Mitsubishi Electric PV-MF170UD4 is a 170.0 W STC (151.6 W PTC) Multi-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 12.28% efficiency, 29.9 V Voc at 25 C, and 33.47 V cold Voc at -10 C (17 panels max per 600 V string).

STC Wattage
170.0 W
PTC Wattage
151.6 W
Voc @ 25C
29.9 V
Efficiency
12.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitsubishi Electric PV-MF170UD4 Compare Against Peer CEC Listings?

How Mitsubishi Electric Mitsubishi Electric PV-MF170UD4 handles rooftop heat (151.6 W PTC), 8 kW sizing, and cold winter string voltage.

Mitsubishi Electric builds the Mitsubishi Electric PV-MF170UD4 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 122.8 W/m2 (7.63 percentage points below 19.91% CEC median). Compared against Lightway Green New Energy LW170(23)P1310x990 (170.0 W), this model holds typical 89.2% PTC-to-STC thermal output (151.6 W real-world rating). Lower 29.9 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 12.21 A overcurrent floor served by a 15 A breaker.

Where Does Mitsubishi Electric PV-MF170UD4 Fall Across Listed CEC Models?

Where Mitsubishi Electric PV-MF170UD4 (170.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitsubishi Electric PV-MF170UD4 (170.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitsubishi Electri: 170.0 W

What Dataset Percentiles Define Mitsubishi Electric PV-MF170UD4?

Percentile placement of Mitsubishi Electric PV-MF170UD4 across power density (122.8 W/m2), thermal retention, and nameplate STC wattage.

Mitsubishi Electric PV-MF170UD4 Engineering BenchmarksPercentile comparison of Mitsubishi Electric PV-MF170UD4 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage170.0 WPTC/STC Retention89.2%Module Efficiency12.28%

What Do the Dataset Ranks Show for Mitsubishi Electric PV-MF170UD4?

Four critical engineering numbers homeowners and solar installers check first when reviewing Mitsubishi Electric PV-MF170UD4 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #21,323 / 21,677

170.0 W STC · Higher Than 1.5%

170.0 W STC (-215.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,552

12.28% Aperture Efficiency

Power density 122.8 W/m2 (7.63 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.47 V at -10 C (569.0 V string) and 34.49 V at -20 C (17 max).

8 kW Reference Array

48 Panels = 8,160 W STC

Occupies 66.4 m2 (715 sq ft) producing 7,277 W PTC; NEC 690.8 OCPD floor is 12.21 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.9 * (1 + (-0.341/100) * (-10 - 25)) = 33.47 V | OCPD = 1.56 * 7.83 = 12.21 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-MF170UD4: Voc=29.9 V, beta_Voc=-0.341%/C, Isc=7.83 A, STC=170.0 W, Area=1.384 m2.

Result: 17 panels max on 600 V (569.0 V); 48 panels for 8 kW (715 sq ft).

What Are the Published CEC Specifications for Mitsubishi Electric PV-MF170UD4?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mitsubishi Electric PV-MF170UD4.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-MF170UD4.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 170.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 151.6 W (89.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 29.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.83 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 23.7 V / 7.19 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.341 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.28% (1.384 m2) Array roof footprint density
Cell Count & Technology 50 cells (Multi-c-Si) Monofacial backsheet

How Many Mitsubishi Electric PV-MF170UD4 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mitsubishi Electric PV-MF170UD4 (170.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 36 6.12 kW 536 sq ft $1,532 $2,590
8 kW Class 48 8.16 kW 715 sq ft $2,042 $3,454
10 kW Class 59 10.03 kW 879 sq ft $2,510 $4,245

How Many Mitsubishi Electric PV-MF170UD4 Modules Fit in a Cold-Weather String?

Maximum series module counts for Mitsubishi Electric PV-MF170UD4 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=29.9V and beta_Voc=-0.341%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 34.49 V 17 panels 586.3 V 28 panels
-10 C (14 F) 33.47 V 17 panels 569.0 V 29 panels
0 C (32 F) 32.45 V 18 panels 584.1 V 30 panels
25 C (77 F STC) 29.9 V 20 panels 598.0 V 33 panels

Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-MF170UD4?

Alternative CEC solar modules from competing brands near Mitsubishi Electric PV-MF170UD4 (170.0 W), including Lightway Green New Energy LW170(23)P1310x990.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Lightway Green New Energy LW170(23)P1310x990
Lightway Green New Energy
170.0 W Tie (0 W) 29.5 V 13.25% 89.4%
Yingli Energy (China) YL170P-23b
Yingli Energy (China)
170.0 W Tie (0 W) 29.0 V 13.24% 90.7%
Lightway Green New Energy LW175(23)P1310x990
Lightway Green New Energy
175.0 W +5.0 W 29.5 V 13.63% 89.4%
Lightway Green New Energy LW165(23)P1310x990
Lightway Green New Energy
165.0 W -5.0 W 29.0 V 10.19% 88.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-MF170UD4?

Evaluate Mitsubishi Electric PV-MF170UD4 (170.0 W STC, 29.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-MF170UD4 reaches 34.49 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 48 panels for an 8 kW build require 715 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (715 sq ft).
  • 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-MF170UD4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitsubishi Electric PV-MF170UD4 8 kW Residential Fit

Needs 48 modules (715 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Lightway Green New Energy LW170(23)P1310x990.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 151.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-MF170UD4 by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Mitsubishi Electric PV-MF170UD4?

Multiplying Mitsubishi Electric PV-MF170UD4's 7.83 A short-circuit current by 1.56 equals 12.21 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Mitsubishi Electric PV-MF170UD4 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 33.47 V cold Voc at 14 F and handles 7.83 A Isc; string inverters cap Mitsubishi Electric PV-MF170UD4 at 17 panels on 600 V.

Is Mitsubishi Electric PV-MF170UD4 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitsubishi Electric PV-MF170UD4 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.