 18 panels 590.4 V 30 panels
0 C (32 F) 31.92 V 18 panels 574.6 V 31 panels
25 C (77 F STC) 29.72 V 20 panels 594.4 V 33 panels

Which Cross-Brand Solar Modules Compare Closest to APOS Energy AP180?

Alternative CEC solar modules from competing brands near APOS Energy AP180 (180.0 W), including Gintung Energy ASEC-180G6S. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-180G6S
Gintung Energy
180.0 W Tie (0 W) 29.73 V 13.8% 88.7%
Gintung Energy ASEC-180G6M
Gintung Energy
180.0 W Tie (0 W) 29.51 V 13.8% 89.2%
Lightway Green New Energy LW180(23)P1310x990
Lightway Green New Energy
180.0 W Tie (0 W) 29.5 V 14.02% 89.5%
Yingli Energy (China) YL180P-23b
Yingli Energy (China)
180.0 W Tie (0 W) 29.5 V 14.02% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for APOS Energy AP180?

Evaluate APOS Energy AP180 (180.0 W STC, 29.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), APOS Energy AP180 reaches 33.68 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 45 panels for an 8 kW build require 650 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (650 sq ft).
  • 2026 tax credit baseline: cash residential installs of APOS Energy AP180 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

APOS Energy AP180 8 kW Residential Fit

Needs 45 modules (650 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 18 panels (-10 C) or 17 panels (-20 C), or compare Gintung Energy ASEC-180G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 160.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for APOS Energy AP180 by APOS Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for APOS Energy AP180?

Multiplying APOS Energy AP180's 7.97 A short-circuit current by 1.56 equals 12.43 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can APOS Energy AP180 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 32.8 V cold Voc at 14 F and handles 7.97 A Isc; string inverters cap APOS Energy AP180 at 18 panels on 600 V.

Is APOS Energy AP180 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of APOS Energy AP180 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.