Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED BiN-02-635 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED BiN-02-635 is a 635.0 W STC (602.5 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 22.68% efficiency, 43.74 V Voc at 25 C, and 47.4 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
635.0 W
PTC Wattage
602.5 W
Voc @ 25C
43.74 V
Efficiency
22.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED BiN-02-635 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED BiN-02-635 handles rooftop heat (602.5 W PTC), 8 kW sizing, and cold winter string voltage.

WAAREE ENERGIES LIMITED builds the WAAREE ENERGIES LIMITED BiN-02-635 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 226.8 W/m2 (2.77 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS7L-635TB-AG (635.0 W), this model holds strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Mid-range 43.74 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 28.55 A overcurrent floor served by a 30 A breaker.

Where Does WAAREE ENERGIES LIMITED BiN-02-635 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 635.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED BiN-02-635?

Percentile placement of WAAREE ENERGIES LIMITED BiN-02-635 across power density (226.8 W/m2), thermal retention, and nameplate STC wattage.

WAAREE ENERGIES LIMITED BiN-02-635 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED BiN-02-635 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage635.0 WPTC/STC Retention94.9%Module Efficiency22.68%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED BiN-02-635?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED BiN-02-635 specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #710 / 21,677

Top 3.6% STC Output

635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,656

22.68% Aperture Efficiency

Power density 226.8 W/m2 (2.77 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.4 V at -10 C (568.8 V string) and 48.44 V at -20 C (12 max).

8 kW Reference Array

13 Panels = 8,255 W STC

Occupies 36.4 m2 (392 sq ft) producing 7,832 W PTC; NEC 690.8 OCPD floor is 28.55 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.74 * (1 + (-0.239/100) * (-10 - 25)) = 47.4 V | OCPD = 1.56 * 18.3 = 28.55 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED BiN-02-635: Voc=43.74 V, beta_Voc=-0.239%/C, Isc=18.3 A, STC=635.0 W, Area=2.8 m2.

Result: 12 panels max on 600 V (568.8 V); 13 panels for 8 kW (392 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED BiN-02-635?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED BiN-02-635.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED BiN-02-635.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 635.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 602.5 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.74 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.3 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.77 V / 17.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.239 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.68% (2.8 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED BiN-02-635 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.35 kW 301 sq ft $1,589 $2,687
8 kW Class 13 8.26 kW 392 sq ft $2,067 $3,496
10 kW Class 16 10.16 kW 482 sq ft $2,543 $4,300

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED BiN-02-635 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED BiN-02-635 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED BiN-02-625 625.0 W 592.8 W 43.44 V 36.36 V 22.32%
WAAREE ENERGIES LIMITED BiN-02-630 630.0 W 597.7 W 43.56 V 36.56 V 22.5%
WAAREE ENERGIES LIMITED BiN-02-635 635.0 W 602.5 W 43.74 V 36.77 V 22.68%
WAAREE ENERGIES LIMITED BiN-02-640 640.0 W 607.4 W 43.86 V 36.97 V 22.86%
WAAREE ENERGIES LIMITED BiN-02-645 645.0 W 612.2 W 43.98 V 37.18 V 23.04%

How Many WAAREE ENERGIES LIMITED BiN-02-635 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED BiN-02-635 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.74V and beta_Voc=-0.239%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 48.44 V 12 panels 581.3 V 20 panels
-10 C (14 F) 47.4 V 12 panels 568.8 V 21 panels
0 C (32 F) 46.35 V 12 panels 556.2 V 21 panels
25 C (77 F STC) 43.74 V 13 panels 568.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED BiN-02-635?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W), including CSI Solar Co Ltd CS7L-635TB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS7L-635TB-AG
CSI Solar Co Ltd
635.0 W Tie (0 W) 43.5 V 23.09% 94.9%
CSI Solar Co Ltd CS7N-640MB-AG
CSI Solar Co Ltd
640.0 W +5.0 W 44.6 V 20.85% 93.1%
Hanersun Energy Co Ltd HN21-66HT640W
Hanersun Energy Co Ltd
640.0 W +5.0 W 44.6 V 21.12% 94.4%
Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-640
Chint New Energy Technology Co Ltd
640.0 W +5.0 W 45.09 V 21.12% 92.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED BiN-02-635?

Evaluate WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W STC, 43.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED BiN-02-635 reaches 48.44 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 392 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED BiN-02-635 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED BiN-02-635 8 kW Residential Fit

Needs 13 modules (392 sq ft) with a 30 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS7L-635TB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 602.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED BiN-02-635 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED BiN-02-635?

Multiplying WAAREE ENERGIES LIMITED BiN-02-635's 18.3 A short-circuit current by 1.56 equals 28.55 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED BiN-02-635 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 47.4 V cold Voc at 14 F and handles 18.3 A Isc; string inverters cap WAAREE ENERGIES LIMITED BiN-02-635 at 12 panels on 600 V.

Is WAAREE ENERGIES LIMITED BiN-02-635 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED BiN-02-635 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.