WAAREE ENERGIES LIMITED BiN-02-635 is a 635.0 W STC (602.5 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 22.68% efficiency, 43.74 V Voc at 25 C, and 47.4 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 635.0 W
- PTC Wattage
- 602.5 W
- Voc @ 25C
- 43.74 V
- Efficiency
- 22.68%
How Does WAAREE ENERGIES LIMITED BiN-02-635 Compare Against Peer CEC Listings?
How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED BiN-02-635 handles rooftop heat (602.5 W PTC), 8 kW sizing, and cold winter string voltage.
WAAREE ENERGIES LIMITED builds the WAAREE ENERGIES LIMITED BiN-02-635 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 226.8 W/m2 (2.77 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS7L-635TB-AG (635.0 W), this model holds strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Mid-range 43.74 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 28.55 A overcurrent floor served by a 30 A breaker.
Where Does WAAREE ENERGIES LIMITED BiN-02-635 Fall Across Listed CEC Models?
Where WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED BiN-02-635?
Percentile placement of WAAREE ENERGIES LIMITED BiN-02-635 across power density (226.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED BiN-02-635?
Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED BiN-02-635 specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Top 3.6% STC Output
635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.68% Aperture Efficiency
Power density 226.8 W/m2 (2.77 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.4 V at -10 C (568.8 V string) and 48.44 V at -20 C (12 max).
13 Panels = 8,255 W STC
Occupies 36.4 m2 (392 sq ft) producing 7,832 W PTC; NEC 690.8 OCPD floor is 28.55 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.74 * (1 + (-0.239/100) * (-10 - 25)) = 47.4 V | OCPD = 1.56 * 18.3 = 28.55 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED BiN-02-635: Voc=43.74 V, beta_Voc=-0.239%/C, Isc=18.3 A, STC=635.0 W, Area=2.8 m2.
Result: 12 panels max on 600 V (568.8 V); 13 panels for 8 kW (392 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED BiN-02-635?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED BiN-02-635.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 635.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 602.5 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.74 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.3 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.77 V / 17.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.239 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.68% (2.8 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many WAAREE ENERGIES LIMITED BiN-02-635 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.35 kW | 301 sq ft | $1,589 | $2,687 |
| 8 kW Class | 13 | 8.26 kW | 392 sq ft | $2,067 | $3,496 |
| 10 kW Class | 16 | 10.16 kW | 482 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?
All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED BiN-02-635 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| WAAREE ENERGIES LIMITED BiN-02-625 | 625.0 W | 592.8 W | 43.44 V | 36.36 V | 22.32% |
| WAAREE ENERGIES LIMITED BiN-02-630 | 630.0 W | 597.7 W | 43.56 V | 36.56 V | 22.5% |
| WAAREE ENERGIES LIMITED BiN-02-635 | 635.0 W | 602.5 W | 43.74 V | 36.77 V | 22.68% |
| WAAREE ENERGIES LIMITED BiN-02-640 | 640.0 W | 607.4 W | 43.86 V | 36.97 V | 22.86% |
| WAAREE ENERGIES LIMITED BiN-02-645 | 645.0 W | 612.2 W | 43.98 V | 37.18 V | 23.04% |
How Many WAAREE ENERGIES LIMITED BiN-02-635 Modules Fit in a Cold-Weather String?
Maximum series module counts for WAAREE ENERGIES LIMITED BiN-02-635 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.44 V | 12 panels | 581.3 V | 20 panels |
| -10 C (14 F) | 47.4 V | 12 panels | 568.8 V | 21 panels |
| 0 C (32 F) | 46.35 V | 12 panels | 556.2 V | 21 panels |
| 25 C (77 F STC) | 43.74 V | 13 panels | 568.6 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED BiN-02-635?
Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W), including CSI Solar Co Ltd CS7L-635TB-AG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS7L-635TB-AG CSI Solar Co Ltd |
635.0 W | Tie (0 W) | 43.5 V | 23.09% | 94.9% |
| CSI Solar Co Ltd CS7N-640MB-AG CSI Solar Co Ltd |
640.0 W | +5.0 W | 44.6 V | 20.85% | 93.1% |
| Hanersun Energy Co Ltd HN21-66HT640W Hanersun Energy Co Ltd |
640.0 W | +5.0 W | 44.6 V | 21.12% | 94.4% |
| Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-640 Chint New Energy Technology Co Ltd |
640.0 W | +5.0 W | 45.09 V | 21.12% | 92.8% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED BiN-02-635?
Evaluate WAAREE ENERGIES LIMITED BiN-02-635 (635.0 W STC, 43.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED BiN-02-635 reaches 48.44 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 392 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED BiN-02-635 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED BiN-02-635 8 kW Residential Fit
Needs 13 modules (392 sq ft) with a 30 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS7L-635TB-AG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 602.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED BiN-02-635 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED BiN-02-635?
Multiplying WAAREE ENERGIES LIMITED BiN-02-635's 18.3 A short-circuit current by 1.56 equals 28.55 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can WAAREE ENERGIES LIMITED BiN-02-635 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 47.4 V cold Voc at 14 F and handles 18.3 A Isc; string inverters cap WAAREE ENERGIES LIMITED BiN-02-635 at 12 panels on 600 V.
Is WAAREE ENERGIES LIMITED BiN-02-635 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED BiN-02-635 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)