Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED BiN-03-690 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED BiN-03-690 is a 690.0 W STC (654.3 W PTC) Mono-c-Si solar module ranking #249 of 21,677 CEC listings (top 1.3%; higher than 98.7% of peers). It delivers 22.4% efficiency, 47.8 V Voc at 25 C, and 51.83 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
690.0 W
PTC Wattage
654.3 W
Voc @ 25C
47.8 V
Efficiency
22.4%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED BiN-03-690 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED BiN-03-690: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 690.0 W STC and 654.3 W PTC, WAAREE ENERGIES LIMITED BiN-03-690 sits +305.0 W vs all-CEC median (top 1.3%; higher than 98.7% of peers) among 21,677 listed modules. Power density reaches 224.0 W/m2 (2.49 percentage points above 19.91% CEC median). Mid-range 47.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Thornova Solar TS-BGT66(690)-G12 rates 690.0 W.

Where Does WAAREE ENERGIES LIMITED BiN-03-690 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED BiN-03-690 (690.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED BiN-03-690 (690.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 690.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED BiN-03-690?

Dataset percentiles tracking WAAREE ENERGIES LIMITED BiN-03-690 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED BiN-03-690 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED BiN-03-690 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage690.0 WPTC/STC Retention94.8%Module Efficiency22.4%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED BiN-03-690?

Benchmark highlights for WAAREE ENERGIES LIMITED BiN-03-690 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #249 / 21,677

Top 1.3% STC Output

690.0 W STC (+305.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,240

22.4% Aperture Efficiency

Power density 224.0 W/m2 (2.49 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.83 V at -10 C (570.1 V string) and 52.98 V at -20 C (11 max).

8 kW Reference Array

12 Panels = 8,280 W STC

Occupies 37.0 m2 (398 sq ft) producing 7,852 W PTC; NEC 690.8 OCPD floor is 28.45 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.8 * (1 + (-0.241/100) * (-10 - 25)) = 51.83 V | OCPD = 1.56 * 18.24 = 28.45 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED BiN-03-690: Voc=47.8 V, beta_Voc=-0.241%/C, Isc=18.24 A, STC=690.0 W, Area=3.08 m2.

Result: 11 panels max on 600 V (570.1 V); 12 panels for 8 kW (398 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED BiN-03-690?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED BiN-03-690 (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED BiN-03-690.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 690.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 654.3 W (94.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.09 V / 17.21 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.4% (3.08 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED BiN-03-690 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED BiN-03-690 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 9 6.21 kW 298 sq ft $1,554 $2,628
8 kW Class 12 8.28 kW 398 sq ft $2,072 $3,504
10 kW Class 15 10.35 kW 497 sq ft $2,591 $4,380

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED BiN-03-690 mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED BiN-03-690 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED BiN-03-680 680.0 W 644.6 W 47.55 V 39.67 V 22.08%
WAAREE ENERGIES LIMITED BiN-03-685 685.0 W 649.4 W 47.7 V 39.87 V 22.24%
WAAREE ENERGIES LIMITED BiN-03-690 690.0 W 654.3 W 47.8 V 40.09 V 22.4%
WAAREE ENERGIES LIMITED BiN-03-695 695.0 W 659.1 W 48.0 V 40.29 V 22.56%

How Many WAAREE ENERGIES LIMITED BiN-03-690 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED BiN-03-690 (51.83 V at 14 F).

Computed from Voc=47.8V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.98 V 11 panels 582.8 V 18 panels
-10 C (14 F) 51.83 V 11 panels 570.1 V 19 panels
0 C (32 F) 50.68 V 11 panels 557.5 V 19 panels
25 C (77 F STC) 47.8 V 12 panels 573.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED BiN-03-690?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED BiN-03-690 in nameplate wattage and Voc, starting with Thornova Solar TS-BGT66(690)-G12.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Thornova Solar TS-BGT66(690)-G12
Thornova Solar
690.0 W Tie (0 W) 47.9 V 22.4% 95.0%
Vietnam Sunergy Joint Stock Company VSUN690N-132BMH-DG
Vietnam Sunergy Joint Stock Company
690.0 W Tie (0 W) 47.9 V 22.21% 94.3%
Boviet Solar Technology Co Ltd BVM8611M-690-H-HC-BF
Boviet Solar Technology Co Ltd
690.0 W Tie (0 W) 48.25 V 23.71% 95.2%
Boviet Solar Technology Co Ltd BVM8611M-690-H-HC-BF-DG
Boviet Solar Technology Co Ltd
690.0 W Tie (0 W) 48.25 V 23.71% 95.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED BiN-03-690?

Evaluate WAAREE ENERGIES LIMITED BiN-03-690 (690.0 W STC, 47.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED BiN-03-690 reaches 52.98 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 12 panels for an 8 kW build require 398 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED BiN-03-690 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED BiN-03-690 8 kW Residential Fit

Needs 12 modules (398 sq ft) with a 30 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Thornova Solar TS-BGT66(690)-G12.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 654.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED BiN-03-690 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

How many WAAREE ENERGIES LIMITED BiN-03-690 panels fit on a 600 V winter solar string?

At -10 C (14 F), WAAREE ENERGIES LIMITED BiN-03-690 cold Voc rises from 47.8 V to 51.83 V (beta_Voc -0.241%/C), capping a 600 V string at 11 panels (570.1 V).

How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED BiN-03-690 need?

An 8 kW DC system uses 12 WAAREE ENERGIES LIMITED BiN-03-690 modules (8,280 W STC / 7,852 W PTC), covering roughly 398 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does WAAREE ENERGIES LIMITED BiN-03-690 compare against Thornova Solar TS-BGT66(690)-G12?

WAAREE ENERGIES LIMITED BiN-03-690 outputs 690.0 W STC (47.8 V Voc, rank #249 of 21,677), while Thornova Solar TS-BGT66(690)-G12 delivers 690.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls