Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED Bi-68-655 is a 655.0 W STC (610.4 W PTC) Mono-c-Si solar module ranking #463 of 21,677 CEC listings (top 2.4%; higher than 97.6% of peers). It delivers 21.83% efficiency, 46.26 V Voc at 25 C, and 51.81 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
655.0 W
PTC Wattage
610.4 W
Voc @ 25C
46.26 V
Efficiency
21.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED Bi-68-655 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED Bi-68-655 handles rooftop heat (610.4 W PTC), 8 kW sizing, and cold winter string voltage.

WAAREE ENERGIES LIMITED builds the WAAREE ENERGIES LIMITED Bi-68-655 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 218.3 W/m2 (1.92 percentage points above 19.91% CEC median). Compared against Trina Solar CoLtd TSM-660NEG21C20 (660.0 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Mid-range 46.26 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 27.92 A overcurrent floor served by a 30 A breaker.

Where Does WAAREE ENERGIES LIMITED Bi-68-655 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED Bi-68-655 (655.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED Bi-68-655 (655.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 655.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED Bi-68-655?

Percentile placement of WAAREE ENERGIES LIMITED Bi-68-655 across power density (218.3 W/m2), thermal retention, and nameplate STC wattage.

WAAREE ENERGIES LIMITED Bi-68-655 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED Bi-68-655 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage655.0 WPTC/STC Retention93.2%Module Efficiency21.83%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED Bi-68-655?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED Bi-68-655 specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #463 / 21,677

Top 2.4% STC Output

655.0 W STC (+270.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,538

21.83% Aperture Efficiency

Power density 218.3 W/m2 (1.92 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.81 V at -10 C (569.9 V string) and 53.4 V at -20 C (11 max).

8 kW Reference Array

13 Panels = 8,515 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,935 W PTC; NEC 690.8 OCPD floor is 27.92 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.26 * (1 + (-0.343/100) * (-10 - 25)) = 51.81 V | OCPD = 1.56 * 17.9 = 27.92 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED Bi-68-655: Voc=46.26 V, beta_Voc=-0.343%/C, Isc=17.9 A, STC=655.0 W, Area=3.0 m2.

Result: 11 panels max on 600 V (569.9 V); 13 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED Bi-68-655?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED Bi-68-655.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED Bi-68-655.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 655.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 610.4 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 17.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.94 V / 17.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.343 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.83% (3.0 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED Bi-68-655 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED Bi-68-655 (655.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.55 kW 323 sq ft $1,639 $2,772
8 kW Class 13 8.52 kW 420 sq ft $2,132 $3,606
10 kW Class 16 10.48 kW 517 sq ft $2,623 $4,435

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED Bi-68-655 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED Bi-68-655 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED Bi-68-650 650.0 W 605.7 W 46.09 V 37.91 V 21.67%
WAAREE ENERGIES LIMITED Bi-68-655 655.0 W 610.4 W 46.26 V 37.94 V 21.83%
WAAREE ENERGIES LIMITED Bi-68-660 660.0 W 615.2 W 46.4 V 38.06 V 22.0%

How Many WAAREE ENERGIES LIMITED Bi-68-655 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED Bi-68-655 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.26V and beta_Voc=-0.343%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.4 V 11 panels 587.4 V 18 panels
-10 C (14 F) 51.81 V 11 panels 569.9 V 19 panels
0 C (32 F) 50.23 V 11 panels 552.5 V 19 panels
25 C (77 F STC) 46.26 V 12 panels 555.1 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED Bi-68-655?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED Bi-68-655 (655.0 W), including Trina Solar CoLtd TSM-660NEG21C20.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Trina Solar CoLtd TSM-660NEG21C20
Trina Solar CoLtd
660.0 W +5.0 W 46.6 V 21.43% 94.6%
Trina Solar TSM-660DEG21C20
Trina Solar
660.0 W +5.0 W 45.9 V 21.43% 94.4%
Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-660
Chint New Energy Technology Co Ltd
660.0 W +5.0 W 45.89 V 21.78% 92.9%
Risen Energy Co Ltd RSM132-8-660BMDG
Risen Energy Co Ltd
660.0 W +5.0 W 45.89 V 22.68% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED Bi-68-655?

Evaluate WAAREE ENERGIES LIMITED Bi-68-655 (655.0 W STC, 46.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED Bi-68-655 reaches 53.4 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 420 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED Bi-68-655 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED Bi-68-655 8 kW Residential Fit

Needs 13 modules (420 sq ft) with a 30 A string OCPD, offsetting ~$2,132/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Trina Solar CoLtd TSM-660NEG21C20.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 610.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED Bi-68-655 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED Bi-68-655?

Multiplying WAAREE ENERGIES LIMITED Bi-68-655's 17.9 A short-circuit current by 1.56 equals 27.92 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED Bi-68-655 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.81 V cold Voc at 14 F and handles 17.9 A Isc; string inverters cap WAAREE ENERGIES LIMITED Bi-68-655 at 11 panels on 600 V.

Is WAAREE ENERGIES LIMITED Bi-68-655 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED Bi-68-655 rely on utility bill offset (~$2,132/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.